1. Introduzione
Thank you for choosing the Thermex HIT 10-U Pro Under-Sink Water Heater. This compact and efficient 10-liter, 1500W electric water heater is designed for reliable hot water supply in your kitchen or similar applications. It features a pressure-resistant boiler and an integrated inlet combination valve for safety and ease of installation. Please read this manual carefully before installation and operation to ensure proper use and longevity of your appliance.

Figura 1: Davanti view of the Thermex HIT 10-U Pro water heater, showing the control dial and indicator lights.
2. Istruzioni di sicurezza
Osservare sempre le seguenti precauzioni di sicurezza per ridurre il rischio di incendi, scosse elettriche, lesioni o danni all'apparecchio.
- Leggere tutte le istruzioni prima di utilizzare l'apparecchio.
- Questo apparecchio deve essere installato da un professionista qualificato in conformità con le normative locali.
- Garantire l'alimentazione voltage corrisponde alla targhetta identificativa dell'apparecchio (230 V).
- Non utilizzare lo scaldabagno se il cavo di alimentazione o la spina sono danneggiati.
- Non bloccare la valvola limitatrice di pressione.
- Assicurarsi che l'apparecchio sia adeguatamente messo a terra.
- Non immergere l'apparecchio in acqua o altri liquidi.
- Tenere i bambini e le persone non autorizzate lontano dall'apparecchio durante il funzionamento.
- Scollegare l'alimentazione prima di eseguire qualsiasi operazione di manutenzione o pulizia.
- The water heater is designed for indoor use only.
3. Contenuto della confezione
Verificare che tutti i componenti siano presenti e integri al momento del disimballaggio.
- Thermex HIT 10-U Pro Water Heater unit
- Inlet combination valve (pressure limiting valve and non-return valve)
- Staffa di montaggio
- Viti e tasselli
- Manuale dell'utente (questo documento)

Figura 2: Included installation components: mounting bracket, screws, and the inlet combination valve.
4. Installazione
The Thermex HIT 10-U Pro is designed for under-sink installation with connections facing upwards. Installation should be performed by a qualified professional.
4.1 Montaggio dell'unità
- Choose a suitable location under the sink, ensuring sufficient space for maintenance and connections.
- Mark the drilling points for the mounting bracket on the wall.
- Praticare i fori e inserire i tasselli.
- Fissare saldamente la staffa di montaggio alla parete utilizzando le viti fornite.
- Carefully hang the water heater unit onto the mounting bracket.
4.2 Collegamenti idraulici
- Connect the cold water inlet (blue marking) to the domestic cold water supply using 1/2" fittings.
- Install the provided inlet combination valve on the cold water inlet. This valve acts as both a pressure limiting valve and a non-return valve, essential for safe operation.
- Connect the hot water outlet (red marking) to the hot water tap using 1/2" fittings.
- Assicurarsi che tutti i collegamenti siano ben serrati e senza perdite.
- Fill the water heater with water by opening the hot water tap until water flows freely, indicating the tank is full.
4.3 Collegamento elettrico
- The appliance comes with a 1.5m power cable.
- Connect the power plug to a grounded 230V electrical outlet.
- Assicurarsi che il circuito elettrico sia protetto da un dispositivo di corrente residua (RCD).

Figura 3: Lato view of the water heater, illustrating the compact design and connection points.
5. Funzionamento
5.1 Avvio iniziale
- After installation and filling the tank with water, plug the appliance into the power outlet.
- The "Heating" indicator light on the front panel will illuminate, indicating that the water heater is active and heating the water.
5.2 Controllo della temperatura
- The water heater features a control dial on the front panel.
- Rotate the dial to adjust the desired water temperature. The "ECO" setting provides an energy-efficient temperature.
- The "Heating" indicator light will turn off once the set temperature is reached and will cycle on and off to maintain the temperature.
5.3 Tempo di riscaldamento
The approximate preheating time for the 10-liter tank is 25 minutes to reach the set temperature from cold.
6. Manutenzione
Regular maintenance ensures optimal performance and extends the lifespan of your water heater. Always disconnect the power supply before any maintenance.
- Decalcificazione: Depending on water hardness, periodic descaling of the heating element may be necessary. This should be performed by a qualified technician.
- Inlet Valve Check: Periodically check the inlet combination valve for any blockages or leaks. Ensure the pressure relief function is not obstructed.
- Pulizia: Pulire l'esterno dell'unità con un panno morbido, damp panno. Non usare detergenti abrasivi o solventi.
- Ispezione delle perdite: Regularly inspect all water connections for any signs of leaks.
7. Risoluzione Dei Problemi
Prima di contattare l'assistenza clienti, fare riferimento ai seguenti problemi comuni e alle relative soluzioni.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Niente acqua calda | No power supply; Thermostat set too low; Heating element failure. | Check power connection and circuit breaker; Adjust thermostat setting; Contact a qualified technician. |
| Acqua non abbastanza calda | Thermostat set too low; High hot water demand; Sediment buildup. | Increase thermostat setting; Allow more time for reheating; Consider descaling (professional service). |
| Perdita d'acqua | Loose connections; Faulty inlet valve; Tank damage. | Tighten connections; Inspect and replace inlet valve if necessary; Contact a qualified technician for tank inspection. |
| Rumori forti dall'unità | Accumulo di sedimenti nel serbatoio. | Professional descaling recommended. |
8. Specifiche tecniche
| Caratteristica | Dettaglio |
|---|---|
| Modello | HIT 10-U Pro |
| Capacità | 10 litri |
| Energia | 1500 Watt |
| Voltage | 230 Volt |
| Dimensioni (L x P x A) | Dimensioni: 40 x 36.6 x 30.4 cm |
| Peso (vuoto) | 7 chilogrammi |
| Preheating Time (approx.) | 25 minuti |
| Protezione elettrica | Grado di protezione IPX4 |
| Pressione massima | 6 chilopascal |
| Tipo di connessione | 1/2" fittings |
| Classe di efficienza energetica | B |
| Consumo annuale di elettricità | 559 kWh / anno |
| Sound Power Level (indoors) | 15 dB |

Figura 4: Energy label for the Thermex HIT 10-U Pro, showing efficiency class B and annual consumption.

Figura 5: Product Fiche providing detailed technical information and compliance data. For more details, refer to the EPREL database (ID 1023329).
9. Garanzia e supporto
Thermex provides a warranty for this product:
- Apparecchio: 2 anni di garanzia
- Caldaia: 5 anni di garanzia
For technical support, service, or warranty claims, please contact Thermex customer service:
- Websito: thermex.lv
- E-mail: ankir@thermex.com
- Telefono: +371 29165629
- Indirizzo: Krustpils str. 31, 1073 Riga, Lettland
Please have your model number (HIT 10-U Pro) and purchase date available when contacting support.