TCI E0882-25G

Manuale di istruzioni del prodotto

Prodotto: Ethyl Isobutyrylacetate

Modello: E0882-25G

Marca: TCI America

1. Prodotto finitoview

This manual provides essential information for the safe and effective handling, storage, and use of Ethyl Isobutyrylacetate (E0882-25G) supplied by TCI America.

Ethyl Isobutyrylacetate is an organic reagent primarily intended for laboratory research and development applications. It is a carbonyl compound and a key building block in organic chemistry.

Product packaging for Ethyl Isobutyrylacetate

Image: Typical packaging for TCI America chemical reagents, including Ethyl Isobutyrylacetate.

2. Informazioni e precauzioni di sicurezza

WARNING: This product is for laboratory research use only. It is not intended for human or animal use, or as a component in food, drugs, medical devices, cosmetics, or pesticides.

Always consult the Safety Data Sheet (SDS) for comprehensive safety information before handling this chemical. Key precautions include:

  • Wear appropriate Personal Protective Equipment (PPE), including safety goggles, gloves, and a lab coat.
  • Work in a well-ventilated area or under a fume hood to avoid inhalation of vapors.
  • Evitare il contatto con la pelle, gli occhi e gli indumenti. In caso di contatto, sciacquare immediatamente con abbondante acqua e consultare un medico.
  • Non ingerire. In caso di ingestione, consultare immediatamente un medico.
  • Tenere il contenitore ben chiuso quando non in uso.
  • Conservare lontano da materiali incompatibili.

3. Specifiche del prodotto

Detailed chemical and physical properties of Ethyl Isobutyrylacetate (E0882-25G):

ProprietàValore
Nome chimicoEthyl Isobutyrylacetate
Numero CASNumero di telefono: 7152-15-0
Numero MDLMFCD00009198
Purity (GC)>95.0%
Formula molecolareC8H14O3
Peso molecolare158.20
Punto di ebollizione90 °C
SinonimiIsobutyrylacetic Acid Ethyl Ester, Ethyl 4-Methyl-3-oxovalerate, 4-Methyl-3-oxovaleric Acid Ethyl Ester
Chemical structure of Ethyl Isobutyrylacetate

Image: Chemical structure of Ethyl Isobutyrylacetate (C8H14O3).

4. Manipolazione e stoccaggio

4.1. Receiving and Initial Inspection

Upon receipt, inspect the packaging for any signs of damage or leakage. Ensure the product label matches the order and the container is sealed. Store immediately according to recommended conditions.

4.2. Condizioni di conservazione

Store Ethyl Isobutyrylacetate at a temperature range of 15-25 °C (room temperature). Keep the container tightly closed in a dry, well-ventilated place. Protect from light and moisture. Ensure storage area is secure and accessible only to authorized personnel.

4.3. General Handling Guidelines

  • Handle with care to prevent spills.
  • Utilizzare vetreria e attrezzature pulite e asciutte.
  • Avoid cross-contamination with other chemicals.
  • Always return unused material to its original container if possible, or dispose of properly.

5. Linee guida per l'utilizzo

Ethyl Isobutyrylacetate is used as an organic reagent in various chemical synthesis and research applications. Specific usage protocols will depend on the intended experimental design.

5.1. Applicazione

This chemical is categorized under Organic Reagents and Carbonyl Compounds [Non-Heterocyclic Building Blocks]. It serves as a versatile building block for synthesizing more complex organic molecules.

5.2. Purity Considerations

The product is supplied with a purity of >95.0% (GC). For sensitive applications, users should consider verifying purity before use. Impurities may affect reaction outcomes.

6. Emergency Procedures and Disposal

6.1. Spill Response

In case of a spill, immediately evacuate the area if necessary and ensure proper ventilation. Wear appropriate PPE. Absorb the spilled material with an inert absorbent (e.g., sand, vermiculite, diatomaceous earth). Collect in a suitable container for disposal. Do not allow product to enter drains or watercourses.

6.2. Primo soccorso

  • Inalazione: Move to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Get medical attention.
  • Contatto con la pelle: Wash off with soap and plenty of water. Consult a physician if irritation develops.
  • Contatto visivo: Rinse thoroughly with plenty of water for at least 15 minutes and consult a physician.
  • Ingestione: Do NOT induce vomiting. Never give anything by mouth to an unconscious person. Rinse mouth with water. Consult a physician.

6.3. Smaltimento dei rifiuti

Dispose of contents and container in accordance with local, regional, national, and international regulations. Chemical waste should be handled by licensed waste disposal contractors.

7. Esclusione di responsabilità legale

TCI America's products are intended primarily for laboratory use and, unless otherwise indicated on TCI America's invoice, other writings, or on product labels, are not to be used for other purposes, including, but not limited to, human or animal use, or a component in, a food, drug, or medical device (including in vitro diagnostic reagents) or cosmetics as defined in the Federal Food, Drug and Cosmetic Act, as amended, nor as a pesticide as defined in the Federal Insecticide, Fungicide and Rodenticide Act, as amended. Buyer acknowledges that the products purchased hereunder have not been tested by TCI America for safety and efficacy in a food, drug, cosmetic or pesticide unless otherwise stated by TCI America in writing furnished to Buyer. Buyer expressly represents and warrants to TCI America that Buyer will properly test, use, manufacture and market any products purchased from TCI America. For full disclaimer, see TCI Terms and conditions.

8. Supporto e contatto

For technical support, product inquiries, or to access the Safety Data Sheet (SDS), please visit the official TCI America website or contact their customer service. TCI America is a division of Tokyo Chemical Industry, offering a wide range of high-quality organic reagents for research and development.

Assortment of TCI America chemical products

Image: A selection of chemical products from TCI America.

Puoi trovare maggiori informazioni e dettagli di contatto visitando il TCI Store on Amazon o la loro società ufficiale websito.

© 2025 TCI America. Tutti i diritti riservati.

This manual is subject to revision. Please refer to the latest version available from TCI America.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.