The Victron Cyrix-ct 12/24V 120 Amp Battery Combiner is an intelligent, microprocessor-controlled relay designed to automatically connect batteries in parallel when one battery reaches a preset charging voltage. This allows for efficient charging of multiple batteries from a single source. When the voltage drops below a specified level, indicating no active charging, the Cyrix-ct automatically disconnects the batteries, preventing discharge of the starter battery by the auxiliary battery. This device is an effective alternative to diode isolators, which can cause voltage loss during charging. The Cyrix-ct features internal temperature monitoring and voltage spike suppression for enhanced reliability and safety.
2. Caratteristiche principali
- Controllato da microprocessore: Ensures precise and reliable operation.
- Automatic Battery Connection: Connects batteries in parallel for charging when a charging voltage viene rilevato.
- Monitoraggio intelligente della batteria: Prevents repeated switching by monitoring battery status.
- Volume automaticotage Regolazione: Compatible with both 12V and 24V systems without manual configuration.
- Valutazione di corrente elevata: Supports a maximum continuous current of 120 Amps.
- Emergency Parallel Connection: Remote switch activation for emergency parallel connection (e.g., for starting with auxiliary battery).
- Internal Temperature Monitoring: Protects the device from overheating.
- Voltage Spike Suppression: Enhances durability and protects connected systems.

Figura 2.1: Oltreview of Victron Cyrix-ct key features. This image highlights the microprocessor control, maximum charge current, support for two batteries, and ease of installation.
3. Informazioni sulla sicurezza
Please read all safety instructions before installing or operating the Cyrix-ct Battery Combiner. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Always disconnect power from the battery system before installation or maintenance.
- Indossare dispositivi di protezione individuale adeguati, tra cui protezioni per gli occhi e guanti isolanti.
- Assicurarsi che tutti i collegamenti elettrici siano sicuri e adeguatamente isolati per evitare cortocircuiti.
- Installare il dispositivo in un'area ben ventilata, lontano da materiali infiammabili.
- Non esporre il dispositivo all'acqua o a umidità eccessiva.
- This device is designed for 12V or 24V DC systems only. Do not connect to AC power.
- Consult a qualified professional if you are unsure about any part of the installation or operation.
4. Configurazione e installazione
The Cyrix-ct Battery Combiner is designed for straightforward installation. Follow the steps below and refer to the wiring diagram for proper connection.
- Montaggio: Choose a dry, protected location for mounting the Cyrix-ct. Ensure it is easily accessible for wiring.
- Cablaggio:
- Connect the positive terminal of Battery 1 (typically the starter battery) to the "Battery 1 +" terminal on the Cyrix-ct.
- Connect the positive terminal of Battery 2 (typically the auxiliary/house battery) to the "Battery 2 +" terminal on the Cyrix-ct.
- Connect the negative terminals of both batteries to a common ground point. The Cyrix-ct does not require a direct negative connection.
- For optional remote control or emergency start assist, connect a switch between terminal 85 (Start Assist) and a positive source, and terminal 86 to ground. Refer to the diagram for details.
- Fusione: Install appropriate fuses in line with the positive battery cables as close to the batteries as possible. The fuse rating should be suitable for the cable size and the maximum current of the Cyrix-ct (120A).
- Verifica: Double-check all connections for correctness and tightness before applying power.

Figure 4.1: Wiring diagram for the Victron Cyrix-ct. This diagram illustrates how to connect the Cyrix-ct between a starter battery and a domestic battery, including connections to the alternator and an optional start assist switch.

Figure 4.2: Physical dimensions of the Victron Cyrix-ct. The unit measures 80mm (3.2 inches) in length and 46mm (1.8 inches) in width, indicating a compact design.
5. Istruzioni per l'uso
The Cyrix-ct operates automatically to manage the charging of your battery banks. There are no user-adjustable settings required for its primary function.
- Connessione automatica: Quando il voltage on one of the connected batteries rises above a specific threshold (e.g., 13.0V for 12V systems, 26.0V for 24V systems) for a sustained period, the Cyrix-ct will engage, connecting the two battery banks in parallel. This allows the charging source (alternator, shore power charger, solar charger) to charge both batteries simultaneously.
- Automatic Disconnection: Se il volumetage on both batteries drops below a specific threshold (e.g., 12.8V for 12V systems, 25.6V for 24V systems) for a sustained period, the Cyrix-ct will disengage, separating the battery banks. This prevents the auxiliary battery from discharging the starter battery when no charging source is active.
- Start Assist (Optional): If connected, activating the remote switch will force the Cyrix-ct to connect the batteries in parallel for a short period, allowing the auxiliary battery to assist in starting the engine if the starter battery is low.

Figure 5.1: Parallel charging logic of the Victron Cyrix-ct. This image explains that the Cyrix-ct prioritizes the starter battery and engages to allow parallel charging of other batteries once the starter battery reaches a sufficient voltage.
6. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Numero di modello | NT-1231 |
| Marca | Energia Victron |
| Volume di eserciziotage | 12V or 24V DC (auto-sensing) |
| Massima corrente continua | 120 Amps |
| Crank Rating (5 seconds) | 180 Amps |
| Tipo di contatto | Normalmente aperto |
| Materiale di contatto | Rame |
| Modalità operativa | Automatico |
| Peso dell'articolo | 110 grammi |
| Dimensioni (circa) | 80 mm x 46 mm (3.2 pollici x 1.8 pollici) |
| UPC / GTIN | 616913923864, 619639706902, 08719076022145, 08719076034339 |
7. Manutenzione
The Victron Cyrix-ct Battery Combiner is designed to be maintenance-free. However, periodic checks can help ensure optimal performance and longevity.
- Ispezionare le connessioni: Periodically check all wiring connections to ensure they are clean, tight, and free from corrosion. Loose connections can lead to poor performance or overheating.
- Unità pulita: Keep the unit clean and free from dust or debris. Use a dry cloth for cleaning. Do not use solvents or abrasive cleaners.
- Controllo ambientale: Assicurarsi che l'ambiente di installazione rimanga asciutto e rientri nell'intervallo di temperatura di esercizio specificato.
8. Risoluzione Dei Problemi
If you experience issues with your Cyrix-ct Battery Combiner, consider the following common troubleshooting steps:
- Batteries Not Combining:
- Check if the charging source is active and providing sufficient voltage to at least one battery (above the connect threshold).
- Verify all wiring connections are secure and correct, especially the positive connections to both batteries.
- Inspect fuses in the battery lines. A blown fuse will prevent current flow.
- Batteries Not Disconnecting:
- Ensure no charging source is active and the voltage on both batteries has dropped below the disconnect threshold.
- Check for any parasitic loads that might be keeping one battery voltage artificially high.
- Surriscaldamento:
- Ensure the unit is installed in a well-ventilated area and not exposed to direct sunlight or excessive heat.
- Verify that the current draw does not exceed the maximum continuous rating of 120 Amps.
If the problem persists after performing these checks, contact Victron Energy customer support or a qualified technician.
9. Garanzia e supporto
The Victron Cyrix-ct 12/24V 120 Amp Battery Combiner comes with a Garanzia mondiale di 5 anni against defects in materials and workmanship. This warranty covers repairs or replacement of the product under normal use conditions.
For warranty claims, technical support, or further assistance, please contact your authorized Victron Energy dealer or visit the official Victron Energy websito per le informazioni di contatto.
Funzionario Victron Energy Websito: www.victronenergy.com