1. Introduzione
This manual provides essential information for the safe and effective installation, operation, and maintenance of the PIZZATO FD 1878 Rope Safety Switch. Please read this manual thoroughly before attempting any installation or operation to ensure proper functionality and to prevent potential hazards. Retain this manual for future reference.
2. Informazioni sulla sicurezza
AVVERTIMENTO: Improper installation or use of this device can result in serious injury or death. Always adhere to local and national electrical codes and safety regulations.
- L'installazione e la manutenzione devono essere eseguite esclusivamente da personale qualificato e autorizzato.
- Ensure all power to the machinery is disconnected and locked out before installation, maintenance, or troubleshooting.
- Non bypassare o tamper con l'interruttore di sicurezza.
- Regularly inspect the switch and associated rope for damage or wear.
- The device is designed for industrial applications. Use outside its specified parameters may compromise safety.
3. Prodotto finitoview
The PIZZATO FD 1878 is a robust rope safety switch designed for emergency stop applications on machinery. It features a longitudinal head, a durable metal housing, and silver contacts for reliable operation. The switch is activated by pulling a rope connected to its actuator, providing a safety stop function across a designated area.

Figura 1: The PIZZATO FD 1878 Rope Safety Switch. This image displays the PIZZATO FD 1878 Rope Safety Switch. It features a red and black metal housing, a longitudinal head with a roller actuator, and a blue 'RESET' button. The side of the housing shows the 'Pizzato' logo and various certifications like CE and EAC, along with the model number FD 1878.
Caratteristiche principali:
- Contact Configuration: 1 NO / 1 NC (Normally Open / Normally Closed)
- Temperatura di esercizio: da -25 a 80 gradi Celsius
- Actuator Type: Longitudinal Head
- Materiale della custodia: metallo
- Conduit Entry: One PG 11 conduit entry
- Contacts: Silver contacts for enhanced durability and conductivity
- Action: Slow action mechanism
4. Configurazione e installazione
Before installation, ensure the mounting surface is stable and free from vibrations. The switch should be positioned to allow for clear access to the rope and reset mechanism.
4.1 Montaggio
- Select a suitable mounting location that provides unobstructed access to the safety rope and is within the operational range of the machinery.
- Secure the metal housing of the FD 1878 switch using appropriate fasteners through the designated mounting holes. Ensure the switch is firmly attached to prevent movement during operation.
4.2 Rope Attachment
- Attach the safety rope to the longitudinal head actuator. Ensure the rope is taut but not excessively tight, allowing for proper activation upon pulling.
- Install rope guides and tensioning devices as necessary to maintain proper rope alignment and tension along the protected area.
4.3 Collegamento elettrico
The FD 1878 features one PG 11 conduit entry for electrical wiring. Connect the switch to the control circuit according to the wiring diagram provided with your machinery and local electrical codes.
- Access the internal terminals by removing the cover.
- Connect the control circuit wires to the 1 NO (Normally Open) and 1 NC (Normally Closed) contacts as required by your application.
- Assicurarsi che tutti i collegamenti siano sicuri e adeguatamente isolati.
- Replace the cover and ensure the conduit entry is sealed to maintain the IP67 protection rating.
5. Istruzioni per l'uso
The PIZZATO FD 1878 Rope Safety Switch is designed for emergency stop functionality. When the safety rope is pulled, the switch activates, interrupting the control circuit and stopping the associated machinery.
5.1 Attivazione
To activate the emergency stop function, pull the safety rope. The longitudinal head actuator will move, causing the internal contacts to change state (NO contacts open, NC contacts close), thereby stopping the machinery. The switch employs a slow action mechanism, ensuring reliable contact breaking.
5.2 Ripristino dell'interruttore
After an emergency stop activation, the switch must be manually reset before the machinery can be restarted. Locate the blue 'RESET' button on the switch housing (refer to Figure 1). Push and hold the button until the actuator returns to its original position and the contacts reset. Ensure the cause of the emergency stop has been addressed before resetting and restarting machinery.
6. Manutenzione
Regular maintenance ensures the continued reliable operation of the PIZZATO FD 1878 Rope Safety Switch.
- Ispezione mensile: Visually inspect the switch housing, actuator, and safety rope for any signs of damage, wear, or corrosion. Check the rope tension and ensure it is free from obstructions.
- Test funzionale: Periodically test the switch by activating the emergency stop function and verifying that the machinery stops as intended. Confirm the reset mechanism operates smoothly.
- Pulizia: Keep the switch free from dust, dirt, and debris. Use a soft, dry cloth for cleaning. Do not use abrasive cleaners or solvents.
- Ispezione dei contatti: While the switch uses durable silver contacts, if issues arise, a qualified technician should inspect the internal contacts for wear or contamination.
7. Risoluzione Dei Problemi
If the PIZZATO FD 1878 Rope Safety Switch is not functioning correctly, refer to the following troubleshooting guide:
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Switch does not activate when rope is pulled. | Rope too loose; Actuator obstructed; Internal damage. | Adjust rope tension; Clear obstructions; Inspect switch for damage (qualified personnel only). |
| Switch does not reset. | Reset button stuck; Internal mechanism jammed; Rope still under tension. | Ensure rope is slack; Check reset button for free movement; Inspect internal mechanism (qualified personnel only). |
| Operazione intermittente. | Loose wiring connections; Worn contacts; Environmental factors. | Check and secure all electrical connections; Inspect contacts for wear; Ensure operating environment is within specifications. |
If problems persist after following these steps, contact a qualified technician or PIZZATO customer support.
8. Specifiche
| Parametro | Valore |
|---|---|
| Modello | FD 1878 |
| Configurazione dei contatti | 1 NA / 1 NC |
| Temperatura di esercizio | -25 a 80 gradi Celsius |
| Tipo di attuatore | Longitudinal Head |
| Materiale dell'alloggiamento | Metallo |
| Entrata del condotto | One PG 11 |
| Contatti | Argento |
| Tipo di azione | Slow Action |
| Grado di protezione | Grado di protezione IP67 |
| Certificazioni | CE, EAC, UL (IND.CONT.EQ. A600), GB/T14048.5 |
| Dimensioni del prodotto | 5.91 x 1.57 x 5.91 pollici |
| Peso | 6.56 once |
9. Garanzia e supporto
The PIZZATO FD 1878 Rope Safety Switch is manufactured to high-quality standards and comes with a standard manufacturer's warranty against defects in materials and workmanship. For specific warranty terms, please refer to the documentation provided at the time of purchase or contact PIZZATO directly.
For technical support, spare parts, or further assistance, please contact your authorized PIZZATO distributor or visit the official PIZZATO websito.