Commercial Electric WR2440K15LPL

Commercial Electric 24 in. Integrated LED Wraparound Light User Manual

Model: WR2440K15LPL

Introduzione

This manual provides instructions for the installation, operation, and maintenance of your Commercial Electric 24-inch 4000K 1900-Lumen 120-Volt White Integrated LED Wraparound Light. Please read these instructions carefully before installation and retain them for future reference.

Commercial Electric 24-inch Integrated LED Wraparound Light

Image: The Commercial Electric 24-inch Integrated LED Wraparound Light, showcasing its sleek, white design and prismatic lens.

Informazioni sulla sicurezza

AVVERTIMENTO: Risk of electric shock. Disconnect power at the fuse or circuit breaker before installing or servicing. Consult a qualified electrician if you are not familiar with electrical installations.

  • Ensure all connections are made correctly and securely.
  • Questo dispositivo è progettato solo per uso interno.
  • Non tentare di modificare l'apparecchio. Qualsiasi modifica potrebbe invalidare la garanzia e rappresentare un rischio per la sicurezza.
  • Durante l'installazione indossare occhiali e guanti di sicurezza.

Contenuto della confezione

Verificare che tutti i componenti siano presenti prima di iniziare l'installazione.

  • 1 x Commercial Electric 24 in. Integrated LED Wraparound Light
  • Hardware di montaggio (viti, dadi per cavi)
  • Manuale di istruzioni
Product packaging for Commercial Electric LED Wraparound Light

Image: The product packaging for the Commercial Electric 24-inch LED Wraparound Light, indicating the contents and model information.

Configurazione e installazione

This fixture is designed for semi-flush mount installation on a ceiling. Ensure the power is OFF at the circuit breaker before proceeding.

  1. Preparare l'area di installazione: Turn off power at the main circuit breaker. Ensure the mounting surface is structurally sound to support the fixture.
  2. Remove Diffuser and Mounting Plate: Carefully remove the prismatic lens diffuser from the fixture. Locate and detach the mounting plate from the fixture body.
  3. Segnare i fori di montaggio: Hold the mounting plate against the ceiling in the desired location. Mark the positions for the mounting screws.
  4. Installare la piastra di montaggio: Drill pilot holes if necessary. Secure the mounting plate to the ceiling using the provided mounting hardware.
  5. Collegamenti elettrici:
    • Collegare il nero filo dall'apparecchio al nero (live) wire from the junction box.
    • Collegare il bianco filo dall'apparecchio al bianco filo (neutro) dalla scatola di giunzione.
    • Collegare il verde or bare copper wire from the fixture to the verde or bare copper (ground) wire from the junction box.
    • Fissare tutti i collegamenti con i cappucci per cavi.
  6. Fissare il corpo dell'apparecchio: Carefully align the fixture body with the mounting plate and secure it using the screws provided. Ensure no wires are pinched.
  7. Reinstall Diffuser: Reattach the prismatic lens diffuser to the fixture body.
  8. Ripristina alimentazione: Riattivare la corrente tramite l'interruttore automatico.

Istruzioni per l'uso

The Commercial Electric LED Wraparound Light is designed for simple operation.

  • Una volta installata e ripristinata l'alimentazione, la luce può essere accesa o spenta tramite un normale interruttore a parete collegato al circuito dell'apparecchio.
  • This fixture features integrated LEDs and does not require bulb replacement.

Manutenzione

This LED fixture is designed to be maintenance-free. However, occasional cleaning may be required.

  • Pulizia: Assicurarsi che l'alimentazione sia SPENTA prima di pulire. Utilizzare un panno morbido, asciutto o leggermenteamp cloth to wipe the exterior surfaces of the fixture and the prismatic lens. Do not use abrasive cleaners or solvents, as these may damage the finish or lens.
  • Nessuna sostituzione della lampadina: The LEDs are integrated and are not user-replaceable. The fixture has a long operational life of approximately 50,000 hours.

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
La luce non si accende.Nessuna alimentazione al dispositivo.
Collegamento del cablaggio allentato.
Interruttore a parete difettoso.
Controllare l'interruttore automatico e l'interruttore a parete.
Ensure all wire connections are secure (power OFF first).
Testare o sostituire l'interruttore a parete.
Sfarfallio di luce.Collegamento del cablaggio allentato.
Interruttore dimmer non compatibile (se applicabile).
Check and secure all wire connections (power OFF first).
This fixture is not specified as dimmable; ensure it is connected to a standard ON/OFF switch.
L'emissione luminosa è scarsa.Polvere o sporcizia sulla lente.Clean the prismatic lens with a soft, damp cloth (power OFF first).

Specifiche

Numero di modelloWR2440K15LPL
MarcaElettrico commerciale
Dimensioni28 x 6 x 3.6 pollici (confezione)
Peso2.84 libbre
Sorgente luminosaLED integrato
Luminosità1900 lumen
Temperatura del colore4000 Kelvin (bianco freddo)
Voltage120 Volt
Fonte di alimentazioneElettrico con cavo
Tipo di installazioneMontaggio semi-a filo
MaterialePlastica
Uso interno/esternoAl chiuso
Aspettativa di vita50,000 ore
CertificazioniETL Listed, ENERGY STAR

Garanzia

The product description mentions a "Limited" warranty type. For specific warranty details, including duration and coverage, please refer to the warranty card included with your product or contact Commercial Electric customer support.

Assistenza clienti

For technical assistance, replacement parts, or general inquiries, please contact Commercial Electric customer service. Refer to the product packaging or the manufacturer's websito per le informazioni di contatto più aggiornate.

Risorse online: You may find additional support and FAQs on the Commercial Electric official websito.