KEESON ETA23

KEESON Babycare TENS Elle TENS 2

Manuale di istruzioni

1. Introduzione

The KEESON Babycare TENS Elle TENS 2 is a Transcutaneous Electrical Nerve Stimulation (TENS) device designed to provide drug-free pain relief during labor and post-natal recovery. It features dual-channel operation, a contraction timer, and Opti-Max Technology to enhance pain management. This manual provides essential information for safe and effective use of your device.

2. Informazioni e avvertenze sulla sicurezza

Please read all instructions carefully before using the device. Failure to do so may result in injury or improper operation.

  • Non utilizzare se si è portatori di pacemaker o di altri dispositivi elettronici impiantati.
  • Do not use if you have a heart condition or epilepsy.
  • Do not use on broken skin, open wounds, or areas of infection.
  • Do not use near or over the eyes, mouth, front of the neck, or across the chest.
  • Consult your doctor or midwife before use if you have any medical concerns.
  • Tenere fuori dalla portata dei bambini.
  • Questo dispositivo è destinato esclusivamente all'uso esterno.
  • Interrompere l'uso se si avvertono fastidi o reazioni avverse.

3. Contenuto della confezione

All'apertura della scatola, assicurarsi che siano presenti tutti i seguenti elementi:

  • 1 x Elle TENS 2 unit
  • 4 x Self-adhesive electrode pads (50x100mm)
  • 2 x fili conduttori
  • 2 batterie AA (1.5V)
  • 1 x cordino per il collo
  • 1 x Manuale di istruzioni (questo documento)
Elle TENS 2 unit with electrode pads, lead wires, and batteries

Image 3.1: Contents of the Elle TENS 2 package, including the main unit, electrode pads, lead wires, and batteries.

4. Dispositivo suview

Familiarize yourself with the various parts and controls of your Elle TENS 2 unit:

Close-up of Elle TENS 2 front panel with screen and buttons

Immagine 4.1: anteriore view of the Elle TENS 2 device, showing the display screen, control buttons, and branding.

  • Schermo LCD: Shows program mode, intensity levels, contraction timer, and battery status.
  • Pulsante di accensione (Ⓘ): Accende/spegne il dispositivo.
  • Contraction Timer Button: Starts and stops the contraction timer.
  • Opti-Max Button: Activates the Opti-Max function for enhanced pain relief.
  • CH1 Intensity Buttons (+/-): Adjusts intensity for Channel 1.
  • CH2 Intensity Buttons (+/-): Adjusts intensity for Channel 2.
  • Pulsante Modalità: Cycles through available TENS programs.
  • Pulsante di potenziamento: Provides an immediate surge of intensity for acute pain during contractions.
  • CT History Button: Displays the history of recorded contractions.
  • Porte per cavi conduttori: Located at the top of the device for connecting electrode lead wires.
Indietro view of Elle TENS 2 showing battery compartment and neck cord attachment

Immagine 4.2: posteriore view of the Elle TENS 2, illustrating the battery compartment and the attachment point for the neck cord.

5. Impostazione

Follow these steps to prepare your Elle TENS 2 for use:

  1. Inserire le batterie: Aprire il vano batterie sul retro dell'unità. Inserire le due batterie AA, assicurandosi della corretta polarità (+/-). Chiudere bene il vano.
  2. Collegare i cavi conduttori: Plug the lead wires into the ports at the top of the Elle TENS 2 unit. Each lead wire has two pins that connect to two electrode pads.
Elle TENS 2 with lead wires connected to the top ports

Image 5.1: The Elle TENS 2 device with lead wires properly inserted into the top connection ports.

  1. Applicare gli elettrodi: Collegare gli elettrodi ai pin dei cavi. Assicurarsi che il collegamento sia saldo.
  2. Preparare la pelle: Ensure the skin where electrodes will be placed is clean, dry, and free from oils or lotions.
  3. Electrode Placement for Labor: For labor pain relief, place the four electrode pads on your back as shown in the diagram below. Two pads should be placed on either side of the spine, just below the bra line, and the other two pads on either side of the spine, just above the sacrum (lower back). Ensure pads are not touching each other.
Elle TENS 2 connected to four electrode pads

Image 5.2: The Elle TENS 2 unit with all four electrode pads connected via lead wires, ready for application.

For post-natal pain relief, consult your healthcare professional for appropriate electrode placement.

6. Istruzioni per l'uso

Using your Elle TENS 2 device:

  1. Attiva: Press and hold the Power button (Ⓘ) until the display illuminates. The device will start in a default program mode.
  2. Regola intensità: Use the CH1 (+/-) buttons to increase or decrease the intensity for Channel 1 (upper pads) and CH2 (+/-) buttons for Channel 2 (lower pads). Start with a low intensity and gradually increase until you feel a strong, comfortable tingling sensation. Avoid setting the intensity too high, which can cause discomfort.
  3. Seleziona modalità: Press the 'Mode' button to cycle through the available programs. The Elle TENS 2 typically offers different modes (e.g., Burst, Continuous) suitable for various stages of labor. Refer to your midwife's advice on which mode to use.
  4. Contraction Timer: Press the 'Contraction Timer' button at the start of a contraction. Press it again when the contraction ends. The display will show the duration of the contraction and the interval between contractions. Press 'CT History' to view a summary of recent contractions.
  5. Funzione di potenziamento: During a contraction, press the 'Boost' button for an immediate, stronger burst of stimulation to help manage acute pain. Release the button to return to the previous intensity.
  6. Opti-Max Technology: Press the 'Opti-Max' button to activate this feature, which provides an additional level of pain relief by automatically adjusting stimulation parameters.
  7. Spegnere: Press and hold the Power button (Ⓘ) until the display turns off. Always turn off the device before removing electrodes.
Elle TENS 2 device held in a hand, showing its compact size

Image 6.1: The Elle TENS 2 unit comfortably held in a hand, demonstrating its ergonomic design and portability.

7. Manutenzione

Proper care will extend the life of your Elle TENS 2 device:

  • Pulizia: Pulisci il dispositivo con un annuncioamp cloth and mild soap. Do not immerse the unit in water or use abrasive cleaners.
  • Elettrodi: After each use, re-apply the protective film to the electrode pads and store them in a sealed bag to maintain their adhesive quality. Replace pads when they lose their stickiness or become damaged.
  • Sostituzione della batteria: When the battery indicator on the display shows low power, replace both AA batteries with new ones. Remove batteries if the device will not be used for an extended period.
  • Magazzinaggio: Conservare il dispositivo e gli accessori in un luogo fresco e asciutto, lontano dalla luce solare diretta e da temperature estreme.

8. Risoluzione Dei Problemi

If you encounter issues with your Elle TENS 2, refer to the following table:

ProblemaPossibile causaSoluzione
Nessuna sensazione o sensazione debole
  • Batteria scarica
  • Loose lead wire connection
  • I cuscinetti non aderiscono bene
  • Intensità troppo bassa
  • Sostituire le batterie
  • Check lead wire connections
  • Ensure pads are firmly applied; replace if necessary
  • Aumentare gradualmente l'intensità
Display non funzionante
  • Batterie scariche
  • Dispositivo non acceso
  • Sostituire le batterie
  • Tieni premuto il pulsante di accensione
I cuscinetti non si attaccano
  • Skin is oily/dirty
  • Pads are old/worn
  • Pulisci accuratamente la pelle
  • Replace with new electrode pads

Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti.

9. Specifiche

  • Numero modello: ETA23
  • Fonte di energia: 2 batterie AA (incluse)
  • Canali: Doppio canale
  • Dimensioni: Approximately 1 x 1 x 1 cm (device only)
  • Peso: Approximately 497 g (device only)
  • Produttore: Body Clock Healthcare Ltd.
  • Caratteristiche: Contraction Timer, Opti-Max Technology, Boost button

10. Garanzia e supporto

Your KEESON Babycare TENS Elle TENS 2 device is covered by a manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included in your package for specific terms and conditions.

For technical support, troubleshooting assistance, or to purchase replacement parts, please contact your retailer or the manufacturer directly. Contact information can typically be found on the product packaging or the manufacturer's official websito.