This DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank system is designed for residential water setups. It features a 5-gallon hardened steel alloy tank and a stainless steel housing and volute, ensuring durability and compatibility with potable water due to its lead-free fittings and rubber seals. The pump offers a maximum flow of 950 GPH and a total head lift of 115.5 ft., with a maximum well depth of 26 ft. It operates at 120 Volts (AC) and includes thermal protection with automatic reset for enhanced safety and longevity. The maximum water pressure is 50 PSI.

Pompa e serbatoio per pozzi bassi in acciaio inossidabile da 1 HP DRUMMOND

Image: The DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank, featuring a green tank base, a stainless steel pump head, and a green motor housing. A pressure gauge and electrical control box are visible on the pump head.

Informazioni importanti sulla sicurezza

Read and understand all safety warnings and instructions before operating this product. Failure to follow these instructions may result in electric shock, fire, serious injury, or death.

  • Always disconnect power before servicing or performing maintenance on the pump.
  • Garantire un'adeguata messa a terra per evitare scosse elettriche.
  • Non utilizzare la pompa con cavi o spine danneggiati.
  • Tenere i bambini e le persone non autorizzate lontano dalla pompa durante il funzionamento.
  • Installare la pompa in un luogo asciutto e ben ventilato, al riparo dal gelo.
  • Use only for pumping potable water as specified. Do not use for flammable liquids or corrosive chemicals.
  • Ensure all plumbing connections are secure and leak-free before operation.

Istruzioni di installazione

  1. Disimballaggio: Rimuovere con attenzione tutti i componenti dall'imballaggio. Verificare che non vi siano danni dovuti al trasporto.
  2. Posizione: Choose a location that is dry, level, and protected from freezing. Ensure adequate ventilation around the pump.
  3. Montaggio: Secure the pump to a stable surface using appropriate fasteners through the mounting holes on the base.
  4. Collegamenti idraulici:
    • Connect the suction line from the well to the pump's inlet. Ensure the suction line is airtight to prevent air leaks.
    • Connect the discharge line from the pump's outlet to your household plumbing system.
    • Use thread sealant on all threaded connections to prevent leaks.
  5. Adescamento della pompa:
    • Remove the priming plug on the pump housing.
    • Fill the pump housing completely with water until it overflows.
    • Riposizionare saldamente il tappo di adescamento.
  6. Collegamento elettrico: Connect the pump to a dedicated 120V AC grounded electrical outlet. Ensure the circuit is protected by a ground fault circuit interrupter (GFCI). Consult a qualified electrician if unsure.

Istruzioni per l'uso

  1. Avvio iniziale: After completing the setup and priming, turn on the power to the pump. The pump should start and begin to build pressure.
  2. Monitoraggio della pressione: Observe the pressure gauge. The pump is designed to operate within a pressure range, typically turning on at a lower pressure (e.g., 30 PSI) and off at a higher pressure (e.g., 50 PSI).
  3. Aria nel sistema: If the pump runs continuously or cycles frequently, there may be air in the system. Re-prime the pump and check all connections for air leaks.
  4. Funzionamento normale: The pump will automatically turn on when water is drawn from the system and the pressure drops, and turn off when the pressure reaches its set maximum.
  5. Chiudere: To temporarily shut down the pump, turn off the electrical power. For extended periods of non-use, drain the pump and plumbing lines to prevent freezing.

Manutenzione

Una manutenzione regolare garantisce la longevità e il funzionamento efficiente della pompa.

  • Ispezione annuale: Annually inspect all plumbing connections for leaks and tighten as necessary. Check electrical connections for corrosion or damage.
  • Controllo del serbatoio di pressione: Periodically check the air pre-charge in the pressure tank. This should be done when the tank is empty of water and the pump is off. Refer to the pressure tank's specific instructions for the correct pressure.
  • winterization: In areas subject to freezing temperatures, the pump and all exposed plumbing lines must be drained completely to prevent damage from ice expansion.
  • Pulizia: Keep the pump and motor free of dirt and debris to ensure proper cooling.

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
La pompa non si avvia o non funziona.No power; tripped circuit breaker; faulty wiring; motor overload.Check power supply; reset breaker; inspect wiring; allow motor to cool and reset thermal protection.
Pump runs but no water or low pressure.Pump not primed; air leak in suction line; low water level in well; clogged impeller.Re-prime pump; check all suction connections for leaks; verify well water level; inspect and clear impeller.
La pompa si accende e si spegne frequentemente.Waterlogged pressure tank; air leak in system; faulty pressure switch.Check and adjust pressure tank air charge; inspect for leaks; test or replace pressure switch.
La pompa è rumorosa.Air in pump; cavitation; worn bearings.Re-prime pump; ensure adequate water supply; contact qualified service technician for bearing issues.

Specifiche tecniche

CaratteristicaSpecificazione
MarcaTAMBURO
Numero di modello63407
Potenza1 CV
Portata massima950 GPH (15.83 galloni al minuto)
Scarico1 pollici
Sollevamento totale della testa115.5 piedi
Maximum Well Depth26 piedi
Pressione massima dell'acqua50 bar
Capacità del serbatoio5 gal. (hardened steel alloy)
Voltage120 Volt (CA)
MaterialeStainless Steel (housing and volute), Rubber
Peso dell'articolo32.5 libbre
Dimensioni (confezione)21 x 18 x 11 pollici
Protezione termicaRipristino automatico

Garanzia e supporto

This DRUMMOND product is backed by a manufacturer's warranty. Please refer to the warranty card included with your purchase for specific terms and conditions, including coverage duration and limitations. Keep your proof of purchase for warranty claims.

For technical assistance, troubleshooting beyond this manual, or warranty service, please contact DRUMMOND customer support. Contact information can typically be found on the product packaging or the manufacturer's official websito.

Note: Protection plans may be available for extended coverage. Check with your retailer for details.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.