The Sorand AC10 1000V Non-contact AC Voltage Tester is a pen-shaped device designed for safe and easy detection of AC voltage. It features a non-contact design, dual sensitivity ranges, an LED flashlight, and audible/visual alarms to indicate voltage presence. This manual provides essential information for the proper setup, operation, and maintenance of your voltagetester.

Sorand AC10 1000V Non-contact AC Voltage Tester, front view

Figura 1: Fronte view of the Sorand AC10 1000V Non-contact AC VoltageTester.

Impostare

Installazione della batteria

  1. Twist and remove the battery cap at the bottom of the tester.
  2. Inserire due (2) batterie AAA da 1.5 V, assicurandosi della corretta polarità (+/-). Le batterie non sono incluse.
  3. Replace the battery cap by twisting it clockwise until secure.

The device features a battery deficiency indicator. If the batteries are low, replace them promptly to ensure accurate readings.

Istruzioni per l'uso

Accensione/spegnimento

  • Premere il pulsante di accensione verde () to turn the tester on. The device will emit a short beep and the indicator lights may flash.
  • To turn off, press and hold the power button until the device powers down. The tester will automatically shut down after 15 minutes of inactivity.

Vol. AC senza contattotage rilevamento

  1. Assicurarsi che il tester sia acceso.
  2. Place the tip of the tester near the object to be tested (e.g., terminal strip, outlet, supply cord).
  3. Il tester rileverà automaticamente la tensione CAtage senza contatto fisico.
Sorand AC10 1000V Non-contact AC Voltage Tester che rileva il volumetage near a circuit board

Figura 2: Il volumetage tester in use, detecting AC voltage.

Indicazioni di allarme

The tester uses both acoustic (beeping) and visual (light) alarms to indicate detected voltage forza:

  • Alto volumetage: Red light on with rapid beeping sound.
  • Vol. mediotage: Green light on with medium beeping sound.
  • Basso volumetage: Red light on with slow beeping sound.

Dual Measurement Range

The tester supports two AC voltage intervalli di rilevamento:

  • Gamma standard: 48V ~ 1000V AC (default setting).
  • Basso volumetage Gamma: 12V ~ 1000V AC, for more sensitive measurements (e.g., doorbells, thermostats).

To switch between detection ranges, press the 'S' button (S) on the device. The indicator lights will change to confirm the selected range.

Funzione torcia a LED

The built-in LED flashlight assists in working in dark environments:

  • Press the flashlight button (💡) to turn the LED light on.
  • Premere nuovamente il pulsante per spegnere la torcia.
Sorand AC10 1000V Non-contact AC Voltage Tester with flashlight illuminated

Figure 3: The LED flashlight in operation, illuminating a dark area.

Manutenzione

Pulizia

To clean the device, wipe it with a dry, soft cloth. Do not use abrasive cleaners or solvents, as these may damage the casing o componenti interni.

Sostituzione della batteria

Replace batteries when the battery deficiency indicator activates or if the device fails to power on. Always use two new 1.5V AAA batteries.

Magazzinaggio

Conservare il volumetage tester in a cool, dry place away from direct sunlight and extreme temperatures. If storing for extended periods, remove the batteries to prevent leakage.

Risoluzione dei problemi

  • Il dispositivo non si accende: Controllare che le batterie siano installate correttamente e abbiano una carica sufficiente. Sostituirle se necessario.
  • nessun volumetage rilevamento: Ensure the device is powered on. Verify that the tip of the tester is close enough to the AC voltage fonte.
  • Letture incoerenti: Ensure the correct sensitivity range is selected for the application. Low battery power can also affect accuracy.
  • La torcia non funziona: Controllare la carica della batteria.

Specifiche

MarcaSorand
Numero di modelloCA10 1000 V
Materialeaddominali
ColoreNero
Volume ACtage Gamma12V~1000V / 48V~1000V (default)
Modalità allarmeSound light and traffic light alarm
Spegnimento automaticoSì (15 minuti)
Battery Deficiency Indicator
Livello di sicurezzaCATIII 1000V
Energia2 batterie AAA da 1.5 V (NON incluse)
Dimensioni (L x P x A)160 x 28 x 20 mm (6.3 x 1.1 x 0.8 pollici)
Peso46 g (1.6 once)
Codice UPC784911544111
ASINB07X1YFNW2
Sorand AC10 1000V Non-contact AC Voltage Tester with dimensions labeled

Figure 4: Dimensions of the Sorand AC10 1000V VoltageTester.

Garanzia

This product comes with a 100% Quality Warranty. If you are not satisfied with your purchase, you may be eligible for a full refund. Please refer to your purchase documentation for specific warranty terms and conditions.

Supporto

For any questions or assistance regarding your Sorand AC10 1000V Non-contact AC Voltage Tester, please contact our customer service. Our dedicated service team is available to provide support and help resolve any issues you may encounter.

© 2026 Sorand. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.