Lithonia Lighting OFTH 300PR 120 P WH-M12

Lithonia Lighting OFTH Twin PAR Holder Adjustable Dusk-to-Dawn Outdoor Flood Light Instruction Manual

1. Introduzione

The Lithonia Lighting OFTH Twin PAR Holder is a durable and reliable outdoor lighting solution designed for residential and light commercial use. It provides focused illumination for areas such as driveways, patios, and other exterior spaces, enhancing both safety and security. This fixture features a built-in dusk-to-dawn photocell sensor for automatic operation and tool-free adjustable heads for precise light direction.

2. Informazioni sulla sicurezza

AVVERTIMENTO: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installation or servicing. All electrical connections must be in accordance with local codes, ordinances, or the National Electric Code (NEC). Consult a qualified electrician if you are unfamiliar with proper electrical wiring connections.

  • Garantire la fornitura voltage is correct (120 Volts).
  • Collegare l'apparecchiatura a cavi di alimentazione classificati per almeno 75°C (167°F).
  • Non installare vicino a materiali combustibili.
  • Use only outdoor-rated PAR medium base flood light bulbs up to 150W (not included).
  • Fixture is CUL listed for US and Canadian safety standards and suitable for wet locations.

3. Configurazione (installazione)

This outdoor lighting fixture is designed for easy mounting to a junction box and is suitable for eave or wall-mount only. Make sure power is turned off before proceeding with installation.

Fasi di installazione:

  1. Install the Cross Bar to the Junction Box using the two provided screws.
  2. Position the Gasket on the back of the Mounting Plate, routing wires through the center of the Gasket.
  3. To ground the fixture, connect the house supply ground wire and the fixture ground (green & yellow wire) to the Green Ground Screw on the Cross Bar. (Note: If house wiring does not include a ground wire, consult your local electrical code for approved grounding methods.)
  4. Use Wirenuts to connect the black fixture wire to the black house power supply wire and the white fixture wire to the white (neutral) house supply wire. (Note: For proper connection, place Wirenut over wires and twist clockwise until tight.)
  5. Remove the Nut from the center of the Cross Bar. Align the Nipple with the hole in the center of the Mounting Plate and secure with the Nut.
  6. Install two (2) PAR Lamps (not included) and adjust the lampholders to illuminate the desired area. (Note: Position lampholders below horizontal to avoid water getting into the lampholders.)
  7. Turn on electricity at the fuse or circuit breaker box and verify successful installation.
Diagram showing 6 steps for installing the Lithonia Lighting Twin PAR Holder
Figure 1: Installation Guide for the OFTH Twin PAR Holder. This diagram illustrates the 6 simple steps for installing the fixture, including attaching the cross bar, positioning the gasket, wiring connections, securing the mounting plate, and installing lamps.
Video 1: Lithonia Lighting OFTH Twin PAR Holder Installation Overview. This video provides a visual guide to the installation process, demonstrating each step from mounting the cross bar to connecting the wiring and installing the lamps.
Lithonia Lighting OFTH Twin PAR Holder installed on a white soffit
Figure 2: The OFTH Twin PAR Holder installed on a white soffit, demonstrating its discreet profile and how the adjustable heads can be positioned to direct light.

4. Istruzioni per l'uso

The OFTH Twin PAR Holder features a built-in dusk-to-dawn photocell sensor. This sensor automatically turns the lights on at dusk when ambient light levels fall below a certain threshold and turns them off at dawn when sufficient natural light is detected. This provides hands-free convenience and helps conserve energy.

  • Funzionamento automatico: Once installed and powered, the photocell will manage the light's on/off cycles based on natural light.
  • Teste regolabili: The tool-free adjustable heads allow for up/down and side-to-side aiming, enabling you to direct light precisely where needed for optimal illumination and security.
Close-up of the dusk-to-dawn photocell sensor on the Lithonia Lighting flood light
Figura 3: Un primo piano view of the dusk-to-dawn photocell sensor, which automatically controls the light fixture based on ambient light conditions.
Video 2: Lithonia Lighting OFTH Twin PAR Holder OverviewQuesto video fornisce una panoramica generaleview of the product's features, including its adjustable heads and dusk-to-dawn functionality, showcasing its application in outdoor settings.

5. Manutenzione

Regular maintenance ensures optimal performance and longevity of your flood light fixture.

  • Pulizia: Pulire periodicamente l'apparecchio con un panno morbido eamp panno per rimuovere sporco e detriti. Non utilizzare detergenti abrasivi o solventi.
  • Sostituzione della lampadina: Ensure power is off before replacing bulbs. Use only outdoor-rated PAR medium base flood light bulbs up to 150W.
  • Ispezione: Annually inspect the fixture for any signs of wear, damage, or loose connections. Address any issues promptly.
Lithonia Lighting flood light installed on a brick wall during rain, highlighting its weather-resistant design
Figure 4: The flood light fixture is shown installed on a brick wall during a rain shower, illustrating its weather and rust-resistant die-cast aluminum construction, designed to withstand outdoor elements.

6. Risoluzione Dei Problemi

If your flood light is not functioning as expected, refer to the following common issues and solutions:

ProblemaPossibile causaSoluzione
La luce non si accende al tramonto.Power is off; faulty bulb; photocell obstructed or faulty.Check circuit breaker; replace bulb; ensure photocell is clear of obstructions or replace fixture if faulty.
La luce rimane accesa durante il giorno.Photocell obstructed by light source; faulty photocell.Relocate fixture or remove light obstruction; replace fixture if photocell is faulty.
La luce lampeggia o si accende e si spegne rapidamente.Loose wiring; faulty bulb; intermittent power supply.Check all wiring connections; replace bulb; consult an electrician for power supply issues.

7. Specifiche

CaratteristicaDettaglio
MarcaIlluminazione Lithonia
Numero di modelloOFTH 300PR 120 P WH-M12
ColoreBianco
MaterialeAlluminio, vetro
StileFotocellula dal tramonto all'alba
Voltage120 Volt
Cosatage (massimo)150 watts per lamp (total 300W)
Numero di sorgenti luminose2
Base della lampadinaE26 Medio
Uso interno/esternoAll'aperto
Tipo di montaggioWall Mount, Semi Flush Mount
Livello di resistenza all'acquaResistente all'acqua
Dimensioni (L x P x A)4.75 cm L x 4.75 cm P x 3.5 cm A
Peso dell'articolo1 libbre
CertificazioneElenco cUL

8. Informazioni sulla garanzia

This Lithonia Lighting product comes with a one-year limited manufacturer's warranty. Please retain your proof of purchase for any warranty claims.

9. Supporto

For further assistance, technical support, or to inquire about replacement parts, please visit the official Lithonia Lighting websito o contattare il servizio clienti. Puoi anche visitare il sito Lithonia Lighting Store on Amazon per ulteriori informazioni sul prodotto.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.