1. Introduzione

This manual provides detailed instructions for the installation, operation, maintenance, and troubleshooting of the Nohken OLV-2P Liquid Level Sensor. Please read this manual thoroughly before using the product to ensure safe and efficient operation. Keep this manual for future reference.

2. Prodotto finitoview

The Nohken OLV-2P is a reliable liquid level sensor designed for various applications. It operates using a Reed contact installed within its axis and a permanent magnet located in the float. The sensor activates its contact when the liquid level rises or falls, and its switching state (normally open or normally closed) is determined by the direction of installation.

Key features of the OLV-2P sensor include:

  • Good resistance to oils and acids, making it suitable for a wide range of media including acids, oils, gasoline, and water.
  • High switching power, capable of handling up to 0.5 A and up to 10 million switching cycles.
  • Can be switched without an intermediate relay.
  • Maximum temperature load specified at 90 °C.

Typical areas of application include small containers of all types, coffee machines, aquariums, control of small filters, pumps, and photocopiers.

3. Informazioni sulla sicurezza

Per evitare lesioni o danni al prodotto, osservare sempre le seguenti precauzioni di sicurezza:

  • Assicurarsi che l'alimentazione sia scollegata prima dell'installazione, della manutenzione o della risoluzione dei problemi.
  • Do not exceed the specified maximum voltage (300 Volts) or current (0.5 A).
  • Do not expose the sensor to temperatures exceeding 90 °C.
  • Verify compatibility with the liquid media before installation.
  • Installation should be performed by qualified personnel if electrical wiring is involved.

4. Configurazione e installazione

The Nohken OLV-2P sensor is designed for straightforward installation. The key aspect of installation is determining the desired switching state (normally open or normally closed) by the sensor's orientation.

4.1 Disimballaggio e ispezione

Upon receiving your OLV-2P sensor, carefully open the packaging and inspect the unit for any signs of damage. Ensure all components are present.

Nohken OLV-2P liquid level sensor in its packaging box.

Figure 1: The Nohken OLV-2P liquid level sensor, shown resting on its small product box.

4.2 Montaggio del sensore

The sensor is typically mounted through a threaded opening in the wall or top of a container. The float should be positioned to move freely with the liquid level.

Avvicinamento view of the threaded connection point of the Nohken OLV-2P sensor.

Figura 2: Un dettaglio view of the sensor's threaded connection, indicating how it can be secured.

Lato view of the Nohken OLV-2P sensor, showing the float and wiring.

Figure 3: The sensor viewed from the side, illustrating the float's position relative to the main body.

4.3 Determining Switching State

The OLV-2P sensor's switching behavior (whether it acts as a normally open or normally closed contact) is determined by its installation orientation. Experiment with the sensor's position (e.g., float up or float down when liquid is present/absent) to achieve the desired switching logic for your application.

Top-down view of the Nohken OLV-2P sensor, showing the float and coiled wires.

Figure 4: An overhead perspective of the sensor, highlighting the float and the electrical wiring.

4.4 Collegamento elettrico

Connect the sensor's wires to your control circuit. Ensure the voltage and current ratings of your circuit are within the sensor's specifications (max 300V, 0.5A). The sensor can be directly integrated without an intermediate relay if the load is within its switching capacity.

Nohken OLV-2P sensor with its electrical wires extended.

Figure 5: The sensor with its wires laid out, ready for electrical connection.

5. Istruzioni per l'uso

Once installed and connected, the Nohken OLV-2P sensor operates automatically. The float will rise or fall with the liquid level. As the float moves, the permanent magnet inside it will interact with the Reed contact within the sensor's axis, causing the contact to open or close. This change in contact state can then be used to trigger alarms, control pumps, or activate other devices in your system.

No user intervention is required during normal operation, provided the sensor is correctly installed and the liquid properties are within its specified limits.

6. Manutenzione

The Nohken OLV-2P sensor is designed for low maintenance. However, periodic inspection and cleaning are recommended to ensure optimal performance and longevity.

6.1 Pulizia

If the sensor is used in media that can leave residue, periodically remove the sensor and gently clean the float and stem with a soft cloth. For stubborn deposits, use a cleaning agent compatible with the sensor's materials and the liquid being monitored. Ensure the sensor is completely dry before reinstallation.

6.2 Ispezione

Regularly inspect the sensor for any signs of physical damage, corrosion, or wear on the float or wiring. Check that the float moves freely along the stem. If any damage is observed, replace the sensor.

7. Risoluzione Dei Problemi

If you experience issues with your Nohken OLV-2P sensor, consider the following common problems and solutions:

ProblemaPossibile causaSoluzione
Sensor not switchingIncorrect installation orientation (switching state)
Float stuck due to debris/residue
Cablaggio o componente interno danneggiato
Reverse sensor orientation to change NO/NC state
Clean the float and stem
Check wiring for continuity; replace sensor if damaged
Letture incoerentiTurbulence in liquid
Float partially obstructed
Interferenza elettrica
Reduce turbulence if possible
Ensure float moves freely
Shield wiring or move away from interference sources
Sensor leaksSigillatura non corretta durante l'installazione
Alloggiamento rotto
Re-install with proper sealant/gasket
Sostituire il sensore

Se il problema persiste dopo aver provato queste soluzioni, contattare l'assistenza clienti.

8. Specifiche

AttributoValore
ProduttoreNohken
Numero di modelloOLV-2P
Dimensioni del prodotto (L x P x A)Dimensioni: 12.7 x 5.08 x 5.08 cm
Peso27.22 grammi
Voltage Valutazione300 Volt
Max corrente0.5 A
Max Temperature Load90 °C
Quantità di articoli1
Batterie incluse?NO
Sono necessarie batterie?NO

9. Garanzia e supporto

Nohken provides a 1-year availability for spare parts for the OLV-2P sensor. For warranty claims, technical support, or inquiries regarding spare parts, please contact your retailer or the official Nohken support channels. Ensure you have your product model number (OLV-2P) and purchase details ready when contacting support.

© 2025 Nohken. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.