Intel AXX750WPS

Intel AXX750WPS 750W Hot-Plug Redundant Power Supply User Manual

Model: AXX750WPS

1. Introduzione

This manual provides essential information for the safe and efficient use of your Intel AXX750WPS 750W Hot-Plug Redundant Power Supply. This power supply module is designed for use in compatible server systems, offering reliable power delivery and redundancy for critical applications. Please read this manual thoroughly before installation and operation.

2. Informazioni sulla sicurezza

Per evitare lesioni e danni all'apparecchiatura, osservare sempre le seguenti precauzioni di sicurezza:

  • Rischio elettrico: Questo prodotto funziona con un volume elevatotage. L'installazione e la manutenzione devono essere eseguite solo da personale qualificato.
  • Messa a terra: Ensure the server chassis is properly grounded before installing or removing the power supply.
  • Hot-Plug Safety: While designed for hot-plugging, always follow the server manufacturer's guidelines for hot-swapping components to avoid system disruption.
  • Ventilazione: Do not block ventilation openings on the power supply or server. Adequate airflow is crucial for proper cooling.
  • Umidità: Keep the power supply away from liquids and excessive humidity.
  • Scarica statica: Use anti-static precautions (e.g., wrist strap) when handling the power supply to prevent damage from electrostatic discharge.

3. Contenuto della confezione

Verifica che il pacco contenga i seguenti articoli:

  • Intel AXX750WPS 750W Hot-Plug Redundant Power Supply Module
  • Documentazione (questo manuale o guida rapida)

4. Prodotto finitoview

The Intel AXX750WPS is a 750-watt hot-plug power supply module designed for server environments requiring high availability and efficient power delivery. Its key features include:

  • Potenza in uscita 750 Watt: Fornisce ample power for demanding server configurations.
  • Capacità Hot-Plug: Allows for replacement or installation without powering down the server, minimizing downtime.
  • Redundant Design: Supports N+1 or N+N redundancy configurations when used with multiple identical power supplies in a compatible server chassis.
  • Correzione del fattore di potenza (PFC): Improves power efficiency and reduces energy waste.
  • Raffreddamento ad aria: Integrated fan for effective heat dissipation.
Davanti view of the Intel AXX750WPS power supply module

Figura 4.1: Davanti view of the Intel AXX750WPS power supply module, showing the handle and connector interface.

5. Configurazione e installazione

Before proceeding with installation, ensure your server system is compatible with the Intel AXX750WPS power supply module and has an available power supply bay.

5.1 Controlli pre-installazione

  1. Verify that the server is powered off or in a state that supports hot-swapping, as per the server manufacturer's instructions.
  2. Ensure you have an anti-static wrist strap connected to a grounded surface.
  3. Confirm that the power supply bay is clear of obstructions.

5.2 Passaggi di installazione

  1. Carefully unpack the new Intel AXX750WPS power supply module.
  2. If replacing an existing power supply, unlatch and pull the handle to slide the old module out of the bay.
  3. Align the new power supply module with the empty bay in the server chassis.
  4. Gently slide the module into the bay until it is fully seated and the latch mechanism engages. You should feel a click or resistance indicating it's properly connected.
  5. Connect the AC power cord to the power supply module and then to a grounded power outlet or PDU.
  6. Observe the status indicator lights on the power supply (refer to Section 6.2 for details).
Illustration of inserting a hot-plug power supply into a server bay

Figura 5.1: Proper insertion of the Intel AXX750WPS power supply module into a compatible server bay.

6. Istruzioni per l'uso

6.1 Accensione/Spegnimento

Once the power supply is installed and connected to an AC source, it will typically power on automatically if the server is already running or when the server is powered on. For redundant configurations, individual power supplies can be removed and inserted while the system is operational.

6.2 Indicatori di stato

The Intel AXX750WPS typically features LED indicators to communicate its operational status. Common indicators include:

  • Green/Amber LED: A solid green light usually indicates normal operation and power output. An amber or flashing light may indicate a fault or a non-redundant state.
  • Refer to your server's documentation for specific interpretations of power supply LED patterns, as these can vary by system.

6.3 Redundancy Operation

In a redundant configuration (e.g., two AXX750WPS modules in a server designed for N+1 redundancy), if one power supply fails, the other(s) will automatically take over the full load, ensuring continuous operation. The failed module can then be hot-swapped for a new one without interrupting server uptime.

7. Manutenzione

The Intel AXX750WPS power supply is designed for minimal maintenance. However, periodic checks can help ensure optimal performance and longevity.

  • Rimozione della polvere: Periodically inspect the power supply and server ventilation areas for dust accumulation. Use compressed air to gently clear dust from vents and fan grilles. Ensure the server is powered down and unplugged if removing the power supply for cleaning.
  • Ispezione dei cavi: Check AC power cords for any signs of damage, fraying, or loose connections. Replace damaged cables immediately.
  • Condizioni ambientali: Ensure the server environment maintains appropriate temperature and humidity levels as specified by the server manufacturer.

8. Risoluzione Dei Problemi

If you encounter issues with your Intel AXX750WPS power supply, consider the following troubleshooting steps:

ProblemaPossibile causaSoluzione
Power supply LED is off.No AC power, module not fully seated, or power supply failure.
  • Check AC power cord connection to the power supply and outlet.
  • Ensure the power supply module is fully seated in its bay.
  • Provare la presa di corrente con un altro dispositivo.
  • If in a redundant configuration, check if the other power supply is operational.
Power supply LED is amber/flashing.Fault detected, over-temperature, or non-redundant operation.
  • Consult your server's documentation for specific LED error codes.
  • Assicurare una ventilazione e una temperatura ambiente adeguate.
  • If in a redundant setup, verify the status of other power supplies.
  • Consider replacing the module if the fault persists.
Il server non si accende.Power supply issue, server component failure, or insufficient power.
  • Verify all power supplies are installed correctly and showing normal status.
  • Garantire l'acqua totaletage is sufficient for all installed server components.
  • Refer to your server's diagnostic procedures.

For advanced troubleshooting or issues not resolved by these steps, contact Intel support or your server vendor.

9. Specifiche

CaratteristicaDettaglio
Nome del modelloAXX750WPS
MarcaIntel
Uscita Wattage750 Watt
Fattore di formaHot-plug / Redundant (plug-in module)
Correzione del fattore di potenza (PFC)
Metodo di raffreddamentoAria
Dispositivi compatibiliPersonal Computer (Server systems)
Dimensioni articolo (L x P x A)19.5 x 9.5 x 5 pollici
Peso dell'articolo4.7 libbre
Codice UPC735858207294, 675900998322, 735858206501

10. Garanzia e supporto

This Intel AXX750WPS power supply module is covered by Intel's standard product warranty. For detailed warranty terms and conditions, please refer to the official Intel website or the warranty documentation included with your original server system purchase.

For technical support, product information, or service requests, please visit the official Intel support website or contact your authorized Intel reseller or server manufacturer.

© 2026 Intel Corporation. Tutti i diritti riservati. Intel e il logo Intel sono marchi registrati di Intel Corporation o delle sue consociate negli Stati Uniti e/o in altri Paesi.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.