1. Introduzione
The Prolink PRO901ES is a 1000VA/900W Pure Sine Wave Online Uninterruptible Power Supply (UPS) designed to provide reliable power backup and protection for critical electronic equipment. This UPS features true double-conversion technology, ensuring a consistent and clean power supply. It is suitable for various applications including data centers, medical equipment, office workstations, ATMs, and kiosk machines.

Figure 1: Prolink PRO901ES 1000VA/900W Online UPS, Tower Type.
2. Prodotto finitoview
2.1 Caratteristiche principali
- True Double-Conversion Online Technology: Provides consistent, high-quality AC power regardless of input fluctuations.
- Uscita onda sinusoidale pura: Ensures compatibility with sensitive electronic equipment.
- High Input Power Factor Correction: Improves efficiency and reduces overall power losses.
- Programmable Power Management Outlets: Allows for flexible control over connected devices.
- Emergency Power Off (EPO) Function: Provides an immediate shutdown mechanism for safety.
- Vol. avanzatotage Regolamento (AVR): Regulates output voltage within 1% tolerance, protecting devices from voltage spikes or sags.
- Capacità di monitoraggio: Status can be monitored via the LCD display or PC programs.
2.2 Descrizione del pannello posteriore
The rear panel of the PRO901ES UPS features essential connection ports for power input, output, and communication.

Figure 2: Rear Panel Layout of PRO901ES.
- Ingresso CA: Collega l'UPS all'alimentazione principale.
- Interruttore automatico di ingresso: Fornisce protezione da sovracorrente per l'ingresso.
- Porta di comunicazione USB: For connecting to a computer for monitoring and management.
- Porta di comunicazione RS-232: Another port for computer communication.
- Slot intelligente: For optional network management cards (e.g., SNMP).
- Collegamento batteria esterna: (Only available for 'L' models) For connecting external battery packs to extend runtime.
- Prese di uscita: Three universal sockets for connecting protected devices.

Figure 3: Typical applications for the Prolink PRO901ES UPS.
3. Istruzioni per l'installazione
Follow these steps for initial setup of your Prolink PRO901ES UPS:
- Disimballaggio: Carefully remove the UPS from its packaging and inspect for any damage. Retain packaging for future transport.
- Posizionamento: Place the UPS in a clean, dry, and well-ventilated area, away from direct sunlight or heat sources. Ensure adequate clearance for airflow.
- Carica iniziale: Before connecting any devices, plug the UPS into a standard AC power outlet using the provided power cord. Allow the unit to charge for at least 8 hours to ensure optimal battery performance.
- Dispositivi di connessione: Once the UPS is fully charged, connect your critical electronic devices (e.g., computers, monitors, network equipment) to the output receptacles on the rear panel. Do not overload the UPS beyond its rated capacity (900W).
- Communication Setup (Optional): For advanced monitoring and management, connect the UPS to a computer using a USB or RS-232 cable. Install the necessary software (if provided) to enable communication features.
- Accensione: Press the power button on the front panel to turn on the UPS. The LCD display will illuminate, indicating the operational status.
4. Istruzioni per l'uso
4.1 Accensione/Spegnimento
- Per accendere: Tenere premuto il pulsante di accensione sul pannello frontale finché l'UPS non si accende.
- Per spegnere: Press and hold the power button until the UPS powers off. Ensure all connected devices are safely shut down before powering off the UPS.
4.2 Comprensione del display LCD
The front panel LCD provides real-time information about the UPS status, including input/output voltage, livello della batteria, percentuale di caricotage, and various operational modes.

Figure 4: Monitoring status from the LCD display.
4.3 Spegnimento di emergenza (EPO)
The EPO function allows for an immediate and complete shutdown of the UPS and all connected equipment in an emergency. Refer to the detailed wiring diagram in the full user manual for proper EPO connection.

Figure 5: Zero transfer time ensures continuous operation during power events.

Figure 6: The UPS provides clean power output, mitigating various power issues.

Figure 7: High-Precision AVR regulates output voltage within 1% tolerance.
5. Manutenzione
- Cura della batteria: The UPS uses Lead Acid batteries. To prolong battery life, avoid frequent deep discharges and operate the UPS within recommended temperature ranges. Periodically perform a battery self-test if available through the monitoring software.
- Pulizia: Keep the UPS clean and free from dust. Use a soft, dry cloth to wipe the exterior. Do not use liquid or aerosol cleaners. Ensure ventilation openings are not blocked.
- Magazzinaggio: If storing the UPS for an extended period, ensure it is fully charged and then recharge it every 3 months to prevent battery degradation.
6. Risoluzione Dei Problemi
This section addresses common issues you might encounter with your UPS. For more complex problems, contact customer support.
- UPS non si accende: Check if the AC input cable is securely connected and if the input circuit breaker has tripped. Ensure the battery is sufficiently charged.
- Durata breve della batteria: This may indicate aging batteries or an overloaded UPS. Reduce the connected load or consider battery replacement if the unit is old.
- Forte rumore della ventola: Some users have reported noticeable fan noise. While often normal for cooling, ensure the ventilation is not obstructed. If the noise is excessive or unusual, contact support.
- Connected Devices Not Receiving Power: Verify that the UPS is on and not in a fault state. Check the output receptacles and ensure devices are properly plugged in.
7. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Marca | Collegamento Pro |
| Numero di modello | PRO901-ES (USP-PRO901ES-3U) |
| Capacità | 1000VA/900W |
| Composizione delle celle della batteria | Piombo acido |
| Voltage | 240V |
| Volume di uscitatage | 240 Volt (CA) |
| Amprabbia | 7 Amps |
| Fattore di forma | Torre |
| Potenza Tipo spina | Tipo G |
| Tipo di connettore | Interfaccia USB, RS-232 |
| Numero di prese | 3 (Universal sockets) |
| Materiale di recinzione | Metallo |
| Colore | Nero |
| Specifica Met | EN 62040-2:2006, CE |
| Paese di origine | Cina |
8. Garanzia e supporto
The Prolink PRO901ES UPS comes with a Garanzia locale di 2 anno. For technical assistance or warranty claims, please refer to the contact information below.