Genasun GV-5-Pb-12V

Genasun GV-5-Pb-12V MPPT Solar Charge Controller for 12V Lead-Acid Batteries - Instruction Manual

Model: GV-5-Pb-12V | Brand: Genasun

1. Prodotto finitoview

The Genasun GV-5-Pb-12V is a high-speed Maximum Power Point Tracking (MPPT) solar charge controller designed for 12V lead-acid batteries. It features a 5A charging current and a 5A DC load output with Low Voltage Disconnect (LVD). This controller is built for efficiency and durability, offering advanced electronic protections and a multi-stage carica profile to optimize battery health and lifespan.

  • Max. recommended panel power: 65 W
  • Corrente di carica: 5 A
  • Multi-stage carica profile for Lead-Acid batteries
  • High-Speed MPPT: 15 Hz (15 times per sec.) tracking speed
  • Efficienza di picco: 99.85%
  • Tiny night consumption: 0.125 mA
  • DC Load Output: 5 A with LVD (low voltage scollegare)
  • Advanced electronic protections for reverse panel and battery polarity
  • Garanzia di 10 anno
  • Made in the USA, conform to CE, FCC, RoHS
Video 1: Unboxing e fineview of the Genasun GV-5 Buck MPPT charge controller, highlighting its features, specifications, and applications. This video provides a comprehensive introduction to the product.
Comparison table of Genasun GV-5 features versus other controllers
Figure 1: A comparison table illustrating the superior features of the Genasun GV-5, such as MPPT tracking speed, efficiency, trickle charge capability, low self-consumption, and radio frequency silence, compared to other controllers.

2. Informazioni sulla sicurezza

Please read all instructions carefully before installation and operation. Failure to follow these instructions may result in damage to the unit, battery, or solar panel, and may void the warranty. Ensure all connections are secure and correct polarity is observed.

  • Always connect the battery to the charge controller FIRST.
  • Always disconnect the solar panel from the charge controller FIRST before disconnecting the battery.
  • Ensure proper ventilation around the charge controller.
  • Do not expose the controller to water or excessive moisture unless it is a waterproof model.
  • Utilizzare cavi di sezione adeguata per tutti i collegamenti per evitare il surriscaldamento.

3. Configurazione e installazione

Follow these steps for proper installation of your Genasun GV-5-Pb-12V solar charge controller.

3.1 Schema elettrico

Wiring diagram for Genasun GV-5 solar charge controller
Figure 2: Wiring diagram showing connections for solar panel, battery, and DC load to the Genasun GV-5 controller. The multicolor LED indicates operational status.

This diagram illustrates the correct connection sequence for your solar panel, battery, and optional DC load. Ensure positive (+) and negative (-) terminals are correctly matched.

3.2 Fasi di connessione

  1. Collegare la batteria: First, connect the battery to the charge controller. Ensure correct polarity (positive to positive, negative to negative). The controller will power on and display the battery voltage.
  2. Seleziona il tipo di batteria: If your controller has a battery type selection feature, press and hold the leftmost button until the battery type indicator flashes. Select the appropriate battery type (e.g., Lead-Acid, AGM, Gel). For Lead-Acid batteries, selecting AGM is often suitable.
  3. Collegare il pannello solare: Next, connect the solar panel to the charge controller. Ensure correct polarity. The controller will begin charging the battery if sufficient solar power is available.
  4. Collegare il carico CC (facoltativo): If using the optional DC load output, connect your DC load (e.g., lights, fan) to the LOAD terminals. The controller's Low Voltage Disconnect (LVD) feature will protect the battery from over-discharge.

3.3 Guida all'installazione visiva

Video 2: A step-by-step guide demonstrating the connection method for a solar charge controller to a battery, optional mobile phone charging, and a solar panel. This video provides a clear visual aid for the installation process.
Video 3: This video illustrates the wiring process for a solar charge controller, showing how to connect the battery, solar panel, and DC load. It serves as a helpful visual reference for correct wiring.

4. Istruzioni per l'uso

Once correctly installed, the Genasun GV-5-Pb-12V operates automatically. The multicolor LED provides status indications:

  • LED verde: Indicates normal operation and charging status.
  • LED rosso: Indicates an error or fault condition. Refer to the troubleshooting section for details.
  • Volume batteriatage Visualizzazione: The integrated display shows the current battery voltage, allowing you to monitor the charge level.

The MPPT technology continuously tracks the maximum power point of your solar array to ensure optimal charging efficiency, even in varying light conditions.

5. Manutenzione

To ensure optimal performance and longevity of your Genasun GV-5-Pb-12V solar charge controller, follow these maintenance guidelines:

  • Ispezione regolare: Controllare periodicamente tutti i collegamenti elettrici per assicurarsi che siano ben saldi e privi di corrosione.
  • Pulizia: Keep the controller clean and free from dust, dirt, and debris. Use a dry cloth for cleaning. Do not use harsh chemicals or abrasive materials.
  • Ventilazione: Assicurarsi che l'area attorno al controller sia ben ventilata per evitare il surriscaldamento.
  • Stato della batteria: Regularly check your battery's condition as per the battery manufacturer's recommendations.

6. Risoluzione Dei Problemi

If you encounter issues with your Genasun GV-5-Pb-12V, refer to the following common troubleshooting tips:

  • Nessuna ricarica:
    • Check all solar panel connections for correct polarity and secure fit.
    • Assicurarsi che il pannello solare riceva un'adeguata luce solare.
    • Verify the battery is properly connected and has sufficient voltage (above the minimum operating voltagE).
  • Indicatore LED rosso:
    • A red LED typically indicates a fault. Check for reverse polarity on either the solar panel or battery connections.
    • Assicurarsi che la batteria voltage is within the acceptable range for the controller.
    • Check for short circuits on the load output.
  • Carico non funzionante:
    • Check connections to the DC load output.
    • Verificare il vol della batteriatage è al di sopra del Low Voltage Disconnect (LVD) threshold. The controller will automatically reconnect the load once the battery voltage recupera.
    • Ensure the load current does not exceed 5A.

If problems persist, contact Genasun customer support for assistance.

7. Specifiche

CaratteristicaDettaglio
Numero di modelloGV-5-Pb-12V
Potenza massima consigliata del pannello65 L
Corrente di carica5 A
Tipo di batteria12 V Lead-Acid Batteries
MPPT Tracking Speed15 Hz (15 times per sec.)
Efficienza massima99.85%
Night Consumption0.125mA
Uscita carico CC5 A with LVD
Temperatura di esercizio-40°C a 85°C
Dimensioni del prodotto4.3 x 2.2 x 0.9 pollici
Peso dell'articolo2.88 once
CertificazioniCertificazione CE, FCC, RoHS
Genasun GV-5-Pb-12V solar charge controller with specifications
Figure 3: The Genasun GV-5-Pb-12V solar charge controller, highlighting its compact design and key features. This image provides a visual representation of the product.

8. Garanzia

The Genasun GV-5-Pb-12V MPPT Solar Charge Controller comes with a Garanzia di 10 anno. This warranty covers defects in materials and workmanship under normal use and service conditions. Please retain your proof of purchase for warranty claims. For detailed warranty terms and conditions, please refer to the official Genasun websito o contattare l'assistenza clienti.

9. Supporto

For further assistance, technical support, or warranty inquiries, please visit the official Genasun website or contact their customer service department. You can find more information and resources at www.genasun.com.

© 2026 Genasun. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.