Eltako S2U12DDX-UC

Eltako S2U12DDX-UC Programmable Clock User Manual

Model: S2U12DDX-UC | Brand: Eltako

1. Informazioni sulla sicurezza

AVVERTIMENTO: Electrotechnical work must be performed exclusively by specialized electricians or under their direct supervision and guidance. Improper installation or handling can lead to serious injury or damage.

Always disconnect power before installation, maintenance, or any work on the device. Ensure all local and national electrical codes are followed.

2. Prodotto finitoview

The Eltako S2U12DDX-UC is a 2-channel programmable clock designed for DIN rail mounting. It features two potential-free contacts (1+1) rated at 16 A/250 V AC. This device supports LED lamps up to 600 W and incandescent bulbs up to 2000 W. It includes an Astro function for automatic switching based on sunrise/sunset, an illuminated display, and a power reserve of approximately 7 days without battery.

Thanks to patented Eltako-Duplex (DX) technology, the normally potential-free contacts can switch 230 V AC 50 Hz, significantly reducing wear. This is achieved by connecting the N conductor to terminal (N) and L to 1 (L) and/or 3 (L), resulting in an additional standby loss of only 0.1 W. The use of bistable relays eliminates coil power loss and heating when switched on.

Up to 60 memory locations are freely assignable across the channels. The device includes automatic date and summer/winter time changes.

Caratteristiche principali:

  • Installazione: Montaggio su guida DIN
  • Numero di canali: 2
  • Volume di fornituratage: 8-230 V CA/CC
  • Riserva di carica: Circa 480 ore (7 giorni)
  • Contatti: 1+1 potential-free contacts, 16 A/250 V AC
  • Capacità di carico: 230V LED lamps up to 600 W, incandescent bulbs up to 2000 W
  • Funzioni: Astro function, date, automatic summer/winter time change, centralized control, random mode
  • Memoria: Up to 60 freely assignable memory locations
  • Display: Schermo illuminato
Eltako S2U12DDX-UC Programmable Clock mounted on a DIN rail

Figura 1: Eltako S2U12DDX-UC Programmable Clock. This image shows the compact design of the device, suitable for DIN rail installation, with its display and control buttons visible on the front panel.

3. Impostazione

3.1. Installazione

The Eltako S2U12DDX-UC is designed for DIN EN 60715 TH35 support rail mounting. It occupies 1 division unit (18 mm wide, 58 mm deep).

  1. Prima dell'installazione, assicurarsi che l'alimentazione sia scollegata dall'interruttore principale.
  2. Mount the device onto a standard DIN rail.
  3. Connect the N conductor to the (N) terminal.
  4. Connect the L conductor to 1 (L) and/or 3 (L) for the respective channels.
  5. For centralized control, connect the control input (+A1) for central ON or OFF with priority. The supply and control voltage for central control is 8 to 230 V UC.
  6. Prima di ripristinare l'alimentazione, verificare che tutti i collegamenti siano sicuri e corretti.

3.2. Initial Configuration - Language Setting

After applying power for the first time, the language selection menu will appear.

  1. Within 10 seconds of applying power, use the IMPOSTATO button to select the desired language (D=German, GB=English, F=French, IT=Italian, ES=Spanish).
  2. Conferma la tua selezione con il MODALITÀ pulsante.
  3. The display will then show the normal view: weekday, time, day, and month.

Note on Speed: Parameters increase rapidly when the IMPOSTATO button is pressed and held. Release and press again for longer to change direction.

4. Istruzioni per l'uso

4.1. Impostazione dell'ora

  1. Premere MODALITÀ.
  2. In the PRG (program) menu, use IMPOSTATO to find the UHR (time) function.
  3. Select UHR with MODALITÀ.
  4. For 'S' (hours), use IMPOSTATO to adjust the hour and confirm with MODALITÀ.
  5. Proceed similarly for 'M' (minutes).

4.2. Impostazione della data

  1. Premere MODALITÀ.
  2. Utilizzo IMPOSTATO to find the DAT (date) function.
  3. Select DAT with MODALITÀ.
  4. For 'J' (year), use IMPOSTATO to choose the year and confirm with MODALITÀ.
  5. Proceed similarly for 'M' (month) and 'T' (day).
  6. Finally, 'MO' (weekday) will flash. Adjust with IMPOSTATO e confermare con MODALITÀ.

4.3. Setting the Location (for Astro Function)

A list of German cities can be found in the full user manual for location settings.

  1. Premere MODALITÀ.
  2. Utilizzo IMPOSTATO to find the POS (position) function.
  3. Select POS with MODALITÀ.
  4. For 'BRT' (latitude), use IMPOSTATO to choose the latitude and confirm with MODALITÀ.
  5. Similarly, select longitude for 'LAE' and confirm with MODALITÀ.
  6. Now, for 'GMT', select the time zone and confirm with MODALITÀ.
  7. Optionally, for both channels, a time shift of up to ±2 hours can be entered for WSW (winter solstice) and SSW (summer solstice).

4.4. Manual ON or OFF Switching with Priority

  1. Premere MODALITÀ.
  2. In the PRG menu, use IMPOSTATO to find the INT (interrupt) function.
  3. Select INT with MODALITÀ.
  4. For 'KNL' (channel), use IMPOSTATO to select channel 1 or 2 and confirm with MODALITÀ.
  5. You can now switch between AUT (automatic), ON, or OFF.
  6. After confirming with MODALITÀ, the selected channel's switching position will be applied.
  7. To allow the switching state to change automatically when a time program is active, select AUT.
  8. If MODALITÀ is held for more than 2 seconds during any confirmation, the change is saved, and the normal display appears.

4.5. Summer/Winter Time Change

  1. Premere MODALITÀ.
  2. Utilizzo IMPOSTATO to find the SWZ (summer/winter time) function.
  3. Select SWZ with MODALITÀ.
  4. Switch between ON and OFF with IMPOSTATO e confermare con MODALITÀ. If ON is selected, the change occurs automatically.

4.6. Centralized Control ON or OFF with Priority (in Automatic Mode)

  1. Premere MODALITÀ.
  2. Utilizzo IMPOSTATO to find the ZEA (central control) function.
  3. Select ZEA with MODALITÀ.
  4. You can now switch between ZE (central ON) and ZA (central OFF) with IMPOSTATO e confermare con MODALITÀ.

4.7. Activating/Deactivating Random Mode

  1. Premere MODALITÀ.
  2. Utilizzo IMPOSTATO to find the ZUF (random) function.
  3. Select ZUF with MODALITÀ.
  4. Set to ON (ZUF+) or OFF (ZUF) with IMPOSTATO e confermare con MODALITÀ.
  5. When random mode is active, all switching points for all channels are randomly shifted by up to 15 minutes (earlier ON times, later OFF times).

4.8. Entering Timer Programs

Detailed instructions for entering timer programs are provided in the comprehensive user manual. Each memory location can be used with the Astro function (automatic switching after sunrise or sunset), ON/OFF times, or a pulse switching time (triggers a 2-second pulse). The Astro ON/OFF time can be shifted by ±2 hours. Additionally, a time shift of up to ±2 hours can be entered for solstices.

4.9. Activating/Deactivating Key Lock

  1. Attivare: Premere brevemente MODALITÀ E IMPOSTATO simultaneously. Lock with IMPOSTATO for 'LCK'. This is indicated by an arrow next to the lock icon.
  2. Per disattivare: Premere MODALITÀ E IMPOSTATO simultaneously for 2 seconds. Unlock with IMPOSTATO for 'UNL'.

5. Manutenzione

The Eltako S2U12DDX-UC programmable clock is designed for long-term, maintenance-free operation. No specific user maintenance is required. For cleaning, use a dry, soft cloth. Do not use abrasive cleaners or solvents.

6. Risoluzione Dei Problemi

If the device does not function as expected, review the programming steps in Section 4. Ensure all connections are secure and power supply is stable.

  • Display not illuminated: Check power supply. Press MODE or SET to activate backlight.
  • Incorrect switching times: Verify time, date, and location settings. Check individual program entries.
  • La tastiera non risponde: Check if key lock is active (Section 4.9).
  • Malfunzionamento generale: Disconnect power for a few minutes, then reconnect. If issues persist, contact Eltako customer support.

7. Specifiche

Caratteristica Specificazione
Produttore Eltako
Numero di modello S2U12DDX-UC
Colore Blu
Materiale Plastica
Voltage 230 Volt
Volume di fornituratage (Control) 8-230 V UC (AC/DC)
Numero di articoli 1
Batterie incluse NO
Batterie richieste NO
Riserva di carica Approx. 7 days (480 hours)
Disponibilità dei pezzi di ricambio 1 anno
Installazione DIN rail (1 division unit, 18mm wide, 58mm deep)
Numero di canali 2

8. Garanzia e supporto

For warranty information and technical support, please contact Eltako directly or refer to their official website. Details regarding spare parts availability are typically provided for 1 year from the date of purchase.

© 2024 Eltako. Tutti i diritti riservati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.