AMX NX-3200

AMX NX-3200 NetLinx NX Integrated Controller User Manual

Modello: NX-3200

1. Introduzione

The AMX NX-3200 NetLinx NX Integrated Controller is designed for advanced control and automation in various environments, including large lecture halls, boardrooms, media rooms, and integrated homes. It offers robust security features, such as NX Master Security firmware and Dual NIC, to ensure secure communication over computer networks, meeting IT industry security standards. This manual provides essential information for the proper setup, operation, maintenance, and troubleshooting of your NX-3200 controller.

AMX NX-3200 NetLinx NX Integrated Controller, three-quarter rear view

Figure 1: AMX NX-3200 NetLinx NX Integrated Controller, showing the rear panel and side view.

2. Informazioni sulla sicurezza

Before operating the AMX NX-3200, read and understand all safety instructions. Retain this manual for future reference.

  • Assicurarsi che il dispositivo sia installato in un'area ben ventilata per evitare il surriscaldamento.
  • Only use the power supply provided or specified by AMX.
  • Non esporre il dispositivo a umidità, pioggia o temperature estreme.
  • Evitare di posizionare oggetti pesanti sul dispositivo.
  • Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato. Non tentare di aprire o riparare l'unità da soli.

3. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

  • AMX NX-3200 NetLinx NX Integrated Controller
  • Alimentazione (12 V CC)
  • Hardware di montaggio (se applicabile)
  • Documentazione (questo manuale, guida rapida)

4. Prodotto finitoview

4.1 Pannello frontale

AMX NX-3200 NetLinx NX Integrated Controller front panel

Figure 2: Front Panel of the AMX NX-3200.

The front panel of the NX-3200 provides status indicators and a TO PC port for direct connection. Key components include:

  • TO PC (USB) Port: For direct connection to a computer for initial configuration and firmware updates.
  • LINK/ACT LED: Indicates network link status and activity.
  • LED DI STATO: Displays the operational status of the controller.
  • LED DI USCITA: Indicates output activity.
  • LED INGRESSO: Indicates input activity.
  • ICS LAN LED: Status indicator for the ICS LAN connection.
  • SERIAL (TX/RX) LEDs: Indicators for transmit and receive activity on serial ports 1-8.
  • RELAYS LEDs: Status indicators for relay outputs 1-8.
  • IR/SERIAL LEDs: Indicators for IR/Serial ports 1-8.
  • I/O LEDs: Status indicators for I/O ports 1-8.

4.2 Pannello posteriore

AMX NX-3200 NetLinx NX Integrated Controller rear panel

Figure 3: Rear Panel of the AMX NX-3200.

The rear panel provides all necessary connections for integrating the NX-3200 into your system. These include:

  • RS-232 Ports (1-8): For serial communication with various devices.
  • RS-232/422/485 Ports (1-8): Configurable serial ports for flexible communication.
  • Relay Ports (1-8): For controlling external devices requiring contact closure.
  • I/O Ports (1-8): General purpose input/output ports.
  • IR/Serial Ports (1-8): For infrared control or additional serial communication.
  • ICS LAN Port: Ethernet port for network connectivity and control.
  • LAN 10/100 Port: Additional Ethernet port for network connectivity, supporting Dual NIC functionality.
  • USB Ports (Type A and B): For connecting USB devices or for direct PC connection.
  • PWR (12VDC) Input: Connettore di ingresso alimentazione.
  • CONFIG Button: For system configuration and reset functions.

5. Impostazione

5.1 Montaggio del controller

The NX-3200 is designed for rack mounting or placement on a flat surface. Ensure adequate ventilation around the unit.

  • For rack mounting, secure the controller using appropriate rack ears and screws (sold separately or included in package).
  • When placing on a surface, ensure it is stable and free from obstructions to airflow.

5.2 Collegamento dell'alimentazione

  1. Connect the provided 12VDC power supply to the PWR input on the rear panel.
  2. Collegare l'alimentatore a una presa elettrica adatta.
  3. The controller will power on automatically. Observe the STATUS LED on the front panel.

5.3 Connessioni di rete

The NX-3200 features Dual NIC for enhanced network security and flexibility.

  • ICS LAN: Connect an Ethernet cable from your network switch or router to the ICS LAN port for control network communication.
  • LAN 10/100: Connect an Ethernet cable to the LAN 10/100 port for a secondary network connection, if required for specific applications or network segmentation.

5.4 Collegamento dei dispositivi di controllo

Connect your AV equipment, HVAC systems, lighting, and other devices to the appropriate ports on the rear panel.

  • Dispositivi seriali: Use RS-232, RS-422, or RS-485 ports as needed. Refer to the device's documentation for wiring requirements.
  • Relay Devices: Connect devices requiring contact closure to the Relay ports.
  • I/O Devices: Connect sensors or other input/output devices to the I/O ports.
  • Emettitori IR: Connect IR emitters to the IR/Serial ports for controlling IR-controlled equipment.

5.5 Configurazione iniziale

Initial configuration is typically performed using AMX programming software via the TO PC USB port or over the network.

  1. Connect a computer to the TO PC USB port on the front panel using a standard USB cable.
  2. Install the necessary AMX software (e.g., NetLinx Studio) on your computer.
  3. Follow the software instructions to discover the controller and upload your control program.
  4. Alternatively, if the controller has a default IP address or is configured for DHCP, it can be accessed over the network.

6. Funzionamento del controller

6.1 Comprensione degli indicatori LED

The front panel LEDs provide visual feedback on the controller's status and activity:

  • LED DI STATO:
    • Verde pieno: Funzionamento normale.
    • Verde lampeggiante: Booting up or performing a task.
    • Rosso pieno: Error or fault condition.
  • LINK/ACT LED:
    • Verde pieno: Network link established.
    • Verde lampeggiante: Attività di rete.
  • Other TX/RX, RELAYS, IR/SERIAL, and I/O LEDs illuminate to indicate data transmission, reception, or active states on their respective ports.

6.2 Funzionamento di base

Once configured and programmed, the NX-3200 operates autonomously based on the loaded control program. User interaction typically occurs through connected control interfaces (e.g., touch panels, keypads, web interfaces) that communicate with the controller.

  • Ensure all controlled devices are powered on and connected correctly.
  • Use your programmed control interface to send commands to the NX-3200, which then executes the corresponding actions (e.g., turning on a projector, adjusting volume, closing blinds).

6.3 Comunicazione sicura

The NX-3200 supports NX Master Security firmware for secure communication. Ensure your network infrastructure and programming leverage these features for enhanced data protection, especially in enterprise and government environments.

7. Manutenzione

7.1 Pulizia

  • Scollegare l'alimentazione prima della pulizia.
  • Utilizzare un panno morbido e asciutto per pulire l'esterno dell'unità.
  • Non utilizzare detergenti liquidi o spray aerosol, poiché potrebbero danneggiare l'unità.
  • Assicurarsi che le aperture di ventilazione siano libere da polvere e detriti.

7.2 Aggiornamenti firmware

Periodically check the AMX website for firmware updates. Keeping your controller's firmware up-to-date ensures optimal performance, security, and access to new features.

  1. Download the latest firmware from the official AMX support portal.
  2. Follow the instructions provided with the firmware update package for installation, typically using AMX programming software.

8. Risoluzione Dei Problemi

If you encounter issues with your NX-3200, refer to the following common problems and solutions:

Problema Possibile causa Soluzione
Il controller non si accende. Nessuna alimentazione, alimentatore difettoso o collegamento allentato.
  • Verify power cable is securely connected to the unit and outlet.
  • Assicurarsi che la presa sia funzionante.
  • Test with a known good power supply if available.
STATUS LED is solid red. Errore o guasto del sistema.
  • Eseguire un ciclo di accensione/spegnimento (scollegare, attendere 10 secondi, ricollegare).
  • If the issue persists, contact AMX technical support.
Nessuna connettività di rete. Incorrect cable, network configuration issue, or switch problem.
  • Check Ethernet cables for secure connection and damage.
  • Verify network settings (IP address, subnet mask, gateway) are correct.
  • Ensure the network switch port is active.
  • Check LINK/ACT LED on the front panel.
Controlled device not responding. Incorrect wiring, incorrect programming, or device fault.
  • Verify physical connections to the NX-3200 ports.
  • Confirm the control program is correctly configured for the device.
  • Test the controlled device independently to ensure it is functional.
  • Check relevant TX/RX, RELAYS, IR/SERIAL, or I/O LEDs for activity.

8.1 Ripristino delle impostazioni di fabbrica

A factory reset will erase all custom configurations and programming, restoring the controller to its default settings. Use this as a last resort.

  1. Disconnect power from the NX-3200.
  2. Premere e tenere premuto il tasto CONFIG pulsante sul pannello posteriore.
  3. While holding the CONFIG button, reconnect power.
  4. Continue holding the CONFIG button until the STATUS LED changes color or flashes in a specific pattern (refer to AMX documentation for exact sequence), then release.
  5. The controller will reboot with factory default settings.

9. Specifiche

Technical specifications for the AMX NX-3200 NetLinx NX Integrated Controller:

Caratteristica Dettaglio
Numero di modello NX-3200
Dimensioni del prodotto 9.1 x 17 x 1.8 pollici
Peso dell'articolo 6.08 libbre
Potenza in ingresso 12VDC (via external power supply)
Porte seriali 8x RS-232, 8x RS-232/422/485 (configurable)
Porte relè 8x (contact closure)
Porte I/O 8x (general purpose)
IR/Serial Ports 8x
Porte Ethernet 1x ICS LAN, 1x LAN 10/100 (Dual NIC)
Porte USB Type A, Type B (TO PC)
Firmware NX Master Security firmware
Produttore Harman International Industries, Inc

10. Garanzia e supporto

For warranty information and technical support, please refer to the official AMX website or contact your authorized AMX dealer.

  • AMX Official Websito: www.amx.com
  • Supporto tecnico: Contact information can be found on the AMX websezione di supporto del sito.
  • Quando contatti l'assistenza, tieni a portata di mano la ricevuta d'acquisto e il numero di serie del prodotto.

© 2024 AMX. All rights reserved. Information in this document is subject to change without notice.

Ask a question about this manual