MICRODOS MP2-B

Manuale di istruzioni del dispositivo di dosaggio MICRODOS MP2-B

Model: MP2-B | Brand: MICRODOS

1. Prodotto finitoview

The MICRODOS MP2-B is a peristaltic dosing pump designed for precise dispensing of cleaning agents in dishwashers. This model operates without an integrated control system, making it suitable for applications where external control is managed. It features a robust Santoprene hose for chemical resistance and reliable performance.

MICRODOS MP2-B Dosing Device

Figura 1: Davanti view of the MICRODOS MP2-B Dosing Device. The device is blue with a clear top cover revealing the peristaltic pump mechanism. It has black hose connections on the front and a power cable connection at the bottom.

Caratteristiche principali:

  • Applicazione: Specifically designed for dishwasher cleaning agent dispensing.
  • Portata: Capable of dispensing at 1.5 liters per hour (1.5 l/h).
  • Suction Height: Maximum suction height of 1.5 meters (1.5m).
  • Giunzione di tubi: Equipped with a ø 4x6mm hose connection.
  • Materiale del tubo flessibile: Utilizes Santoprene for durability and chemical compatibility.
  • Controllare: Operates without an integrated control system.
  • Alimentazione elettrica: 230 V CA.

2. Istruzioni di sicurezza

AVVERTIMENTO: Installation and maintenance of this device must only be performed by qualified personnel. Failure to comply may result in electric shock, equipment damage, or personal injury.

  • Scollegare sempre l'alimentazione prima di procedere all'installazione, alla manutenzione o alla risoluzione dei problemi.
  • Assicurarsi che tutti i collegamenti elettrici siano conformi ai codici e alle normative locali.
  • Wear appropriate personal protective equipment (PPE) when handling cleaning agents.
  • Non utilizzare il dispositivo se danneggiato o malfunzionante.
  • Keep the device away from excessive heat, moisture, and corrosive environments.

3. Configurazione e installazione

This section provides general guidelines for setting up the MICRODOS MP2-B dosing device. Specific installation details may vary based on your dishwasher system and local regulations. Always refer to the dishwasher manufacturer's instructions and consult with qualified personnel.

3.1 Montaggio del dispositivo

  • Choose a secure, dry location near the dishwasher, ensuring easy access for maintenance.
  • Mount the device vertically using appropriate fasteners, ensuring it is level.
  • Allow sufficient space around the device for ventilation and hose routing.

3.2 Collegamenti dei tubi flessibili

  • Connect the suction hose (ø 4x6mm) from the cleaning agent container to the inlet port of the dosing device. Ensure the hose reaches the bottom of the container to prevent air intake.
  • Connect the discharge hose (ø 4x6mm) from the outlet port of the dosing device to the designated cleaning agent inlet on your dishwasher.
  • Secure all hose connections with appropriate clamps per evitare perdite.

3.3 Collegamento elettrico

  • Ensure the power supply is disconnected before making electrical connections.
  • Connect the device to a 230VAC power source. This model operates without integrated control, so it must be connected to an external control system (e.g., dishwasher's dosing signal) to initiate dispensing.
  • Verificare che tutti i collegamenti elettrici siano sicuri e adeguatamente isolati.

4. Funzionamento

The MICRODOS MP2-B dosing device is designed for automatic operation when integrated with a compatible dishwasher control system. It does not have manual controls for dosing adjustments on the unit itself.

4.1 Avvio iniziale

  • After completing all installation steps and verifying connections, ensure the cleaning agent container has sufficient liquid.
  • Restore power to the device and the dishwasher system.
  • Initiate a dishwasher cycle that triggers the dosing signal. The MP2-B should begin drawing and dispensing the cleaning agent.
  • Observe the flow to ensure proper operation and check for any leaks.

4.2 Dosing Adjustment

Dosing quantity and frequency are typically controlled by the external dishwasher system or a separate dosing controller. Refer to your dishwasher's or external controller's manual for instructions on adjusting cleaning agent dosage.

5. Manutenzione

Regular maintenance ensures the longevity and optimal performance of your MICRODOS MP2-B dosing device. Always disconnect power before performing any maintenance.

5.1 Controlli di routine

  • Tubi flessibili: Periodically inspect the suction and discharge hoses for kinks, cracks, or signs of wear. Replace damaged hoses immediately.
  • Connessioni: Check all hose and electrical connections for tightness and integrity.
  • Cleaning Agent Level: Ensure the cleaning agent container has sufficient liquid to prevent the pump from running dry.
  • Testa della pompa: Inspect the peristaltic pump head for any visible wear or residue buildup.

5.2 Sostituzione del tubo peristaltico

The Santoprene peristaltic tube is a wear part and will require periodic replacement depending on usage and the type of cleaning agent. Consult a qualified technician for tube replacement to ensure proper installation and calibration.

6. Risoluzione Dei Problemi

Questa sezione fornisce le procedure di base per la risoluzione dei problemi più comuni. Per problemi più complessi, contattare personale di assistenza qualificato.

ProblemaPossibile causaSoluzione
Pump not dispensingNo power; Clogged hose; Empty cleaning agent container; Faulty external control signal; Worn peristaltic tube.Check power supply; Clear hose obstruction; Refill container; Verify control signal; Replace peristaltic tube.
Dosaggio incoerenteAir in the line; Partially clogged hose; Worn peristaltic tube; Incorrect external control settings.Bleed air from system; Clear hose; Replace peristaltic tube; Adjust external control settings.
PerditaLoose hose connections; Damaged hose; Damaged pump head.Tighten connections; Replace damaged hose; Consult technician for pump head repair/replacement.

7. Specifiche tecniche

ParametroValore
ProduttoreMICRODOS
Modello/Numero parteMP2-B
ApplicazioneDishwasher cleaning agent dosing
Portata1.5 litri/ora
Altezza di aspirazione1.5 metri
Diametro del collegamento del tubo flessibileø 4x6mm
Materiale del tubo flessibileSantoprene
ControllareWithout integrated control
Alimentazione elettrica230 V CA
Batterie incluseNO
Batterie richiesteNO
ASINB073Z8Z2DV

8. Garanzia e supporto

For warranty information and technical support, please contact your MICRODOS product supplier or authorized service center. Keep your purchase receipt and product model number (MP2-B) readily available when seeking support.

This manual is intended for informational purposes only. MICRODOS reserves the right to make changes to product specifications without prior notice.

© 2024 MICRODOS. All rights reserved.

For professional use only. Installation by qualified personnel required.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.