1. Prodotto finitoview
The Genasun GV-10-Li-14.2V is a high-performance Maximum Power Point Tracking (MPPT) solar charge controller designed specifically for 4S Lithium Iron Phosphate (LiFePO4) batteries. It efficiently converts solar panel power to charge your battery system, ensuring optimal performance and longevity.

Immagine 1.1: anteriore view of the Genasun GV-10-Li-14.2V MPPT Charge Controller, showing the model name, battery type, charging current, and LED indicators.
Caratteristiche principali:
- Ricarica ottimizzata: Max. recommended panel power 140 W, 10.5 A charging current, charge profile CC/CV at 14.2 V for 4S LiFePO4 (3.55 V per cell).
- High-Speed MPPT: Features a tracking speed of 15 Hz (15 times per second) for efficient power harvesting.
- Alta efficienza: Achieves 98.3% peak efficiency with a tiny night consumption of 0.9 mA.
- Protezioni avanzate: Includes electronic protections for reverse panel and battery polarity.
- Durata e conformità: Made in the USA, certified cETLus, Class 1 Div.2, and conforms to CE, FCC, RoHS standards.
2. Configurazione e installazione
Proper installation is crucial for the safe and efficient operation of your Genasun GV-10-Li-14.2V charge controller. Follow these steps carefully.
2.1 Schema elettrico

Image 2.1: Wiring diagram for the Genasun GV-10-Li-14.2V controller, illustrating connections for a 4S LiFePO4 battery and a solar panel. The diagram shows the positive and negative terminals for both battery and panel connections, and the location of the multicolor LED indicator.
2.2 Fasi di connessione
- Collegare prima la batteria: Connect the positive (+) and negative (-) terminals of your 4S LiFePO4 battery to the 'BATT' terminals on the charge controller. Ensure correct polarity. The controller will not operate without a battery connected.
- Collegare il pannello solare: Connect the positive (+) and negative (-) terminals of your solar panel to the 'PANEL' terminals on the charge controller. Ensure correct polarity.
- Verifica connessioni: Double-check all connections for correct polarity and secure fastening. Incorrect polarity can damage the unit, although the controller has built-in protection.
The controller is designed for simple plug-and-play operation. Once connected, it will automatically begin tracking the maximum power point of your solar panel and charging the battery.
3. Istruzioni per l'uso
The Genasun GV-10-Li-14.2V operates autonomously once connected. The multicolor LED provides status indications.
3.1 Stato dell'indicatore LED
- Verde (fisso): Battery is fully charged, or the controller is in standby mode (e.g., no solar input, or battery is at float voltagE).
- Verde (lampeggiante): Battery is currently charging. The flash rate may vary with charging intensity.
- Rosso (Solido): Indicates an error condition. This could be due to incorrect wiring, over-voltage from the panel, or a battery fault. Disconnect all power and re-check connections.
3.2 MPPT Operation
The controller continuously tracks the maximum power point of the solar panel to extract the most power available. This high-speed tracking (15 times per second) ensures optimal energy harvest even under rapidly changing light conditions.
4. Manutenzione
The Genasun GV-10-Li-14.2V is designed for minimal maintenance. However, periodic checks can ensure long-term reliability.
- Ispezione visiva: Ispezionare periodicamente il controller e tutti i cavi per verificare la presenza di eventuali segni di danni, corrosione o collegamenti allentati.
- Pulizia: Keep the controller free from dust, dirt, and moisture. Use a dry, soft cloth for cleaning. Do not use harsh chemicals or abrasive materials.
- Ventilazione: Ensure the controller is installed in a location with adequate airflow to prevent overheating, although its design is highly efficient.
5. Risoluzione Dei Problemi
If you encounter issues with your Genasun GV-10-Li-14.2V, refer to the following troubleshooting guide.
- Nessuna attività LED:
- Assicurarsi che la batteria sia collegata per prima e che abbia una carica sufficientetage. The controller requires battery power to operate.
- Controllare la polarità della batteria.
- Red LED (Error):
- Disconnect both the solar panel and the battery.
- Re-connect the battery first, then the solar panel, ensuring correct polarity for both.
- Verificare che il pannello solare voltage non supera il volume massimo di ingresso del controllertage (34 V max).
- Batteria non in carica:
- Check solar panel connections and ensure the panel is receiving adequate sunlight.
- Verificare che la batteria voltage is below the full charge voltage (14.2V). If the battery is already full, the controller will enter standby mode (solid green LED).
- Ensure the solar panel is producing sufficient voltage e corrente.
If problems persist after following these steps, contact Genasun customer support.
6. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Modello | GV-10-Li-14.2 V |
| Tipo di batteria | 4S LiFePO4 (Lithium Iron Phosphate) |
| Corrente di carica | 10.5 A |
| Carica professionalefile | CC/CV at 14.2 V (3.55 V per cell) |
| Potenza massima consigliata del pannello | 140 L |
| Massimo. Pannello voltage(OCV) | 34 Volt |
| MPPT Tracking Speed | 15 Hz (15 times per second) |
| Efficienza massima | 98.3% |
| Night Consumption | 0.9mA |
| Protezioni | Reverse panel and battery polarity |
| Materiale | Metallo |
| Peso dell'articolo | 6.6 once (0.41 libbre) |
| Certificazioni | cETLus, Class 1 Div.2, CE, FCC, RoHS |
| Codice UPC | 650267227261 |
7. Informazioni sulla garanzia
The Genasun GV-10-Li-14.2V MPPT Charge Controller comes with a Garanzia di 5 annoLa presente garanzia copre i difetti di materiali e fabbricazione in condizioni di normale utilizzo. Si prega di conservare la prova d'acquisto per eventuali reclami in garanzia.
8. Supporto
For technical assistance, warranty claims, or further inquiries regarding your Genasun GV-10-Li-14.2V MPPT Charge Controller, please contact Genasun customer support. As a product made in the USA, dedicated support is available to assist you.

Image 8.1: Genasun brand logo.