1. Introduzione
This manual provides essential information for the safe and effective installation and maintenance of the Technical Precision Replacement Bulb for the HACH DR/2000 Spectrophotometer. This product is designed as a direct replacement part to restore or maintain the optimal performance of your HACH DR/2000 instrument.
Si prega di leggere attentamente il presente manuale prima di procedere a qualsiasi installazione o manutenzione. Conservare il manuale per riferimento futuro.
2. Informazioni sulla sicurezza
- Sicurezza elettrica: Always disconnect the HACH DR/2000 instrument from its power source before attempting any installation or maintenance. Failure to do so may result in electric shock or damage to the instrument.
- Componente fragile: The replacement bulb is made of glass and is fragile. Handle with care to prevent breakage. Avoid touching the glass part of the bulb directly with bare hands, as oils can reduce its lifespan. Use gloves or a clean cloth if necessary.
- Calore: The bulb can become very hot during operation. Allow the instrument to cool down completely before handling the bulb.
- Disposizione: Dispose of old bulbs according to local regulations for electronic waste or hazardous materials.
- Personale qualificato: Installation should ideally be performed by qualified personnel familiar with the HACH DR/2000 instrument.
3. Contenuto della confezione
Verificare che tutti gli articoli siano presenti e integri al momento dell'apertura del pacco:
- 1 x Technical Precision Replacement Bulb for HACH DR/2000

This image displays the replacement incandescent bulb, highlighting its tubular shape and the attached electrical connectors, which are essential for installation into the HACH DR/2000.
4. Configurazione e installazione
Follow these steps carefully to replace the bulb in your HACH DR/2000 Spectrophotometer:
- Spegnimento e disconnessione: Ensure the HACH DR/2000 instrument is completely powered off and unplugged from the electrical outlet. Allow sufficient time for the instrument, especially the bulb area, to cool down if it has been recently in use.
- Accesso al vano lampadina: Refer to your HACH DR/2000 user manual to locate and safely open the bulb access compartment. This typically involves removing a cover or panel, often secured by screws.
- Rimuovere la vecchia lampadina: Carefully disconnect the electrical connectors from the old bulb. Gently grasp the old bulb (if it's cool enough) and remove it from its socket or mounting bracket. Note its orientation for correct installation of the new bulb.
- Installare una nuova lampadina: Without touching the glass part of the new Technical Precision bulb, carefully insert it into the socket or mounting bracket, ensuring it is seated correctly. Connect the electrical connectors firmly to the bulb's terminals. Ensure the connections are secure.
- Scomparto sicuro: Close and secure the bulb access compartment, reattaching any screws or covers that were removed.
- Ricollegare l'alimentazione: Plug the HACH DR/2000 instrument back into the electrical outlet.
- Funzionalità di prova: Power on the HACH DR/2000 and perform a diagnostic check or a standard measurement to confirm the new bulb is functioning correctly and providing stable light output.
5. Considerazioni operative
The Technical Precision Replacement Bulb is designed to integrate seamlessly with your HACH DR/2000. Once installed, the spectrophotometer should operate as intended by its original design. The bulb provides the necessary light source for accurate photometric measurements.
- Ensure the instrument is used within its specified environmental conditions.
- Regular calibration of the HACH DR/2000 is recommended to ensure continued accuracy, especially after replacing critical components like the light source.
6. Manutenzione
Proper maintenance of the bulb and surrounding area can extend its lifespan and ensure consistent performance:
- Pulizia: If the bulb needs cleaning (e.g., from accidental fingerprints), gently wipe it with a clean, lint-free cloth moistened with isopropyl alcohol. Ensure the bulb is cool and the instrument is unplugged before cleaning.
- Ispezione: Periodically inspect the bulb and its connections for any signs of wear, discoloration, or loose connections.
- Magazzinaggio: Se si conserva una lampadina di riserva, conservarla nella confezione protettiva originale in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.
7. Risoluzione Dei Problemi
If you encounter issues after installing the replacement bulb, consider the following:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| La lampadina non si accende. |
|
|
| Inconsistent or incorrect readings. |
|
|
8. Specifiche
| Marca | Precisione tecnica |
| Nome del modello | DR/2000-AZ-DQWX-4 |
| Tipo di luce | Incandescent |
| Cosatage | 1 watt |
| Voltage | 230 Volt |
| Forma della lampadina Dimensioni | T (Tubolare) |
| Lunghezza lampadina | 4 pollici |
| Materiale | Copper (for connectors/base) |
| Caratteristica speciale | Alta efficienza |
| Conteggio unità | 1.0 Conteggio |
9. Garanzia e supporto
This Technical Precision replacement part is manufactured to high standards. For specific warranty information regarding this replacement bulb, please refer to the packaging or contact Technical Precision directly via their official websito o canali di servizio clienti.
For support related to the HACH DR/2000 instrument itself, including its operation, calibration, or internal diagnostics, please refer to the original HACH DR/2000 user manual or contact HACH customer support.
Technical Precision Contact:
- Websito: Visit the Technical Precision Store on Amazon
- ID venditore: A1JFPHGOM4BC6O (as listed on Amazon)