1. Introduzione
The RIGOL DS1054Z is a 4-channel digital oscilloscope offering a 50MHz bandwidth, 1GSa/s real-time sampling rate, and a 24Mpt record length. It incorporates RIGOL's innovative UltraVision technology to provide advanced display and analysis capabilities. This manual provides essential information for the proper setup, operation, and maintenance of your DS1054Z oscilloscope.
2. Caratteristiche principali
- 50 MHz bandwidth with 4 analog channels.
- Fino a 1 GSa/s in tempo realeamptasso di ling.
- Standard 12 Mpts memory depth, upgradeable to 24 Mpts.
- Innovative UltraVision technology for enhanced signal visibility.
- Waveform capture rate up to 30,000 wfms/s.
- 7-inch WVGA (800x480) display with multi-level intensity grading.
- All-in-one signal debugging and emulation.
- Accelerated analysis and debugging for I2C, RS232, and SPI designs.
3. Prodotto finitoview
Questa sezione fornisce una panoramica visiva e funzionaleview of the RIGOL DS1054Z Digital Oscilloscope.

Figura 1: Fronte view of the RIGOL DS1054Z Digital Oscilloscope, showing the display, control panel, and input channels.

Figura 2: Posteriore view of the RIGOL DS1054Z Digital Oscilloscope, displaying power input, USB, LAN, and auxiliary output ports.
4. Impostazione
- Disimballaggio: Carefully remove the oscilloscope and all accessories from the packaging. Verify that all included components (power cord, USB cable, 4x 150MHz probes) are present.
- Collegamento elettrico: Connect the provided power cord to the AC input on the rear panel of the oscilloscope and then to a suitable AC power outlet (100 V~240 V).
- Accensione: Press the power button located on the front panel to turn on the device. The display will illuminate, and the system will initiate its startup sequence.
- Connessione sonda: Connect the 150MHz probes to the desired input channels (CH1-CH4) on the front panel. Ensure a secure connection.
- Initial Probe Compensation: Before taking measurements, it is recommended to perform probe compensation to ensure accurate readings. Refer to the detailed user guide for specific instructions on probe compensation.
5. Istruzioni per l'uso
This section covers basic operational procedures for the DS1054Z oscilloscope.
5.1 Acquisizione di base della forma d'onda
- Segnale di connessione: Collegare la sonda alla sorgente del segnale che si desidera misurare.
- Seleziona canale: Press the corresponding channel button (e.g., CH1) to enable the channel.
- Configurazione automatica: For a quick display of the waveform, press the AUTO button. The oscilloscope will automatically adjust vertical, horizontal, and trigger settings.
- Regolazioni manuali: Use the vertical scale (V/div) and position knobs for each channel, and the horizontal scale (s/div) and position knobs to fine-tune the waveform display.
5.2 Funzioni di trigger
The DS1054Z offers various trigger types to stabilize and capture specific events.
- Trigger di bordo: Triggers on a rising or falling edge of a signal.
- Trigger di larghezza di impulso: Si attiva con impulsi di una larghezza specificata.
- Trigger di pendenza: Triggers on signals with a specific rise or fall time.
- Attivazione video: Trigger su segnali video standard.
- Trigger del modello: Triggers when a specific logic pattern is met across multiple channels.
- Duration Trigger: Triggers on events lasting a specified duration.
To access trigger settings, press the MENU DI ATTIVAZIONE button and use the soft keys and multi-function knob to configure the desired trigger type and parameters.

Figure 3: Oscilloscope display illustrating various expanded functions and trigger options, including memory depth settings.
5.3 Waveform Record and Playback
The DS1054Z allows for recording and playback of waveforms, which is useful for capturing transient events or analyzing long signal sequences.
- Access Record Function: Navigate to the waveform record menu (refer to the full user manual for exact menu path).
- Configure Recording: Set the desired record length and other parameters.
- Avvia/Interrompi registrazione: Initiate recording to capture waveforms. Stop recording when the desired data is acquired.
- Riproduzione: Utilizzare i controlli di riproduzione per riview the recorded waveforms.

Figure 4: Oscilloscope display showing the interface for waveform recording and playback, including controls for starting, stopping, and reviewing captured data.
6. Specifiche
| Parametro | Specificazione |
|---|---|
| Larghezza di banda analogica | 50 MHz |
| Canali | 4 canali analogici |
| Max. Real-time Sampla tariffa | 1 GSa/s (1 channel), 500 MSa/s (2 channels), 250 MSa/s (3/4 channels) |
| Profondità massima della memoria | 12 Mpts (1 channel), 6 Mpts (2 channels), 3 Mpts (3/4 channels); upgradeable |
| Max. Waveform Capture Rate | 30,000 WFM/s |
| Vertical Input Impedance | 1 MΩ ±2% |
| Vertical Input Range | da 1 mV/div a 10 V/div |
| Horizontal Time Base Range | da 5 ns/div a 50 s/div |
| Standard Trigger Functions | Edge, Pulse Width, Slope, Video, Pattern, Duration |
| Standard Bus Decode | Parallel Bus |
| Interfacce | USB Host & Device, LAN (LXI), AUX Output (Trigger Out, Pass/Fail) |
| Display | 7.0-inch WVGA (800x480) TFT LCD, 64 intensity grading levels |
| Alimentazione elettrica | AC: 100 V~240 V |
| Dimensioni (LxAxP) | Dimensioni: 313.1 mm x 160.8 mm x 122.4 mm |
| Peso | Circa 3.2 kg |
| Accessori inclusi | Power cord, USB cable, 4x 150MHz probes |
7. Manutenzione
- Pulizia: Pulire regolarmente l'esterno dell'oscilloscopio con un panno morbido e asciutto. Per lo sporco ostinato, utilizzare un panno leggermenteampened with water or a mild, non-abrasive cleaner. Avoid using harsh chemicals or solvents.
- Ventilazione: Ensure that the ventilation openings on the device are not obstructed to prevent overheating.
- Magazzinaggio: When not in use for extended periods, store the oscilloscope in a clean, dry environment, away from direct sunlight and extreme temperatures.
- Cura della sonda: Handle probes carefully. Avoid bending or stressing the cables excessively. Store probes properly to prevent damage to the tips and connectors.
8. Risoluzione Dei Problemi
Questa sezione affronta i problemi più comuni che potresti riscontrare con il tuo oscilloscopio.
8.1 No Display After Power On
- Check if the power cord is securely connected to both the oscilloscope and the power outlet.
- Verificare che la presa di corrente funzioni.
- Assicurarsi che il pulsante di accensione sia premuto completamente.
8.2 Unstable Waveform
- Regolare il livello di trigger su un punto stabile sulla forma d'onda.
- Select an appropriate trigger type for the signal being measured (e.g., Edge trigger for periodic signals).
- Check the probe connection and ensure it is properly compensated.
- Verify the input signal's amplitude and frequency are within the oscilloscope's specifications.
8.3 Nessun segnale visualizzato
- Ensure the input channel is enabled (its corresponding button is lit).
- Check the probe connection to the signal source and the oscilloscope.
- Adjust the vertical scale (V/div) to a more sensitive setting.
- Premere il tasto AUTO button to allow the oscilloscope to automatically find the signal.
9. Garanzia e supporto
9.1 Informazioni sulla garanzia
The RIGOL DS1054Z main unit comes with a standard Garanzia di 3 anno from the date of purchase when bought through Amazon. Accessories such as modules, probes, and batteries are covered by a Garanzia di 1 anno. This warranty covers operational defects confirmed by RIGOL Japan. Parallel import products are not eligible for warranty or free support from RIGOL Japan.
In case of a suspected malfunction, after our company confirms that the event is a malfunction, we will provide a replacement with the same product or repair service, or other appropriate response as determined by our company.
9.2 Initial Defect Exchange Policy
Returns are accepted within 14 days of product arrival for initial defects. Return shipping costs for reasons other than operational defects are borne by the purchaser. Questions regarding operational defects or usage are accepted via Amazon email.
9.3 Riparazione e calibrazione
For repair or calibration services, please contact a domestic authorized RIGOL dealer.
9.4 Risorse e supporto aggiuntivi
User guides, datasheets, and software for the DS1054Z can be downloaded from the official RIGOL Japan website. If you require an instruction manual earlier, please contact us via Amazon message.