Introduzione
This manual provides detailed instructions for the setup, operation, and maintenance of your TONOR XLR Condenser Microphone Kit TN516BL. Please read this manual thoroughly before using the product to ensure proper functionality and longevity.

Image: The TONOR XLR Condenser Microphone Kit, featuring the microphone, pop filter, and adjustable arm stand.
Contenuto della confezione
The TONOR XLR Condenser Microphone Kit TN516BL includes the following components:
- Microfono a condensatore
- Adjustable Scissor Arm Stand
- Montaggio su scrivania Clamp
- Supporto antiurto
- Filtro pop
- Parabrezza in schiuma
- Cavo da XLR a XLR
- 3.5mm to XLR Cable
- Adattatore audio USB
Istruzioni di installazione
Follow these steps to assemble and set up your microphone kit:
- Fix the Desk Mount Clamp: Securely attach the desk mount clamp to the edge of a desk or table.
- Insert Arm Stand: Inserire la base del piede (nera) del supporto con braccio regolabile nel supporto da tavolo clamp.
- Stringere la vite: Serrare la vite sul clamp to firmly hold the arm stand in place.
- Screw Shock Mount: Avvitare il supporto antiurto sull'estremità filettata del supporto del braccio regolabile.
- Inserisci microfono: Carefully insert the condenser microphone into the shock mount.
- Fix Pop Filter: Attach the pop filter to the adjustable arm stand to complete the assembly.

Image: A visual guide demonstrating the six steps for assembling the microphone kit, from attaching the desk clamp to fixing the pop filter.
Opzioni di connessione
The TONOR XLR Condenser Microphone Kit offers two primary connection methods:
Way 1: Connecting to a Laptop or Desktop with USB Audio Adapter
This method is suitable for computers without dedicated XLR inputs or when using a 3.5mm jack for audio input.
- Connect the microphone to a phantom power supply (not included) using an XLR to XLR cable.
- Connect the phantom power supply to the USB audio adapter using an audio input line (3.5mm to XLR or XLR to XLR).
- Plug the USB audio adapter into your laptop or desktop computer.

Image: Diagram illustrating connection method 1, showing the microphone, phantom power, USB sound card, and computer connections.
Way 2: Connecting to a Professional Sound Card or Audio Mixer
This method is recommended for optimal audio quality and control, utilizing a professional sound card or audio mixer with phantom power capabilities.
- Connect the microphone directly to a professional sound card or audio mixer using an audio input cable (XLR to XLR).
- Ensure the sound card or audio mixer provides 48V phantom power to the microphone.
- Connect the sound card or audio mixer to your computer using a USB power cable and audio output cable.

Image: Diagram illustrating connection method 2, showing the microphone connected to a professional sound card or audio mixer, and then to a computer.
Nota importante:
This condenser microphone requires 48V phantom power to operate correctly. If your device (computer, sound card, or mixer) does not provide phantom power, an external phantom power supply (not included) is necessary.
Istruzioni per l'uso
Once the microphone kit is assembled and connected, follow these guidelines for optimal performance:
- Posizionamento del microfono: Position the microphone approximately 6-12 inches (15-30 cm) from the sound source. The cardioid pickup pattern is most sensitive to sounds directly in front of the microphone.
- Utilizzo del filtro anti-pop: Ensure the pop filter is positioned between your mouth and the microphone. This helps to reduce plosive sounds (like 'p' and 'b') and protects the microphone from moisture.
- Regolazione del guadagno: Adjust the input gain on your sound card, audio mixer, or computer settings to achieve an appropriate recording level. Avoid setting the gain too high, which can lead to distortion, or too low, which can result in a weak signal.
- Monitoraggio: Use headphones connected to your audio interface or computer to monitor your sound in real-time and make necessary adjustments.
- Impostazioni software: Configure your recording software or communication application to select the TONOR microphone as the input device.

Image: A person using the TONOR XLR Condenser Microphone Kit in a professional studio environment, demonstrating typical usage.

Image: A person singing into the TONOR XLR Condenser Microphone Kit, highlighting its use for vocal recording.
Prodotto finitoview Video
Video: An official TONOR video providing an overview of the Professional Studio Condenser Microphone Computer PC Microphone Kit, including its components and features.
Manutenzione
Proper maintenance ensures the longevity and performance of your microphone kit:
- Pulizia: Use a soft, dry cloth to clean the microphone body and stand. Do not use liquid cleaners or solvents.
- Magazzinaggio: When not in use, store the microphone in a dry, dust-free environment. It is recommended to use the original packaging or a dedicated microphone case.
- Cura del cavo: Avoid sharp bends or kinks in the cables. Store cables neatly to prevent damage.
- Supporto antiurto: Periodically check the elastic bands of the shock mount for wear and tear. Replace if necessary to maintain effective vibration isolation.
Risoluzione dei problemi
Se riscontri problemi con il tuo kit microfono, fai riferimento ai seguenti problemi comuni e alle relative soluzioni:
- Nessuna uscita audio:
- Ensure 48V phantom power is supplied to the microphone.
- Check all cable connections to ensure they are secure and correctly plugged in.
- Verify that the microphone is selected as the input device in your computer's sound settings and recording software.
- Adjust the input gain/volume levels on your audio interface/mixer and computer.
- Basso volume:
- Confirm 48V phantom power is active.
- Increase the input gain on your audio interface/mixer or computer.
- Ensure the microphone is positioned close enough to the sound source (6-12 inches).
- Suono distorto:
- Reduce the input gain on your audio interface/mixer or computer.
- Ensure the microphone is not too close to the sound source, causing clipping.
- Rumore di fondo eccessivo:
- Ensure the microphone is facing the desired sound source, utilizing its cardioid pattern.
- Riduci al minimo il rumore ambientale nell'ambiente di registrazione.
- Check for ground loops or electrical interference; try connecting to a different power outlet.
Specifiche
| Caratteristica | Specificazione |
|---|---|
| Marca | TONORE |
| Numero di modello | TN516BL |
| Fattore di forma del microfono | Confine |
| Modello polare | Unidirezionale (cardioide) |
| Tecnologia di connettività | USB, XLR |
| Tipo di connettore | 3.5 mm Jack, USB, XLR |
| Fonte di alimentazione | Elettrico con cavo (richiede alimentazione Phantom a 48 V) |
| Sensibilità Audio | 132 decibel |
| Signal-to-Noise Ratio | 76 dB |
| Peso dell'articolo | 8 once (0.5 libbre) |
| Colore | Nero |
| Piattaforma hardware | Portatile, Pc, Tablet |
| Usi consigliati | Streaming, Video Recording, Voice Recording |
Garanzia e supporto
TONOR products typically come with a manufacturer's warranty. Please refer to the warranty card included in your package for specific terms and conditions. For technical support, product inquiries, or warranty claims, please visit the official TONOR websito o contattare direttamente il servizio clienti.
Componenti inclusi: amplifier, USB cable, warranty card.





