Hager EMN001

Hager EMN001 Staircase Time Delay Switch Instruction Manual

Model: EMN001 | Brand: Hager

Introduzione

The Hager EMN001 is a staircase time delay switch designed to control lighting circuits by automatically switching off the lights after a user-defined period. This device enhances energy efficiency and safety in common areas such as stairwells, corridors, and basements. It features an adjustable time delay and a compact design for DIN-rail mounting.

This manual provides essential information for the safe and correct installation, operation, and maintenance of your EMN001 time delay switch. Please read it thoroughly before installation and keep it for future reference.

Informazioni sulla sicurezza

AVVERTIMENTO: Electrical installation should only be performed by a qualified electrician in accordance with national wiring regulations and safety standards. Failure to follow these instructions can result in electric shock, fire, or serious injury.

  • Prima di installare o effettuare la manutenzione del dispositivo, scollegare sempre l'alimentazione dall'interruttore principale.
  • Garantire la fornitura voltage matches the device's rated voltage (230 V).
  • Do not exceed the maximum load capacity of the switch (2300W for incandescent lamps, 16A AC1).
  • Proteggere il dispositivo dall'umidità e dalle temperature estreme.
  • This product is not battery-operated and does not contain hazardous materials requiring special disposal.

Prodotto finitoview

The Hager EMN001 is a compact, modular device designed for integration into electrical distribution boards. Key features include:

  • Ritardo regolabile da 30 secondi a 10 minuti.
  • Two-position switch for permanent ON or timed operation.
  • Pre-warning function for enhanced safety before lights switch off.
  • DIN-rail mounting for easy installation.
Hager EMN001 Staircase Time Delay Switch

Figura 1: Davanti view of the Hager EMN001 Staircase Time Delay Switch, showing the time adjustment dial and the permanent/timed operation switch.

Istruzioni per l'installazione

  1. Disconnessione dell'alimentazione: Before starting any electrical work, ensure the main power supply to the circuit is completely disconnected at the consumer unit/circuit breaker. Verify with a voltagetester.
  2. Montaggio: Mount the EMN001 switch onto a standard DIN rail within an appropriate enclosure.
  3. Cablaggio: Per i collegamenti corretti, fare riferimento allo schema elettrico riportato di seguito.
    • Connect the Live (L) and Neutral (N) supply wires to the corresponding terminals on the switch.
    • Connect the switched Live output to the lighting circuit.
    • Connect the push-button input (if applicable for staircase lighting) to the designated terminal.
    • Assicurarsi che tutti i terminali a vite siano serrati saldamente per evitare collegamenti allentati.
  4. Specifiche del cavo: Use flexible cables with a cross-section of 1 to 6 mm² or solid cables with a cross-section of 1.5 to 10 mm².
  5. Ripristino dell'energia: Una volta che tutti i collegamenti sono sicuri e verificati, ripristinare l'alimentazione al circuito.
Hager EMN001 Wiring Diagram

Figura 2: Wiring diagram for the Hager EMN001 Staircase Time Delay Switch. Shows connections for Live (L), Neutral (N), push-buttons, and lighting loads.

Istruzioni per l'uso

Regolazione del ritardo di tempo

The time delay can be adjusted using the rotary dial on the front of the device. The range is from 30 seconds to 10 minutes. Rotate the dial clockwise to increase the delay time and counter-clockwise to decrease it. Set the desired time according to your application requirements.

Selezione della modalità di funzionamento

The EMN001 features a two-position switch for selecting the operation mode:

  • Timed Mode (Timer Symbol): In this mode, the lights will switch on when a connected push-button is pressed and will automatically switch off after the preset time delay has elapsed. This is the standard mode for staircase lighting.
  • Permanent ON Mode (Light Bulb Symbol): In this mode, the lights will remain continuously on, bypassing the time delay function. This is useful for extended periods of illumination, such as during cleaning or maintenance.

Pre-warning Function

For enhanced safety, the EMN001 includes a pre-warning function. Before the lights switch off completely, they will briefly dim or flash to alert users that the timed period is about to end, allowing them to reactivate the lights if needed.

Manutenzione

The Hager EMN001 time delay switch is designed for maintenance-free operation. However, periodic checks are recommended:

  • Ispezione visiva: Periodically inspect the device for any signs of damage, discoloration, or loose connections.
  • Pulizia: Se necessario, pulire delicatamente l'esterno del dispositivo con un panno asciutto e morbido. Non utilizzare detergenti abrasivi o solventi.
  • Controllo Funzionale: Occasionally test the time delay function and the permanent ON mode to ensure proper operation.

If any issues are detected, disconnect power immediately and consult a qualified electrician.

Risoluzione dei problemi

If you experience problems with your Hager EMN001 switch, refer to the following table:

ProblemaPossibile causaSoluzione
Le luci non si accendono.No power supply, faulty wiring, faulty push-button, or faulty lamp.Check circuit breaker. Verify wiring connections. Test push-button and lamp.
Lights stay on permanently in timed mode.Switch set to permanent ON mode, or a stuck push-button.Ensure the mode switch is set to the timed (timer symbol) position. Check push-buttons for sticking.
Le luci si spengono troppo velocemente o troppo lentamente.Incorrect time delay setting.Adjust the time delay dial to the desired duration.
Pre-warning function not working.Malfunzionamento del dispositivo.Consult a qualified electrician for inspection or replacement.

If the problem persists after attempting these solutions, contact a qualified electrician or Hager customer support.

Specifiche tecniche

ParametroValore
ModelloEMN001
Vol. operativo nominaletage230 V CA
FrequenzaFrequenza 50/60 Hz
Max. Power (Incandescent Lamps)2300 L
Rated Current (AC1)16 A
Time Delay Adjustment RangeDa 30 secondi a 10 minuti
Tipo di connessioneMorsetti a vite
Flexible Cable Cross-section1 - 6 mm²
Solid Cable Cross-section1.5 - 10 mm²
Metodo di montaggioDIN-Rail
Temperatura di esercizioda -10 °C a +55 °C
Temperatura di conservazioneda -20 °C a +60 °C
Grado di protezione IPGrado di protezione IP20
Dimensioni (spedizione)Dimensioni: 8 x 6 x 4 cm
Peso dell'articolo150 grammi
Batterie richiesteNO
Paese di origineFrancia

Garanzia e supporto

Hager products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided with your purchase or visit the official Hager website. In case of technical issues or questions not covered in this manual, please contact your local Hager distributor or customer support for assistance.

Per ulteriori informazioni, è possibile visitare il sito Hager brand page on Amazon.

© 2023 Hager. Tutti i diritti riservati. Le informazioni contenute nel presente manuale sono soggette a modifiche senza preavviso.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.