1. Introduzione
The BTMETER BT-90EPD Auto-Ranging Digital Multimeter is designed for troubleshooting electrical problems in a wide array of industrial and household devices. It is compact, lightweight, durable, and easy to operate. This multimeter can measure AC/DC current, AC/DC voltage, resistance, continuity, transistor, and diodes with high accuracy. It features Bluetooth connectivity for real-time data transmission to mobile phones (iOS & Android) and allows data export to Excel files. The device is CATIV 600V / CATIII 1000V certified for safety.
Key features include an auto-backlit LCD display for dark environments, attachable test leads, a stand for hands-free use, and protective rubber corner guards for drop protection.
2. Contenuto della confezione
Dopo aver aperto la confezione, verificare che tutti gli articoli elencati di seguito siano presenti e in buone condizioni:
- 1x BTMETER BT-90EPD Digital Multimeter
- 1x 9V (6F22) Battery (Pre-installed)
- 1x Pair of High-Quality Test Leads (Red and Black)
- 1x sonda di temperatura
- 1x Manuale utente
- 1x Custodia per il trasporto

Image: Contents of the BTMETER BT-90EPD package.
3. Prodotto finitoview e controlli
Familiarize yourself with the components and controls of your BT-90EPD multimeter.

Image: Front panel of the BT-90EPD multimeter with labeled controls and input jacks.
- Schermo LCD: Mostra le letture delle misurazioni, le unità e gli indicatori di funzione.
- Tasto SELECT: Toggles between different measurement modes within a rotary switch position (e.g., AC/DC voltage, diodo/continuità).
- Tasto HOLD: Blocca la lettura corrente del display. Premere di nuovo per rilasciare.
- Chiave RANGE: Switches between auto-ranging and manual ranging modes.
- Chiave REL: Activates the relative measurement function, displaying the difference from a stored reference value.
- Hz/% Key: Toggles between frequency and duty cycle measurements.
- Interruttore rotante: Seleziona la funzione di misurazione primaria (ad esempio, Voltage, Corrente, Resistenza, Temperatura).
- Sensore CDS: Light sensor for automatic backlight control.
- Jack di ingresso:
- VHzΩ+))|-- Input Jack: Per volumetage, frequency, resistance, continuity, and diode measurements.
- COM and Temperature '-' Input Jack: Common terminal for all measurements and negative input for temperature.
- µAmA/BATT and Temperature '+' Input Jack: Per microampecco, milliampere, battery test, and positive input for temperature.
- Presa di ingresso 20A: Per misurazioni di corrente elevata (fino a 20 A).
4. Impostazione
4.1. Installazione della batteria
The BT-90EPD comes with a pre-installed 9V (6F22) battery. If replacement is needed:
- Assicurarsi che il multimetro sia spento e che i puntali di prova siano scollegati.
- Individuare il vano batterie sul retro dell'unità.
- Svitare la/le vite/i di fissaggio e rimuovere il coperchio della batteria.
- Carefully remove the old battery and replace it with a new 9V (6F22) battery, observing polarity.
- Riposizionare il coperchio della batteria e fissarlo con la/le vite/i.

Image: Back of the BT-90EPD multimeter showing battery compartment access.
4.2. Collegamento dei puntali di prova
Collegare sempre il puntale di prova nero al COM jack. Collegare il puntale di prova rosso al jack di ingresso appropriato in base al tipo di misurazione:
- Per voltage, Resistance, Frequency, Duty Cycle, Diode, and Continuity measurements, connect the red lead to the VHzΩ+))|-- cricco.
- Per microampere (µA), milliampere (mA), and Battery tests, connect the red lead to the µAmA/BATT cricco.
- For high current (up to 20A) measurements, connect the red lead to the 20A cricco.
5. Istruzioni per l'uso
5.1. Misure di base
To perform basic measurements:
- Turn the rotary switch to the desired function (e.g., V~ for AC Voltage, V- per DC Voltage, Ω per Resistenza).
- Connect the test leads to the appropriate input jacks and then to the circuit or component under test.
- Leggere il valore di misurazione sul display LCD.

Image: Measuring resistance with the BT-90EPD multimeter.
5.2. Misurazione della temperatura
Per misurare la temperatura:
- Turn the rotary switch to the Temperature (℃/℉) function.
- Collegare la sonda di temperatura al COM (negative) and µAmA/BATT and Temperature '+' (positive) jacks.
- Posizionare la punta della sonda di temperatura sull'oggetto di cui si desidera misurare la temperatura o al suo interno.
- Read the temperature value on the LCD display. Use the SELECT button to toggle between Celsius and Fahrenheit if available.

Image: Measuring liquid temperature using the BT-90EPD multimeter and its probe.
5.3. Battery Testing (1.5V~12V)
Per testare il volume della batteriatage:
- Ruotare il selettore in posizione BATTE function (usually combined with µA/mA).
- Collegare il puntale nero a COM jack e il puntale rosso al µAmA/BATT cricco.
- Collegare il puntale di prova rosso al terminale positivo della batteria e il puntale di prova nero al terminale negativo.
- Leggi il volume della batteriatage sul display LCD.

Image: Testing a 9V battery with the BT-90EPD multimeter.
5.4. Bluetooth App Connection and Data Logging
The BT-90EPD can connect to your smartphone for remote monitoring and data logging.
- Download the 'iMultimeter' app from your mobile phone's app store (iOS/Android). You can find the app via this link: iMultimeter App.
- Assicurati che il Bluetooth sia abilitato sul tuo smartphone.
- Turn on the BT-90EPD multimeter.
- Open the 'iMultimeter' app on your phone and follow the in-app instructions to connect to your device.
- Once connected, you can remotely monitor measurements, log data, view on-screen graphs, and export data in EXCEL or TXT files.

Image: Screenshots of the iMultimeter mobile application interface.
5.5. Auto Backlight Display
The multimeter features an auto-backlight display that senses ambient brightness and automatically turns the backlight ON or OFF, improving readability in various lighting conditions without manual intervention.
5.6. Conservazione dei dati
Premere il tasto PRESA button to freeze the current reading on the display. This is useful for recording measurements in situations where it's difficult to view the display directly. Press PRESA again to resume live readings.
5.7. Relative Value Measurement
IL REL function allows you to measure a value relative to a stored reference value. Press the REL button to store the current reading as a reference. Subsequent measurements will display the difference from this reference. Press REL again to exit relative mode.
6. Informazioni sulla sicurezza
To ensure safe operation and avoid damage to the meter, observe the following safety precautions:
- Always ensure the multimeter is set to the correct function and range before making a measurement.
- Non applicare mai voltage or current that exceeds the maximum rated input for any function.
- Usare estrema cautela quando si lavora con voltagsuperiori a 60 V CC o 30 V CA RMS, poiché rappresentano un rischio di scossa elettrica.
- Non utilizzare il misuratore se esso o i puntali di prova sembrano danneggiati.
- Ensure the test leads are fully seated in the input jacks.
- Scollegare i puntali di prova dal circuito prima di modificare le funzioni o gli intervalli.
- Per garantire letture accurate, sostituire immediatamente la batteria quando appare l'indicatore di batteria scarica.
- Rispettare tutti i codici di sicurezza locali e nazionali.
7. Manutenzione
7.1. Pulizia
Pulisci la custodia con l'adamp cloth and mild detergent. Do not use abrasives or solvents. Periodically clean the input jacks with a cotton swab and alcohol to prevent poor contact from dirt or moisture.
7.2. Sostituzione della batteria
Refer to Section 4.1 for instructions on replacing the 9V battery when the low battery indicator is displayed.
7.3. Sostituzione del fusibile
If the current measurement function fails, the fuse may need replacement. Fuse replacement should only be performed by qualified personnel. Refer to the specifications for the correct fuse type and rating.
8. Risoluzione Dei Problemi
Se il multimetro non funziona correttamente, verificare quanto segue:
- Nessun display o display debole: Controllare la batteria. Sostituirla se necessario.
- Letture errate:
- Assicurarsi che i cavi di prova siano collegati correttamente ai jack di ingresso appropriati.
- Verify the rotary switch is set to the correct measurement function and range.
- Controllare che i cavi di prova non siano danneggiati.
- Misurazione della corrente non funzionante: Controllare il fusibile.
- Problemi di connessione Bluetooth:
- Ensure Bluetooth is enabled on your phone and the multimeter.
- Restart both the multimeter and the phone app.
- Ensure the phone is within the specified range (32.8 ~ 49.2 ft).
9. Specifiche
| Parametro | Valore |
|---|---|
| Selezione della gamma | Auto Ranging |
| Visualizzazione massima | 4000 Conteggi |
| Volume DCtage | 400 mV ~ 1000 V |
| Volume ACtage | 4V ~ 750V |
| Corrente continua | 400uA ~ 20A |
| Corrente alternata | 400uA ~ 20A |
| Resistenza | 400ohm ~ 40Mohm |
| Capacità | Da 51.2nF a 100uF |
| Frequenza | 5.12 Hz ~ 5.12 MHz |
| Ciclo di lavoro | 0.1% ~ 99.9% |
| Temperatura | -20℃ ~ 1000℃ (-4℉ ~ 1832℉) |
| Auto LCD Backlight | SÌ |
| Protezione da sovraccarico | SÌ |
| Conservazione dei dati | SÌ |
| Test diodi | SÌ |
| Indicazione di batteria scarica | SÌ |
| Spegnimento automatico | SÌ |
| Selezione ℃/℉ | SÌ |
| Valore relativo | SÌ |
| Mobile Phone APP (Bluetooth) | SÌ |
| Test della batteria | 1.5V ~ 12V |
| Test di continuità | SÌ |
| Alimentazione elettrica | 9V (6F22) * 1pcs |
| Peso dell'articolo | 150 grammi |
| Dimensioni del pacco | 9.37 x 5.83 x 2.44 pollici |
10. Garanzia e supporto
BTMETER products are designed for reliability and performance. For warranty information or technical support, please refer to the documentation included with your purchase or contact BTMETER customer service directly. Contact details can typically be found on the official BTMETER websito o tramite il tuo rivenditore.