Dickson TM320

Dickson TM320 Temperature and Humidity Data Logger

Manuale di istruzioni

1. Introduzione

The Dickson TM320 is a versatile data logger designed to accurately monitor and record temperature and humidity levels. Featuring a large display for real-time readings, audio/visual alarms, and convenient data transfer options via USB and flash card, it provides essential environmental monitoring for various applications. Its user-friendly design ensures ease of use and reliable performance.

  • USB Enabled Download: Easily transfer recorded data to a computer.
  • Flash Memory Data Transfer Capability: Utilize flash cards for convenient data retrieval.
  • Jumbo Display: Clear and easy-to-read real-time measurements.
  • Facile da usare: Intuitive interface for straightforward operation.

2. Informazioni sulla sicurezza

Please read all safety instructions before operating the device. Failure to do so may result in damage to the device or personal injury.

  • Non esporre il dispositivo a temperature estreme al di fuori dell'intervallo operativo specificato.
  • Avoid direct contact with water or high humidity environments beyond the non-condensing range.
  • Utilizzare solo le fonti di alimentazione e gli accessori specificati.
  • Non tentare di aprire o riparare il dispositivo da soli. Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato.
  • Tenere fuori dalla portata dei bambini.

3. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

  • Dickson TM320 Data Logger
  • Manuale di istruzioni (questo documento)
  • Cavo USB (può essere venduto separatamente)
  • SD Card (may be sold separately)
  • Batteries (may be pre-installed or included)

4. Prodotto finitoview

Davanti view of Dickson TM320 Data Logger with display showing '0.0' and battery indicator.

Figura 4.1: Fronte View. Shows the large digital display, 'DICKSON' branding, and three control buttons: MIN/MAX, ALARM, and SAVE.

Lato view of Dickson TM320 Data Logger showing USB port, sensor input, and ventilation slots.

Figura 4.2: lato View con i porti. Illustrates the mini-USB port for data transfer and external sensor input jacks, along with ventilation for internal sensors.

Indietro view of Dickson TM320 Data Logger showing battery compartment and mounting holes.

Figura 4.3: Indietro View. Displays the battery compartment cover and keyhole slots for wall mounting.

Superiore view of Dickson TM320 Data Logger showing the SD card slot.

Figura 4.4: in alto View. Shows the slot for inserting an SD card for data storage and transfer.

5. Impostazione

5.1. Installazione della batteria

  1. Individuare il vano batteria sul retro del dispositivo (fare riferimento alla Figura 4.3).
  2. Far scorrere il coperchio della batteria aperto.
  3. Insert the required batteries (typically AA or AAA, check compartment for type) ensuring correct polarity (+/-).
  4. Chiudere bene il coperchio della batteria.

5.2. Accensione iniziale

The device should power on automatically once batteries are installed. The display will illuminate, showing current readings or a startup sequence.

5.3. Montaggio del dispositivo

The TM320 can be placed on a flat surface or mounted on a wall:

  • Posizionamento sulla superficie: Ensure the device is placed on a stable, level surface away from direct heat sources or extreme drafts.
  • Montaggio a parete: Use appropriate screws (not included) with the keyhole slots on the back of the device (refer to Figure 4.3) to secure it to a wall. Ensure it is mounted in a location representative of the environment you wish to monitor.

6. Funzionamento

6.1. Comprensione del display

The jumbo display provides real-time information:

  • Lettura attuale: Shows the live temperature or humidity value.
  • Unità: Indicates Fahrenheit (F) or Celsius (C) for temperature, and %RH for humidity.
  • Indicatore della batteria: Visualizza la durata residua della batteria.
  • CH (Canale): Indicates which channel is currently displayed (e.g., CH 1 for temperature, CH 2 for humidity).

6.2. Funzioni dei pulsanti

  • Pulsante MIN/MAX: Press to cycle through minimum, maximum, and current readings for both temperature and humidity. Hold to reset min/max values.
  • Pulsante ALLARME: Premere per view current alarm settings. Hold to enter alarm setting mode (refer to section 6.4).
  • Pulsante SALVA: Press to manually save a data point.

6.3. Registrazione dei dati

The TM320 automatically logs data at a pre-set interval. Data can be viewed on the display or downloaded to a computer.

6.4. Impostazione degli allarmi

The device features audio/visual alarms for out-of-range conditions.

  1. Premere e tenere premuto il tasto ALLARME button until the alarm setting mode is activated.
  2. Utilizzare il MINIMO MASSIMO button to navigate between temperature and humidity alarm settings (high/low).
  3. Utilizzare il SALVA button to adjust the alarm threshold values.
  4. Premere ALLARME nuovamente per confermare e uscire dalla modalità di impostazione.

6.5. Download dei dati (USB)

  1. Connect the TM320 to your computer using a compatible USB cable (refer to Figure 4.2 for port location).
  2. The device should be recognized as a removable storage device or require specific Dickson software (refer to manufacturer's websito per software).
  3. Follow the software instructions to download and analyze the logged data.

6.6. Data Transfer (Flash Card)

If your model supports flash card data recovery:

  1. Insert a compatible SD card into the SD card slot (refer to Figure 4.4).
  2. The device may automatically transfer data or require a specific button press (consult software/manual for details).
  3. Remove the SD card and insert it into a computer's card reader to access the data.

7. Manutenzione

7.1. Pulizia

Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquid enters the sensor vents or ports.

7.2. Sostituzione della batteria

Replace batteries when the low battery indicator appears on the display. Follow the battery installation steps in Section 5.1.

7.3. Conservazione

When not in use for extended periods, remove the batteries and store the device in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Batterie scariche o installate in modo errato.Controllare la polarità delle batterie; sostituirle con batterie nuove.
No data is being logged.Device not powered on; memory full; logging paused.Ensure device is on; download data to clear memory; check software settings for logging status.
Display shows 'Err' or abnormal readings.Sensor malfunction; out of range conditions.Move device to a stable environment; contact support if error persists.
Cannot download data via USB.Incorrect cable; driver issue; software not installed.Ensure correct USB cable; install necessary drivers/software from Dickson websito.
L'allarme non suona.Alarm disabled; volume too low; thresholds set incorrectly.Check alarm settings (Section 6.4); ensure alarm is enabled and thresholds are appropriate.

9. Specifiche

CaratteristicaDettaglio
Numero di modelloTM320
Intervallo di temperaturada -4 a 158°F (da -20 a 70°C)
Umidità ambiente0-95% RH (senza condensa)
ProduttoreDickson Unigage Inc.
Dimensioni del prodotto19.56 x 16.51 x 8.89 cm (7.7 x 6.5 x 3.5 pollici)
Peso del prodotto385.55 g (0.85 libbre)
Trasferimento datiUSB, Flash Card (SD)
DisplayLCD gigante

10. Garanzia e supporto

This product is covered by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the documentation included with your purchase or visit the official Dickson website. For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Dickson customer service through their official channels.

Dickson Official Websito: www.dicksonlogger.com

© 2024 Dickson. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.