Corning 6795-620D
Corning PC-620D Stirring Hot Plate User Manual
Modello: 6795-620D
1. Introduzione
This manual provides essential information for the safe and effective operation, maintenance, and troubleshooting of your Corning PC-620D Stirring Hot Plate. The PC-620D is a laboratory instrument designed for precise temperature control and stirring of various solutions, featuring a durable Pyroceram top and digital displays for both temperature and stirring speed.

Figure 1: Corning PC-620D Stirring Hot Plate. This image shows the hot plate from an angled front view, highlighting the white Pyroceram top, the gray base, and the control panel with digital readouts for stirring speed (RPM) and temperature (Celsius), along with the 'Stir' and 'Heat' control knobs.
2. Informazioni sulla sicurezza
Per evitare lesioni e danni allo strumento, osservare sempre le seguenti precauzioni di sicurezza:
- Superficie calda: The top surface can reach high temperatures. Always allow the unit to cool completely before touching or moving. A "HOT TOP" indicator light will illuminate when the surface temperature exceeds 60°C (140°F).
- Sicurezza elettrica: Connect the unit only to a properly grounded electrical outlet with the specified voltage (120V/60Hz). Do not operate with a damaged power cord.
- Ventilazione: Assicurare un'adeguata ventilazione attorno all'unità per evitare il surriscaldamento.
- Fuoriuscite: In case of spills, immediately disconnect the power and clean the unit carefully after it has cooled. Avoid liquid ingress into the internal components.
- Dispositivi di protezione individuale: Always wear appropriate personal protective equipment (e.g., heat-resistant gloves, eye protection) when operating the hot plate.
- Uso previsto: Use the hot plate only for its intended laboratory heating and stirring applications. Do not use for heating flammable or explosive materials without proper safety protocols.
3. Cosa c'è nella scatola
Upon unpacking, verify that the following item is present:
- One (1) Corning PC-620D Stirring Hot Plate
Se qualche componente risulta mancante o danneggiato, contattare immediatamente il fornitore.
4. Impostazione
- Posizionamento: Place the hot plate on a stable, level, and heat-resistant surface away from flammable materials. Ensure there is sufficient clearance around the unit for air circulation.
- Collegamento elettrico: Connect the power cord to the back of the hot plate and then plug the three-prong plug into a grounded 120V/60Hz electrical outlet.
- Ispezione iniziale: Before first use, inspect the unit for any visible damage from shipping.
5. Funzionamento
5.1 Controlli e Indicatori
- Indicatore di energia: Green light illuminates when the unit is powered on.
- STIR Knob: Controls the stirring speed from 60 to 1150 RPM. Turn clockwise to increase speed.
- STIR RPM Display: Digital LED display shows the current stirring speed in RPM.
- HEAT Knob: Controls the heating temperature from 5°C to 550°C. Turn clockwise to increase temperature.
- TEMPERATURE Display: Digital LED display shows the set temperature in Celsius. It blinks until the set temperature is reached.
- HOT TOP Indicator: Red light illuminates when the top surface temperature exceeds 60°C (140°F), even if the heat function is turned off.
5.2 Funzione di agitazione
- Place a suitable stir bar into your vessel (e.g., beaker, flask) containing the solution.
- Place the vessel centrally on the Pyroceram top.
- Turn the STIR knob clockwise to the desired RPM. The digital display will show the set speed.
- Adjust the speed as needed for optimal mixing without splashing.
- To stop stirring, turn the STIR knob counter-clockwise to the "Off" position.
5.3 Funzione Riscaldamento
- Place your vessel containing the sample on the Pyroceram top.
- Turn the HEAT knob clockwise to the desired temperature. The digital display will show the set temperature in 5°C increments.
- The temperature display will blink until the set temperature is reached, then it will remain steady.
- Monitor the HOT TOP indicator. It will remain lit as long as the surface temperature is above 60°C, even after the heat is turned off.
- To turn off heating, turn the HEAT knob counter-clockwise to the "Off" position. Allow the unit to cool down naturally.
6. Manutenzione e cura
- Pulizia: Disconnect the power cord and allow the unit to cool completely before cleaning. Wipe the Pyroceram top and housing with a damp panno e detergente delicato. Non utilizzare detergenti abrasivi o solventi.
- Fuoriuscite: Clean spills immediately to prevent residue buildup. For chemical spills, refer to appropriate safety data sheets for cleaning procedures.
- Magazzinaggio: Store the hot plate in a clean, dry environment when not in use.
- Ispezione: Periodically inspect the power cord for any signs of damage.
7. Risoluzione Dei Problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'unità non si accende. | No power to outlet; power cord disconnected or damaged. | Check power outlet; ensure power cord is securely connected and undamaged. |
| No stirring action. | Stir knob is off; stir bar not present or not coupled. | Turn stir knob to desired RPM; ensure stir bar is in vessel and centered. |
| Senza riscaldamento. | Heat knob is off; temperature set too low. | Turn heat knob to desired temperature; increase set temperature. |
| Temperature display blinking. | Unit has not reached set temperature. | This is normal operation. Wait for the unit to reach the set temperature. |
8. Specifiche
| Parametro | Valore |
|---|---|
| Numero di modello | 6795-620D |
| Materiale della piastra superiore | Pyroceram Glass-Ceramic |
| Dimensioni della piastra superiore | 10 x 10 pollici (25.4 x 25.4 cm) |
| Intervallo di temperatura | da 5°C a 550°C (da 41°F a 1022°F) |
| Incrementi di temperatura | 5°C |
| Stirring Speed Range | Da 60 a 1150 giri/min |
| Requisiti elettrici | 120V/60Hz |
| Dimensioni complessive (L x P x A) | 19 x 18 x 8 pollici |
| Peso | 11.46 libbre |
| Certificazioni | UL, cUL Approved |
9. Garanzia e supporto
The Corning PC-620D Stirring Hot Plate comes with a Garanzia di 2 anno from the date of purchase, covering defects in materials and workmanship under normal use. For warranty claims, technical support, or service inquiries, please contact Corning customer service or your authorized distributor.
Please have your model number (6795-620D) and purchase information ready when contacting support.
Documenti correlati - 6795-620D
![]() |
Manuale di istruzioni per piastre riscaldanti, agitatori e agitatori/piastre riscaldanti Corning Manuale di istruzioni per piastre riscaldanti, agitatori e piastre riscaldanti/agitatori con display digitale Corning e per il regolatore di temperatura 6795PR. Include istruzioni per l'uso, informazioni sulla sicurezza, specifiche tecniche e dettagli sulla garanzia. |
![]() |
Manuale di istruzioni per piastre riscaldanti, agitatori e agitatori/piastre riscaldanti Corning (120 V) Manuale di istruzioni completo per piastre riscaldanti, agitatori e piastre riscaldanti/agitatori da 120 V Corning (serie PC-200, PC-400, PC-600). Contiene informazioni generali, funzionamento, manutenzione, specifiche e sicurezza. |
![]() |
Corning Permeable Supports Selection Guide: Transwell and Falcon Cell Culture Inserts A comprehensive guide from Corning and Fisher Scientific to select the optimal permeable supports, including Transwell and Falcon cell culture inserts, based on membrane type, pore size, format, and surface treatment for various research applications. |
![]() |
Corning Digital Hot Plates and Stirrers: Precision Laboratory Equipment Discover Corning's Digital Hot Plates and Stirrers, designed for laboratory precision. Features include dual digital displays, accurate temperature control (±2°C), durable Pyroceram® tops, and safety indicators. Explore models like PC-400D, PC-420D, and available accessories. |
![]() |
Corning Laboratory Equipment Product Selection Guide | Pipettors, Centrifuges, Shakers & More Corning Life Sciences presents its Equipment Selection Guide, featuring a comprehensive range of its newest and most requested laboratory products. This guide, available through Fisher Scientific, offers detailed information on essential scientific instruments for research applications, including pipettors, centrifuges, shakers, incubators, hot plates, and more. |
![]() |
Belimo Damper Actuator and Control Valve Wiring Guide Comprehensive wiring guide for Belimo damper actuators and control valves, covering installation, transformer sizing, wire length, and various actuator models for HVAC systems. |
Ask a question about this manual