Broan-NuTone 353

Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan User Manual

Modello: 353

1. Prodotto finitoview

The Broan-NuTone 353 Powered Attic and Garage Ventilation Fan is designed to prevent heat and moisture buildup in attics and garages. Proper ventilation helps maintain a cooler, drier environment, which can extend the lifespan of your roof and air conditioning system, while also reducing energy costs. This fan is suitable for ventilating one, two, or three-car garages, whether attached or detached from the home, effectively combating heat, humidity, and unwanted odors.

Le caratteristiche principali includono:

  • Gable Mount Installation: Specifically designed for gable installation, requiring permanent electrical wiring and grounding. Extension cords must not be used.
  • Funzionamento efficiente: Delivers 760 Cubic Feet Per Minute (CFM) of airflow. Features a precision-balanced 14-inch metal blade for maximum air movement.
  • Costruzione durevole: Constructed with galvanized steel housing for enhanced strength and longevity.
  • Controllo automatico: Equipped with an adjustable, built-in thermostat for automatic operation based on temperature.
  • Dimensioni: Housing measures 15 inches in diameter and 8 inches deep, with a 14-inch diameter steel blade.
Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan

Image 1.1: Broan-NuTone 353 Gable Mount Attic and Garage Ventilation Fan. This image shows the complete fan unit, highlighting its robust construction and blade design.

2. Informazioni sulla sicurezza

AVVERTENZA: per ridurre il rischio di incendi, scosse elettriche o lesioni alle persone, osservare quanto segue:

  • Il lavoro di installazione e il cablaggio elettrico devono essere eseguiti da persone qualificate in conformità con tutti i codici e gli standard applicabili, compresi i codici e gli standard di costruzione antincendio.
  • Prima di effettuare il cablaggio o la manutenzione dell'unità, scollegare sempre l'alimentazione dal pannello di servizio.
  • This unit requires permanent electrical wiring and grounding. Do not use with an electrical extension cord.
  • This product is intended for gable installation only.
  • Avvertenza sulla Proposta 65 della California: Questo prodotto può contenere sostanze chimiche note allo Stato della California come causa di cancro, difetti alla nascita o altri danni riproduttivi.

3. Configurazione e installazione

Proper installation is crucial for the efficient and safe operation of your Broan-NuTone 353 fan. This fan is designed for gable mounting. Ensure you have adequate soffit ventilation to allow for proper airflow.

3.1. Considerazioni pre-installazione

  • Requisiti di ventilazione: Calculate the required Cubic Feet Per Minute (CFM) for your attic or garage. A general guideline is to multiply the attic volume (Length x Width x Height) by 10 air changes per hour, then divide by 60 minutes/hour to get CFM. Ensure sufficient soffit vent area (approximately 0.48 square inches per CFM).
  • Cavi elettrici: The fan requires permanent 120-volt AC electrical wiring and proper grounding. Consult a qualified electrician if you are unsure about electrical connections.
  • Posizione di montaggio: Identify a suitable gable vent opening. The fan housing is 15 inches in diameter.
Broan Ventilation Calculator

Image 3.1: Ventilation Calculation Guide. This image provides a step-by-step guide to calculate the recommended CFM and minimum soffit vent area for effective ventilation.

3.2. Montaggio della ventola

The fan is typically mounted to a wooden frame constructed around the gable vent opening. This frame provides a secure and stable base for the fan.

  1. Prepare the Mounting Board: Cut a piece of plywood (e.g., 21 inches square) to fit securely within the gable vent framing. Trace the fan's duct shape onto the plywood and cut out the opening.
  2. Pre-wire the Fan: Before mounting, connect 14/2 electrical wire to the fan's junction box. This makes wiring easier than doing it in a confined attic space.
  3. Secure the Fan to the Board: Center the fan on the prepared plywood board. Use 1/2-inch wood screws for the inner mounting holes and 1 1/2-inch wood screws for the outermost holes, ensuring they penetrate into the studs of the frame.
  4. Install the Assembly: Position the fan and plywood assembly into the gable vent opening. Secure it to the existing attic framing (e.g., 2x4s) using screws. Start with a few screws to support the unit, then add more to ensure it is very secure.
  5. Run Electrical Wiring: Route the electrical wire from the fan along the attic ridge to your power source (e.g., an existing outlet converted to a switch). Secure the wire with tacks every few feet.
  6. Connettiti all'alimentazione: Wire the fan to a dedicated switch or power source according to local electrical codes.
Broan 353 Attic Ventilator Installation

Image 3.2: Gable Mount Fan Installation. This image illustrates the Broan 353 fan mounted within a wooden frame in a gable vent opening, showing the electrical connection box.

Broan 353 Fan Dimensions

Image 3.3: Fan Blade and Housing Dimensions. This image provides a visual reference for the fan's dimensions, including the 16-inch overall diameter and 14-inch blade.

4. Istruzioni per l'uso

The Broan-NuTone 353 fan operates automatically via its built-in adjustable thermostat.

  1. Accensione: Ensure the fan is connected to a permanent power source and the wall switch (if installed) is in the "ON" position.
  2. Regolazione del termostato: The thermostat is located within the fan shroud. It controls when the fan activates based on the attic or garage temperature.
    • To adjust the temperature setting, access the thermostat and rotate the dial to your desired activation temperature.
    • Consider that the thermostat inside the shroud may register a slightly lower temperature than the overall attic temperature due to its proximity to the gable vent and airflow. You may need to set it lower than your desired attic temperature to achieve optimal operation.
    • Common settings range from 90°F to 110°F (32°C to 43°C).
  3. Funzionamento automatico: Once set, the fan will automatically turn on when the temperature at the thermostat reaches the set point and turn off when the temperature drops below it.

5. Manutenzione

Regular maintenance helps ensure the longevity and efficient operation of your ventilation fan.

  • Ispezione annuale: Annually, or more frequently in dusty environments, inspect the fan blades and motor for dust and debris buildup.
  • Pulizia: Disconnect power to the fan at the circuit breaker before cleaning. Use a soft cloth or brush to gently remove any accumulated dust or dirt from the blades and motor housing. Do not use water or liquid cleaners directly on electrical components.
  • Controllare eventuali ostruzioni: Ensure the gable vent opening and fan blades are free from obstructions such as bird nests, leaves, or other debris.
  • Lubrificazione del motore: The fan motor is typically permanently lubricated and does not require additional oiling. Refer to the motor's specific instructions if available.

6. Risoluzione Dei Problemi

If your Broan-NuTone 353 fan is not operating as expected, refer to the following common issues and solutions:

ProblemaPossibile causaSoluzione
La ventola non si accende.
  • Nessuna alimentazione all'unità.
  • Thermostat set too high or faulty.
  • Guasto al motore.
  • Power junction box failure.
  • Controllare l'interruttore automatico e l'interruttore a parete.
  • Adjust thermostat to a lower temperature. If still not working, thermostat may need replacement.
  • If motor does not spin freely by hand or does not start when power is directly applied (bypassing thermostat), the motor may need replacement.
  • Inspect wiring and junction box for loose connections or damage.
Fan is excessively noisy or vibrates.
  • Montaggio allentato.
  • Detriti sulle pale del ventilatore.
  • Cuscinetti del motore usurati.
  • Lack of vibration isolation.
  • Assicurarsi che tutte le viti di montaggio siano ben serrate.
  • Scollegare l'alimentazione e pulire le pale della ventola.
  • If noise persists, motor may need replacement.
  • Consider adding rubber spacers or isolation pads between the fan's mounting ears and the wall to reduce transmitted noise.
La ventola funziona costantemente.
  • Termostato impostato su una temperatura troppo bassa o difettoso.
  • Ambient temperature consistently above thermostat setting.
  • Adjust thermostat to a higher temperature.
  • Ensure the attic/garage temperature is actually dropping below the set point. If not, the fan is operating as intended.

7. Specifiche

CaratteristicaDettaglio
MarcaBroan-NuTone
Nome del modello353
Tipo di montaggioGable Mount
Capacità del flusso d'aria760 CFM (piedi cubi al minuto)
Voltage120 Volt
Cosatage60 watt
Velocità1030 giri al minuto
Livello di rumore14.4 decibel
Dimensioni del prodotto (P x L x A)15"P x 1"L x 8"A (alloggiamento)
Diametro lama14 pollici
MaterialeGalvanized Steel (Housing), Metal (Blade)
Caratteristica specialeAdjustable Built-in Thermostat
Fonte di alimentazioneAC
Peso dell'articolo11.1 libbre
Codice UPC026715001538

8. Garanzia e supporto

For warranty information, technical support, or to purchase replacement parts, please contact Broan-NuTone customer service or visit their official websito. Conservare la ricevuta d'acquisto come prova d'acquisto per eventuali reclami in garanzia.

Broan-NuTone Ufficiale Websito: www.broan-nutone.com

© 2024 Broan-NuTone. Tutti i diritti riservati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.