This manual provides essential information for the safe and efficient operation, installation, and maintenance of your FibroPool 2 HP Swimming Pool Pump (Model FP200). Please read this manual thoroughly before installation and operation to ensure proper use and to prevent damage or injury.

The FibroPool FP200 is a high-efficiency single-speed motor pump designed for in-ground pools and spas. It features a durable, corrosion-proof construction and is engineered for reliable performance.

Informazioni sulla sicurezza

Always observe basic safety precautions when installing and operating this electrical equipment. Failure to follow instructions can result in serious injury or death.

  • Ensure the pump is connected to a 240-volt, 60 Hz power supply only. It is not convertible to 120 volts.
  • L'installazione deve essere eseguita da un professionista qualificato e deve essere conforme a tutte le normative elettriche e idrauliche locali e nazionali.
  • Scollegare sempre l'alimentazione dalla pompa prima di eseguire qualsiasi intervento di assistenza o manutenzione.
  • Non far funzionare la pompa a secco. Assicurarsi che la pompa sia caricata con acqua prima di avviarla.
  • Tenere i bambini lontani dalla pompa e dall'area delle attrezzature della piscina.
  • Do not operate the pump if any parts are damaged or missing.

Prodotto finitoview

The FibroPool FP200 pump is engineered for optimal performance and longevity. Key features include:

  • 2 horsepower motor, pushing up to 8100 GPH at 3450 RPM.
  • High-efficiency single-speed motor designed to reduce energy consumption.
  • Durable, weatherproof chassis suitable for various environments.
  • Integrated pedestal base for stable mounting.
  • Super-sized 124 cubic-inch strainer basket with a clear twist-lock lid for easy inspection and cleaning.
  • 2-inch unions included for simplified installation and servicing.
FibroPool FP200 Swimming Pool Pump, side view

Figura 1: lato view of the FibroPool FP200 Swimming Pool Pump, showing the motor and pump housing.

FibroPool FP200 Swimming Pool Pump, opposite side view

Figura 2: Lato opposto view of the FibroPool FP200 Swimming Pool Pump, highlighting the clear strainer lid.

Installazione

Proper installation is crucial for the pump's performance and longevity. It is recommended that installation be performed by a certified pool technician or electrician.

Selezione del sito

  • Installare la pompa il più vicino possibile alla piscina per ridurre al minimo la perdita di carico dovuta all'attrito delle tubature.
  • Assicurarsi che il luogo sia ben ventilato e protetto dalla luce solare diretta e dall'umidità eccessiva.
  • Provide adequate space around the pump for routine maintenance and servicing.
  • Mount the pump on a solid, level base to prevent vibration and noise. The integrated pedestal base provides stability.

Collegamenti idraulici

  • The pump is equipped with 2-inch unions for easy connection to your existing plumbing system.
  • Utilizzare cemento e primer per PVC appropriati per collegamenti sicuri e senza perdite.
  • Ensure all plumbing is properly supported to avoid strain on the pump.

Collegamenti elettrici

AVVERTIMENTO: Electrical wiring should only be performed by a licensed electrician.

  • The FibroPool FP200 operates on 240 volts, 60 Hz. Verify your power supply matches these requirements.
  • Connect the pump to a dedicated circuit protected by a Ground Fault Circuit Interrupter (GFCI).
  • The pump includes a 6-foot weatherproof power cable. Ensure all connections are secure and weatherproof.
  • Refer to local electrical codes for specific wiring requirements.
FibroPool FP200 Swimming Pool Pump, back view con cablaggio

Figura 3: Indietro view of the FibroPool FP200 pump, showing the electrical connection box and wiring.

Istruzioni per l'uso

Innesco della pompa

Before starting the pump for the first time, or after draining for maintenance, the pump must be primed.

  1. Ensure all valves are open to allow water flow from the pool to the pump.
  2. Remove the clear twist-lock lid from the strainer basket.
  3. Fill the strainer basket with water until it overflows.
  4. Replace the lid, ensuring it is securely twisted and sealed.
  5. Turn on the pump. The pump should prime within a few minutes. If not, turn off the pump, re-prime, and check for air leaks in the suction line.

Funzionamento normale

  • Once primed, the pump will circulate water through your pool system.
  • Monitor the pressure gauge on your filter system to ensure it is within the normal operating range.
  • The clear top lid allows for easy visual inspection of the strainer basket to determine when cleaning is needed.

Manutenzione

Regular maintenance ensures the longevity and efficient operation of your FibroPool pump.

Pulizia del cestello del filtro

The super-sized 124 cubic-inch basket has extra leaf-holding capacity, extending time between cleanings. However, regular inspection is recommended.

  1. Spegnere la pompa e scollegare l'alimentazione.
  2. Twist and remove the clear lid from the strainer housing.
  3. Rimuovere il cestello e svuotarlo da eventuali detriti.
  4. Sciacquare accuratamente il cestello con acqua.
  5. Controllare che l'O-ring sul coperchio non presenti crepe o segni di usura. Sostituirlo se necessario.
  6. Return the basket to the housing, ensuring it is seated correctly.
  7. Replace the lid, twisting it securely to create a watertight seal.
  8. Se necessario, riaprire la pompa prima di riavviarla.

svernamento

In areas subject to freezing temperatures, proper winterization is essential to prevent damage.

  • Scaricare tutta l'acqua dalla pompa rimuovendo i tappi di scarico.
  • Store the pump in a dry, protected area if possible.
  • Consult a pool professional for comprehensive winterization procedures for your entire pool system.

Risoluzione dei problemi

This section provides solutions to common issues you may encounter with your FibroPool pump.

ProblemaPossibile causaSoluzione
La pompa non si avviaNo power, tripped breaker/GFCI, faulty wiring, motor issue.Check power supply, reset breaker/GFCI. Verify electrical connections. If motor hums but doesn't start, contact a qualified technician.
La pompa funziona ma non si adesca o ha un flusso bassoAir leak in suction line, clogged strainer basket, low water level in pool, closed valves, impeller obstruction.Check and seal all suction line connections. Clean strainer basket. Ensure adequate pool water level. Open all necessary valves. Inspect impeller for debris.
Rumore o vibrazioni eccessiviAir leak, cavitation, loose mounting, worn bearings.Check for air leaks. Ensure pump is properly primed. Tighten mounting bolts. If noise persists, motor bearings may be worn; contact service.
Perdita d'acqua dalla pompaLoose plumbing connections, worn shaft seal, damaged O-rings.Tighten plumbing connections. Inspect and replace O-rings on strainer lid and unions. A leaking shaft seal requires professional service.

Specifiche

Detailed technical specifications for the FibroPool 2 HP Swimming Pool Pump FP200.

AttributoValore
MarcaFibropiscina
Numero di modelloFP200
Potenza2 CV
Voltage240 Volt
FrequenzaFrequenza 60 Hz
Cosatage1.5 kW
Portata massima135 galloni al minuto (8100 GPH)
giri al minuto3450 giri al minuto
MaterialeAluminum (Motor), Heavy Duty Plastic (Housing)
Peso dell'articolo34.9 libbre
Dimensioni del pacco25 x 14.5 x 11.5 pollici
Livello sonoro45 dB
Codice UPC850013473021
Performance curve chart for FibroPool pumps, showing Head vs Flow for FP100, FP150, FP200, and FP300 models.

Figure 4: Performance Curve Chart. The FP200 curve illustrates the relationship between pump head (pressure) and flow rate.

Garanzia e supporto

For warranty information, technical support, or service inquiries, please contact FibroPool directly. Keep your purchase receipt as proof of purchase.

While specific warranty details are not provided in this manual, FibroPool is committed to providing quality products and customer satisfaction. For the most current warranty terms and conditions, please visit the official FibroPool websito o contattare il loro servizio clienti.

You can often find contact information on the product packaging, the manufacturer's websito o tramite il rivenditore presso cui è stato acquistato il prodotto.

© 2024 FibroPool. All rights reserved.

Per maggiori informazioni, visita the FibroPool Store on Amazon.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.