Danner 40140
Supreme Hydro-Mag 2400 GPH Recirculating Water Pump User Manual
Modello: 40140
Brand: Danner Manufacturing, Inc.

Introduzione
The Danner Supreme Hydro-Mag 2400 GPH Recirculating Water Pump is engineered for efficient water circulation in various applications, including hydroponic systems, ponds, and fountains. This pump utilizes time-proven magnetic drive technology, ensuring energy-efficient and oil-free operation. It is designed for both in-line and submersible use, offering versatility and reliability.

Figura 1: Supreme Hydro-Mag 2400 GPH Water Pump, front view. This image shows the main body of the pump with its threaded outlet connection.
Informazioni sulla sicurezza
- Scollegare sempre l'alimentazione prima di effettuare qualsiasi operazione di manutenzione o installazione.
- Assicurarsi che la pompa sia correttamente collegata a terra per evitare scosse elettriche.
- Do not operate the pump dry. Ensure it is fully submerged or primed for inline use before connecting power.
- Controllare regolarmente il cavo di alimentazione per verificare che non sia danneggiato. Non utilizzare se il cavo è sfilacciato o danneggiato.
- Tenere i bambini e gli animali domestici lontani dalla pompa e dal dispositivo d'acqua durante il funzionamento.
- This pump is designed for water circulation only. Do not use with flammable liquids or chemicals.
Impostare
1. Disimballaggio
Estrarre con cautela la pompa e tutti gli accessori dall'imballaggio. Verificare la presenza di eventuali segni di danneggiamento durante il trasporto. Conservare l'imballaggio per un eventuale stoccaggio o trasporto futuro.
2. Installation Options: Submersible or Inline
The Supreme Hydro-Mag pump can be installed either fully submerged in water or as an inline pump outside the water source.
- Submersible Installation: Place the pump directly into the water at the desired location. Ensure it is stable and not obstructed by debris. The pump must be fully submerged for proper cooling and operation.
- Inline Installation: For inline use, the pump must be placed below the water level of the source to ensure it is gravity-fed and remains primed. Connect appropriate plumbing to the inlet and outlet ports. Ensure all connections are watertight.

Figura 2: Lato view of the Supreme Hydro-Mag pump, showing the inlet and outlet ports. This view helps in understanding plumbing connections for inline setup.
3. Connessioni
- Inlet and Outlet: The pump features a 1" FPT (Female Pipe Thread) inlet and a 1" MPT (Male Pipe Thread) outlet. Connect appropriate tubing or PVC fittings to these ports. Use thread sealant tape for secure, leak-free connections.
- Cavo di alimentazione: The pump is equipped with a 10-foot power cord. Ensure the cord is routed safely and is not pinched or exposed to sharp edges. Connect to a grounded electrical outlet.
4. Venturi Adjustment (Applicable to Models 2-18)
For models that feature an adjustable Venturi, this mechanism allows for aeration of the water flow, which can stimulate root growth in hydroponic applications. Consult your specific model's documentation to determine if this feature is present and how to adjust it for optimal air intake.

Figura 3: Image illustrating healthy hydroponic plant roots submerged in water. Proper aeration, which can be enhanced by the Venturi feature, contributes to such root development.
Istruzioni per l'uso
1. Avvio iniziale
Once the pump is installed and all connections are secure, connect the power cord to a suitable grounded electrical outlet. The pump should begin circulating water immediately. Monitor the flow to ensure it is consistent and free of air bubbles.
2. Flow Rate Considerations
The Supreme Hydro-Mag 2400 GPH pump has a maximum flow rate of 2400 Gallons Per Hour (GPH) and a maximum shut-off head of 17 feet. The actual flow rate will vary depending on the head height (vertical distance the water is lifted) and any restrictions in the plumbing system. Ensure the pump's capacity matches the requirements of your system for efficient nutrient distribution and coverage.

Figura 4: A person holding a hydroponic lettuce plant, demonstrating the type of application this pump supports. Adequate water circulation is crucial for such systems.
3. Continuous Duty Operation
This pump is designed for continuous duty operation, meaning it can run constantly without needing to be turned off periodically. Its robust design and magnetic drive technology contribute to its long-term reliability.
Manutenzione
Una manutenzione regolare garantisce la longevità e le prestazioni ottimali della pompa.
1. Cleaning the Impeller and Housing
Over time, debris and mineral deposits can accumulate around the impeller, reducing pump efficiency. To clean:
- Scollegare la pompa dalla fonte di alimentazione.
- Remove the pump from the water or disconnect plumbing for inline setups.
- Carefully open the pump housing to access the impeller. Refer to the pump's diagram for specific disassembly instructions.
- Clean the impeller and the impeller chamber thoroughly with a soft brush and clean water. Remove any stringy algae, hair, or mineral buildup.
- Reassemble the pump, ensuring all seals are properly seated.

Figura 5: Indietro view of the Supreme Hydro-Mag pump, showing the screws that secure the pump housing. These screws typically need to be removed for impeller access during cleaning.
2. Design senza olio
The Supreme Hydro-Mag pump is designed to be oil-free, eliminating the need for lubrication and preventing potential contamination of your water system. There are no seals to wear out, contributing to its low maintenance requirements.
Risoluzione dei problemi
| Problema | Possibile causa | Soluzione |
|---|---|---|
| La pompa non funziona. | Nessuna alimentazione; girante intasata; motore danneggiato. | Check power connection and circuit breaker. Disconnect power and clean impeller. If motor is damaged, contact customer support. |
| Flusso d'acqua ridotto. | Clogged impeller or intake screen; kinked tubing; excessive head height. | Clean impeller and intake screen. Check and straighten tubing. Ensure pump is suitable for the required head height. |
| La pompa è rumorosa. | Debris in impeller; pump running dry (inline); vibration. | Disconnect power and clean impeller. Ensure pump is fully submerged or properly primed for inline use. Check for stable placement. |
| Pump stops intermittently. | Overheating due to blockage or low water level; electrical issue. | Check for blockages and ensure adequate water level. Verify electrical connections. |
Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Numero di modello | 40140 |
| Portata massima | 2400 GPH (Gallons Per Hour) / 40 GPM (Gallons Per Minute) |
| Maximum Lifting Height (Shut-off) | 17 piedi |
| Consumo energetico | 237 watt / 2.2 Amps |
| Collegamento di ingresso | 1" FPT (Female Pipe Thread) |
| Collegamento alla presa | 1" MPT (Male Pipe Thread) |
| Lunghezza del cavo di alimentazione | 10 piedi |
| Tipo di operazione | Submersible or Inline |
| Materiale | Acrilonitrile Butadiene Stirene (ABS) |
| Dimensioni (L x P x A) | 7.25 x 3.38 x 5.88 pollici |
| Peso dell'articolo | 9.12 libbre |
Garanzia
The Danner Supreme Hydro-Mag 2400 GPH Recirculating Water Pump comes with a Garanzia limitata di 5 anno. This warranty covers defects in materials and workmanship under normal use. Please retain your proof of purchase for warranty claims. For full warranty details and terms, refer to the official Danner Manufacturing, Inc. websito o contattare il loro servizio clienti.
Supporto
For further assistance, technical support, or to inquire about replacement parts, please contact Danner Manufacturing, Inc. customer service or visit their official websito:
- Danner Manufacturing, Inc. Official Websito: www.danner.com
- Danner Store on Amazon: Visit the Danner Store
È inoltre possibile trovare risorse aggiuntive e FAQ nelle pagine di supporto.
Ask a question about this manual
Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.