Rigol DS1054Z
Rigol DS1054Z Digital Oscilloscope User Manual
Modello: DS1054Z
Introduzione
Welcome to the user manual for the Rigol DS1054Z Digital Oscilloscope. This document provides essential information for the safe and effective use of your new instrument. The DS1054Z is a versatile 4-channel, 50 MHz digital oscilloscope designed for precise waveform analysis and measurement in various electronic applications.
Informazioni sulla sicurezza
Please read all safety instructions carefully before operating the device to prevent injury or damage to the instrument.
- Fonte di energia: Assicurarsi che l'oscilloscopio sia collegato a una fonte di alimentazione con la tensione correttatage and frequency as specified on the device.
- Messa a terra: Always use a properly grounded power cord to prevent electric shock.
- Ventilazione: Non ostruire le aperture di ventilazione. Garantire un adeguato flusso d'aria attorno allo strumento per evitare il surriscaldamento.
- Ambiente: Operate the oscilloscope in a dry, clean environment, away from direct sunlight, high temperatures, humidity, and strong electromagnetic fields.
- Esposizione al liquido: Avoid exposing the instrument to liquids. If liquid enters the device, disconnect power immediately and have it inspected by qualified service personnel.
- Manutenzione: Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato. Non tentare di aprire o riparare lo strumento da soli.
Contenuto della confezione
Verifica che tutti gli articoli elencati di seguito siano inclusi nel tuo pacchetto:
- Rigol DS1054Z Digital Oscilloscope
- 4 x Passive Probes (RP2200)
- Cavo di alimentazione
- Cavo USB
- Certificato di calibrazione
- Quick Guide (Printed)

Image: Rigol DS1054Z Oscilloscope with its standard accessories, including four probes, power cord, and documentation.
Prodotto finitoview
Pannello frontale

Immagine: Frontale view of the Rigol DS1054Z, showing the large display, channel inputs, and control buttons.
The front panel features a large 7-inch WVGA (800x480) TFT display for clear waveform visualization. Key controls include:
- Channel Inputs (CH1-CH4): Connettori BNC per il collegamento delle sonde.
- Controlli verticali: Manopole e pulsanti per regolare la scala verticale (Volt/Div) e la posizione di ciascun canale.
- Controlli orizzontali: Knobs for adjusting horizontal scale (Sec/Div) and position.
- Controlli del grilletto: Buttons and knobs for setting trigger level, mode, and source.
- Pulsanti funzione: Dedicated buttons for Measure, Acquire, Storage, Cursor, Display, Utility, Help, and Menu navigation.
- Porta host USB: Located on the front for connecting USB storage devices.
Pannello posteriore

Immagine: Posteriore view of the Rigol DS1054Z, showing power input, LAN, USB, and auxiliary ports. The serial number DS1ZA233608157 is visible.
Il pannello posteriore offre opzioni di connettività essenziali:
- Potenza in ingresso: Per collegare il cavo di alimentazione CA.
- Porta LAN: Per la connettività di rete e il controllo remoto.
- Porta dispositivo USB: Per la connessione a un computer.
- Aux (TrigOut / PassFail) Port: An auxiliary output for trigger signals or Pass/Fail testing.
Impostare
Collegamento di potenza
- Ensure the oscilloscope is turned off.
- Connect the provided power cord to the power input on the rear panel of the oscilloscope.
- Collegare l'altra estremità del cavo di alimentazione a una presa di corrente CA dotata di messa a terra.
Probe Connection and Compensation
- Connect the probe to one of the BNC input channels (CH1-CH4) on the front panel.
- Attach the probe clip to the probe compensation test point (usually a square wave output) on the front panel.
- Accendere l'oscilloscopio.
- Adjust the probe compensation using a small screwdriver on the probe body until a flat-top square wave is displayed on the screen. This ensures accurate measurements.

Image: The Rigol DS1054Z in an operational setup, demonstrating probe connection and signal acquisition.
Istruzioni per l'uso
Misure di base
The DS1054Z offers a wide range of measurement capabilities:
- Selezione canale: Use the CH1-CH4 buttons to enable or disable channels.
- Scala verticale: Adjust the Volts/Div knob to change the vertical sensitivity.
- Scala orizzontale: Adjust the Sec/Div knob to change the time base.
- Configurazione automatica: Premere il tasto AUTO button for automatic setup of vertical, horizontal, and trigger systems.
- Measure Function: Premere il tasto Misura button to display automatic measurements such as frequency, period, peak-to-peak voltage, e altro ancora.
- Funzioni matematiche: Utilizzare il MATEMATICA button for waveform operations like addition, subtraction, multiplication, division, FFT, and integration.

Multiple waveform display.

Single pulse waveform analysis.

Rising and falling edge signals.

Decoded serial data display.

Amplitude modulated waveform.

Complex multi-channel signal.

Lissajous figures for phase analysis.
Innesco
Triggering is crucial for stable waveform display. Use the trigger controls to set the trigger type (Edge, Pulse, Slope, Video, etc.), source (CH1-CH4, AC Line, External), and level. The DS1054Z supports advanced triggering options to capture specific events.
Waveform Display and Analysis
The UltraVision technology provides a deeper memory (12 Mpts, upgradable to 24 Mpts) and a high waveform capture rate (up to 30,000 wfms/s), allowing for the capture of transient events and detailed signal analysis. The multi-level intensity grading display helps visualize signal variations over time.
Manutenzione
- Pulizia: Utilizzare un panno morbido e asciutto per pulire l'esterno dell'oscilloscopio. Per lo sporco ostinato, utilizzare un panno leggermenteamp cloth with mild detergent can be used. Do not use abrasive cleaners or solvents.
- Magazzinaggio: Store the oscilloscope in a cool, dry place, away from direct sunlight and extreme temperatures. When not in use for extended periods, disconnect the power cord.
- Calibrazione: For optimal performance, periodic calibration by qualified service personnel is recommended.
Risoluzione dei problemi
If you encounter issues with your Rigol DS1054Z, refer to the table below for common problems and solutions.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Nessun display dopo l'accensione | Power cord not connected; Power switch off; Fuse blown. | Check power cord connection; Ensure power switch is on; Contact service for fuse replacement. |
| Nessuna forma d'onda visualizzata | Probe not connected; Channel disabled; Vertical scale too high/low; Trigger not set correctly. | Connect probe; Enable channel; Adjust Volts/Div; Adjust trigger level/mode. |
| Forma d'onda instabile | Incorrect trigger settings; Probe compensation incorrect. | Adjust trigger level/mode/source; Perform probe compensation. |
| Rumore eccessivo della ventola | Funzionamento normale; accumulo di polvere. | Ensure proper ventilation; Clean dust from vents (if accessible and safe). If persistent or unusual, contact support. |
Specifiche
Key technical specifications for the Rigol DS1054Z Digital Oscilloscope:
| Caratteristica | Specificazione |
|---|---|
| Larghezza di banda | 50 MHz |
| Canali | 4 |
| S in tempo realeampla tariffa | 1 GSa/s (single channel) |
| Profondità della memoria | 12 Mpts (upgradable to 24 Mpts) |
| Velocità di acquisizione della forma d'onda | Fino a 30,000 wfms/s |
| Display | 7-inch WVGA (800x480) TFT |
| Connettività | USB Host, USB Device, LAN, Aux (TrigOut / PassFail) |
| Dimensioni (L x P x A) | 13 x 7 x 5 pollici |
| Peso | 6.6 libbre |
| Numero di modello | DS1054Z |
Informazioni sulla garanzia
The Rigol DS1054Z Digital Oscilloscope comes with a 3 ANNO warranty. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, refer to the documentation provided with your product or visit the official Rigol websito.
Supporto
For technical support, product inquiries, or service requests, please contact Rigol customer support through their official channels. You can find more information and resources on the Rigol Official Store on Amazon o la loro azienda websito.