Easyguard EM209

Easyguard EM209 2-Way Motorcycle Alarm System User Manual

Modello: EM209

1. Introduzione

The Easyguard EM209 is a 2-way motorcycle alarm system designed to enhance the security of your motorcycle. It features a remote control with an LCD screen for real-time monitoring, an integrated shock sensor, and a microwave proximity sensor. This system also offers an optional remote engine start/stop function.

Caratteristiche principali:

  • 2-Way Communication with LCD Remote Pager
  • Remote Engine Start/Stop (Optional)
  • Integrated Shock Sensor Warning
  • Microwave Proximity Sensor Detection
  • Universal compatibility with most 12V DC motorcycles
  • Long remote control range (up to 800 meters in open space)

Important Note: Professional installation is highly recommended for this alarm system. AAA batteries for the remote control are not included and must be purchased separately.

Easyguard EM209 2-Way Motorcycle Alarm System with remote and motorcycle

Immagine 1.1: Passoview of the Easyguard EM209 system highlighting 2-way communication and key features.

2. Configurazione e installazione

2.1 Installazione professionale

Due to the complexity of motorcycle electrical systems, professional installation by a qualified technician is strongly recommended. The system includes a wiring harness and an English user manual with wiring diagrams to assist with installation.

2.2 Installazione della batteria del telecomando

The LCD remote control requires two AAA batteries (not included) for operation. Follow these steps to install or replace the batteries:

  1. Individuare il coperchio del vano batterie sul retro del telecomando.
  2. Press and slide the remote shell cover downwards to open the compartment.
  3. Inserire due batterie AAA nuove, assicurandosi della corretta polarità (+/-).
  4. Far scorrere il coperchio in posizione finché non scatta in modo sicuro.
Easyguard EM209 remote control showing battery compartment and button functions

Image 2.1: The remote control, illustrating the battery replacement process and button layout.

Close-up of Easyguard EM209 remote control battery compartment with arrows indicating slide direction

Immagine 2.2: Dettagliata view of the remote control battery compartment for AAA battery replacement.

3. Istruzioni per l'uso

3.1 Funzioni del telecomando

The remote control features several buttons for operating the alarm system:

  • Arm/Mute Arm Button: Press to arm the alarm. Press and hold for mute arming.
  • Disarm/Remote Engine Stop Button: Press to disarm the alarm. Press and hold to stop the engine if remote start is active.
  • Remote Engine Start Button: Press and hold to remotely start the motorcycle engine (if installed and configured).
  • Panic/Motorcycle Location Button: Press to activate the panic alarm or locate your motorcycle.
Two Easyguard EM209 remote controls, one with an LCD screen and the other showing its back

Image 3.1: The two remote controls included with the Easyguard EM209 system.

3.2 Alarm System Features

The EM209 system provides comprehensive security features:

  • Attiva/Disattiva: Arm or disarm the alarm system.
  • Allarme silenzioso: Arm the system without audible confirmation.
  • Shock Alert: The integrated shock sensor detects impacts and triggers an alert.
  • Microwave Sensor (Proximity): Detects movement around the motorcycle, providing an early warning.
  • ACC-ON Trigger: Triggers an alarm if the ignition is turned on without disarming the system.
  • Pausa allarme: Disattiva temporaneamente l'allarme.
  • Promemoria allarme: Notifies you if the alarm was triggered while you were away.
  • Antifurto: Prevents unauthorized starting of the motorcycle.
  • Avviamento/arresto motore a distanza: Allows starting or stopping the engine remotely (requires proper installation and may need additional relays for some motorcycles).
Motorcycle with blue waves indicating remote engine start function from a remote control

Image 3.2: Illustration of the remote engine start function.

  • Auto Re-arm: If the alarm is accidentally disarmed, it will automatically re-arm after a set period if no action is taken.
  • Motorcycle Location / Panic Mode: Helps locate your motorcycle in a crowded area or deters potential threats.
  • Memoria interna: Retains alarm settings even after power loss.
  • 24-hour Real-time Monitoring: The 2-way remote provides continuous status updates.
  • Emergency Alarm Stop: A method to quickly silence the alarm in an emergency.
  • Indicatore LED: Provides visual status of the alarm system.
  • Indicatore di segnale: Displays signal strength on the remote.
  • Special Music Reminder: Alerts you with a distinct sound for specific events.
  • Current Status Indicator: Shows the current state of the alarm system on the remote's LCD.
  • Impostazione allarme: Allows customization of alarm parameters.
  • Adjustable Transmitter Vibration Sensitivity: Customize the sensitivity of the remote's vibration alerts.
  • Metodo di programmazione: Refer to the detailed wiring diagram and installation manual for programming instructions.

4. Manutenzione

4.1 Sostituzione della batteria del telecomando

As mentioned in the setup section, the remote control requires two AAA batteries. Replace them when the low battery indicator appears on the LCD screen or if the remote's range or responsiveness decreases. Frequent battery changes (e.g., weekly) may indicate high power consumption, which should be monitored.

4.2 Cura generale

  • Keep the main control unit and remote controls dry. Avoid exposure to water or excessive humidity.
  • Do not expose the components to extreme temperatures.
  • Clean the remote control with a soft, dry cloth. Avoid harsh chemicals.
  • Ensure all wiring connections remain secure after installation.

5. Risoluzione Dei Problemi

If you encounter issues with your Easyguard EM209 alarm system, consider the following:

  • Il telecomando non risponde: Check and replace the AAA batteries in the remote control. Ensure you are within the effective operating range.
  • Allarme non attivato: Verify that the system is armed. Check the sensitivity settings for the shock and microwave sensors. Ensure all sensors are properly connected.
  • Falsi allarmi: Adjust the sensitivity of the shock and microwave sensors. Environmental factors (e.g., strong winds, heavy vibrations) can sometimes trigger sensors if set too high.
  • Motorcycle Battery Drain: Some users have reported increased motorcycle battery drain with the alarm installed. Ensure your motorcycle battery is in good condition. If excessive drain occurs, consult with your installer to check the system's power consumption and wiring.
  • Remote Engine Start Not Working: Confirm that this feature was properly installed and configured. Some newer motorcycles may require additional relays or bypass modules.
  • No Display on Remote LCD: Check remote batteries. If the issue persists, the remote may require replacement.

For complex issues, it is recommended to consult the professional who installed the system or contact Easyguard customer support.

6. Specifiche

Numero di modelloModello EM209
MarcaEasyguard
CompatibilitàMost 12V DC Motorcycles
Portata massimaFino a 800 metri (in spazio aperto)
Livello sonoro110 decibel
Telecomando2 units included, with LCD display
Tipo di batteria remota2 batterie AAA (non incluse)
PesoCirca 1.65 libbre (0.75 kg)
ProduttoreEasyguard Electronics co.,ltd
Componenti inclusi1 Control Unit, 2 Remote Controls, 1 Microwave Sensor, 1 Siren, 1 LED Indicator, 1 Wiring Harness
Easyguard EM209 main control unit with dimensions: 94mm height, 71mm width, 28mm thickness

Image 6.1: Dimensions of the Easyguard EM209 main control unit.

Easyguard EM209 alarm siren with red and black casing and wiring

Image 6.2: The siren component of the Easyguard EM209 alarm system.

7. Garanzia e supporto

Warranty information for the Easyguard EM209 system is not provided within this manual. For details regarding warranty coverage, terms, and conditions, please refer to the product packaging, your purchase receipt, or contact the seller or manufacturer directly.

For technical support or assistance with installation and troubleshooting beyond the scope of this manual, please reach out to your professional installer or Easyguard customer service.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.