Lithonia Lighting ELM2L M12

Lithonia Lighting Quantum ELM2L M12 Emergency Light User Manual

Model: ELM2L M12 | Brand: Lithonia Lighting

1. Introduzione e oltreview

The Lithonia Lighting Quantum ELM2L M12 is a contemporary LED emergency light designed to provide reliable illumination during power outages. This unit features two adjustable LED lamp heads, delivering a combined 220 lumens for effective light distribution in various commercial and industrial settings.

Le caratteristiche principali includono:

  • 90 Minutes of Illumination: Provides emergency lighting for 90 minutes upon power loss.
  • Aimable LED Lamp Teste: Two 1.2W white LED lamp heads with a 10-year typical lifespan, offering 220 total lumens.
  • Costruzione durevole: Flame-rated 5VA thermoplastic housing, impact-resistant white casing.
  • Integrated Test Switch: Features an integrated test switch and bi-color LED status indicator for easy system checks.
  • Maintenance-Free Battery: Rechargeable nickel-cadmium battery requires no maintenance.
  • Installazione semplice: Designed for surface mounting on walls or ceilings, fitting standard junction boxes.
  • Doppio volumetage: Compatible with 120/277V electrical systems.
  • Conformità: UL listed, meets UL 924, NFPA 101, NEC, Title 20, and OSHA standards.
Lithonia Lighting Quantum ELM2L M12 Emergency Light, front view
Figura 1: Fronte view of the Lithonia Lighting Quantum ELM2L M12 Emergency Light.

2. Informazioni sulla sicurezza

Read all instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other hazards, which could cause property damage, personal injury, or death.

  • Sicurezza elettrica: All wiring should be performed by a qualified electrician in accordance with national and local electrical codes. Ensure power is disconnected at the circuit breaker before installation or servicing.
  • Utilizzo del prodotto: This product is intended for indoor damp locations (50°F to 104°F / 10°C to 40°C). Do not use in hazardous locations or with dimmers.
  • Sicurezza della batteria: The unit contains a nickel-cadmium battery. Dispose of batteries properly according to local regulations.
  • Avvertenza sulla Proposta 65: Questo prodotto può contenere sostanze chimiche note allo Stato della California come causa di cancro e difetti alla nascita o altri danni riproduttivi.

3. Contenuto della confezione

Verificare che tutti i componenti siano presenti e integri all'apertura della confezione:

  • Lithonia Lighting Quantum ELM2L M12 Emergency Light Fixture
  • Hardware di montaggio (viti, dadi per cavi)
  • Manuale di istruzioni

4. Installazione

The ELM2L M12 is designed for easy surface mounting on walls or ceilings. The back plate is compatible with most standard junction boxes.

4.1 Fasi di montaggio

  1. Scollegare l'alimentazione: Prima di iniziare l'installazione, disattivare l'alimentazione elettrica tramite l'interruttore automatico.
  2. Remove Back Assembly: Carefully remove the back assembly from the main body of the fixture.
  3. Collegare il cablaggio: Hold the back plate up to the junction box. Use wire nuts to connect the fixture wires to the junction wires: green to green (ground), black to black, and white to white.
  4. Piastra posteriore sicura: Push excess wires into the junction box. Align the keyholes on the back of the fixture housing with the junction box screw holes. Lift the fixture up, install screws, and tighten them to secure the housing assembly to the wall or ceiling.
  5. Collegare la batteria: Within the main housing, connect the battery plug to the charger board. Ensure the battery cable is routed to avoid interference with the AC input connector or other components. The plug-and-play design allows for easy replacement of components.
  6. Re-install Main Body: Re-install the main body of the fixture onto the secured back plate.
  7. Ripristina alimentazione: Turn on electricity at the circuit breaker.
Parte inferiore view of the emergency light showing the mounting plate and wiring access.
Figura 2: parte inferiore view of the ELM2L M12, illustrating the mounting plate and wiring access points.
Diagram showing the dimensions of the Lithonia Lighting Quantum ELM2L M12 Emergency Light.
Figure 3: Product dimensions: 9.72" L x 3.10" W x 4.68" H.

4.2 Video di installazione

Video 1: This video provides a visual guide for installing the ELM2L Emergency Lighting fixture, demonstrating the steps from unboxing to final mounting and wiring connections.

5. Istruzioni per l'uso

Once installed and power is restored, the emergency light will begin charging its internal battery. The bi-color LED status indicator will show the charging status.

5.1 Manual Testing

The unit is equipped with a manual test switch. Press and hold the test button to initiate a manual test. The LED lamp heads should illuminate, indicating that the battery backup system is functional. Release the button to return to normal operation.

Regular testing is crucial to ensure the unit operates correctly during an emergency. Refer to local codes for recommended testing frequency (e.g., monthly 30-second tests, annual 90-minute discharge tests).

6. Manutenzione

The ELM2L M12 emergency light is designed for minimal maintenance. The nickel-cadmium battery is maintenance-free.

  • Pulizia: Periodically clean the exterior of the fixture with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sostituzione della batteria: While designed for a long lifespan, batteries may eventually require replacement. The plug-and-play design facilitates easy battery replacement by a qualified technician.
  • Lamp Regolazione della testa: I due LED lamp heads are aimable. Adjust them as needed to direct light to the required egress path.

7. Risoluzione Dei Problemi

If the emergency light is not functioning as expected, refer to the following common issues and solutions:

ProblemaPossibile causaSoluzione
Unit does not illuminate during power outage o test.No AC power; Battery not connected or faulty; Battery not charged.Check circuit breaker. Ensure battery is properly connected. Allow 24 hours for initial charge. Replace battery if necessary.
LED indicator is off or red.No AC power; Battery fault; Charger fault.Check AC power. Perform battery test. If issue persists, contact customer support.
Emergency lights dim quickly.Battery not fully charged; Battery nearing end of life.Ensure unit is connected to continuous AC power. Replace battery if it fails to hold a charge.

8. Specifiche

CaratteristicaDettaglio
Numero di modelloELM2L M12
MarcaIlluminazione Lithonia
Dimensioni (L x P x A)9.72" x 3.10" x 4.68"
Peso1.31 libbre
ColoreBianco
MaterialeTermoplastico
Sorgente luminosaLED (2 aimable lamp teste)
Luminosità220 lumen (totali)
Cosatage2.4 watt
VoltageDoppio voltaggio 120/277Vtage
Tipo di batteriaNickel-Cadmium (maintenance-free)
Operazione di emergenza90 minuti
Tipo di montaggioMontaggio a soffitto, montaggio a parete
Temperatura di esercizioda 50°F a 104°F (da 10°C a 40°C)
CertificazioniUL Listed, UL 924, NFPA 101, NEC, Title 20, OSHA

9. Garanzia e supporto

The Lithonia Lighting Quantum ELM2L M12 Emergency Light comes with a Garanzia limitata del produttore di 5 anno. For warranty claims or technical support, please visit the official Lithonia Lighting websito o contattare il loro servizio clienti.

For more detailed product information and support resources, visit: litonia.acuitybrands.com

9.1 Prodotto finitoview Video

Video 2: Questo video fornisce una panoramica generaleview of emergency lighting products, including features and benefits relevant to the ELM2L M12.

9.2 Quantum vs. Basics Comparison Video

Video 3: This video compares the Quantum series, including the ELM2L M12, with Lithonia Lighting Basics products, highlighting differences in coverage and application suitability.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.