Walfront Walfrontm160hrd9ey6020-12

STVP-936 LCD Adjustable Voltage Manuale dell'utente di Protector

Comprehensive guide for the installation, operation, and maintenance of your Walfront STVP-936 Three-Phase LCD Multifunctional Self-Resetting Voltage Protettore.

1. Prodotto finitoview

The Walfront STVP-936 is a sophisticated three-phase four-wire automatic reset over-voltage, sotto-volumetage, and multi-function protector. Designed for power systems and electrical equipment, it provides comprehensive protection against various electrical anomalies, ensuring the safety and longevity of connected devices. It integrates over-voltage, sotto-volumetage, sovracorrente, vol trifasetage unbalance, phase sequence (phase dislocation), and phase-break protection into a single unit.

Walfront STVP-936 LCD Adjustable Voltage Protector front view

Figura 1: Fronte view of the STVP-936 LCD Adjustable Voltage Protector, showing the LCD display and control buttons.

Caratteristiche principali:

  • Ripristino automatico: Ripristina automaticamente l'alimentazione quando il volumetage returns to normal after an anomaly.
  • Protezione multifunzionale: Combines over-voltage, sotto-volumetage, over-current, three-phase unbalance, phase sequence, and phase-break protection.
  • Schermo LCD: Clear display for real-time voltage and current readings, and easy parameter adjustment.
  • Richiesta di guasti: Allows users to check fault history.
  • Parametri regolabili: Customizable protection values and recovery times.

2. Configurazione e installazione

2.1 Precauzioni di sicurezza

  • Prima dell'installazione o della manutenzione, assicurarsi che tutta l'alimentazione sia scollegata.
  • L'installazione deve essere eseguita da un elettricista qualificato.
  • Verify correct wiring according to the provided diagrams and local electrical codes.
  • Non utilizzare il dispositivo se appare danneggiato.

2.2 Istruzioni di montaggio

The STVP-936 is designed for rail vertical installation. Ensure adequate space for ventilation and wiring connections. Mount the device securely on a standard DIN rail within an electrical enclosure.

Dimensions of the STVP-936 Voltage Protettore

Figure 2: Dimensions of the STVP-936, indicating its compact size for rail mounting.

2.3 Schema elettrico

The device is suitable for three-phase four-wire power systems (230V/400VAC 50/60Hz). Connect the incoming power lines (L1, L2, L3, N) to the "IN" terminals and the outgoing load lines to the "OUT" terminals. Refer to the diagram printed on the device for specific terminal identification (N, L1, L2, L3).

Lato view of STVP-936 showing input and output terminals

Figura 3: lato view illustrating the input (IN) and output (OUT) terminals for wiring connections.

3. Guida operativa

Display LCD 3.1

The LCD screen provides real-time monitoring of voltage and current. It also displays fault codes and allows for parameter configuration.

Close-up of STVP-936 LCD display and control buttons

Figura 4: dettagliata view of the LCD display and the 'SET', 'Up', and 'Down' buttons for navigation and adjustment.

3.2 Impostazione dei parametri

Utilizzare il IMPOSTATO per accedere alla modalità di impostazione dei parametri. Utilizzare il pulsante Up () E Giù () buttons to adjust values. Press IMPOSTATO again to confirm and move to the next parameter. The device will automatically save settings after a short period of inactivity in setting mode.

Parametri regolabili:

  • Valutazione attuale: 1-63A adjustable (default 63A).
  • Sovravoltage Protection Value (Uvo): 221V-300V-OFF (default 280V).
  • Sovravoltage Valore di recupero: 220V-299V (default 250V).
  • Sovravoltage Tempo di azione di protezione: 0.1-10 seconds (default 0.2 seconds).
  • Sottovoltage Protection Value (Uve): 219V-150V-OFF (default 160V).
  • Sottovoltage Valore di recupero: 220V-151V (default 180V).
  • Sottovoltage Tempo di azione di protezione: 0.1-10 seconds (default 0.2 seconds).
  • Overcurrent Protection Action Time: 1-512 seconds (default 5 seconds).
  • Vol. trifasetage Unbalance Protection Value: 5%-90%-OFF (default 25%).
  • Fase Voltage Unbalance Protection Action Time: 0.1-10 seconds (default 2.0 seconds).
  • Power-On Delay Time: 2-255 seconds (default 2 seconds).
  • Failure Recovery Delay Time: 2-512 seconds (default 60 seconds).

3.3 Ripristino delle impostazioni di fabbrica

The device has a function to restore factory default settings. Refer to the specific instructions in the full product manual or contact support for the exact procedure.

4. Manutenzione

The STVP-936 is designed for minimal maintenance. However, periodic checks are recommended to ensure optimal performance and safety:

  • Pulizia: Mantenere il dispositivo pulito e privo di polvere. Utilizzare un panno asciutto e morbido per la pulizia. Non utilizzare detergenti liquidi.
  • Verifica della connessione: Controllare periodicamente i collegamenti elettrici per assicurarsi che siano saldi e privi di corrosione.
  • Condizioni ambientali: Assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.

5. Risoluzione Dei Problemi

If the device is not functioning as expected, consider the following common issues:

  • Nessuna alimentazione/Display spento: Check incoming power supply and wiring connections. Ensure the device is correctly installed.
  • Frequenti inciampi: Review the set protection parameters (overvoltage, sottovoltage, overcurrent) to ensure they are appropriate for your electrical system. Check for actual power fluctuations or overloads.
  • Letture errate: Verify wiring. If readings are consistently inaccurate, the device may require professional inspection.
  • Device Not Resetting: Check the failure recovery delay time setting. Ensure the fault condition has cleared.

The device also features a fault inquiry function. Consult the full product manual for details on how to access and interpret fault codes.

6. Specifiche tecniche

Parametro Valore
Volume nominaletage (Three-Phase Four-Wire) 230 V/400 V CA 50/60 Hz
Current Rating (Adjustable) 1-63A (predefinito 63A)
Sovravoltage Intervallo di valori di protezione 221V-300V-OFF (default 280V)
Sovravoltage Recovery Value Range 220 V-299 V (predefinito 250 V)
Sovravoltage Tempo di azione di protezione 0.1-10 secondi (predefinito 0.2 secondi)
Sottovoltage Intervallo di valori di protezione 219V-150V-OFF (default 160V)
Sottovoltage Recovery Value Range 220 V-151 V (predefinito 180 V)
Sottovoltage Tempo di azione di protezione 0.1-10 secondi (predefinito 0.2 secondi)
Overcurrent Protection Action Time 1-512 secondi (predefinito 5 secondi)
Vol. trifasetage Unbalance Protection Value 5%-90%-OFF (default 25%)
Fase Voltage Unbalance Protection Action Time 0.1-10 secondi (predefinito 2.0 secondi)
Power-On Delay Time 2-255 secondi (predefinito 2 secondi)
Failure Recovery Delay Time 2-512 secondi (predefinito 60 secondi)
Consumo energetico ≤3VA
Modalità di visualizzazione LCD
Metodo di installazione Rail vertical installation
Temperatura dell'ambiente di lavoro -20℃~50℃
Umidità dell'ambiente di lavoro <85%
Altitudine Non più di 2000 metri
Dimensioni (circa) 70 x 95mm (2.8 x 3.7in), 65mm (2.6in), 43mm (1.7in), 45mm (1.8in), 35mm (1.4in)
Peso dell'articolo 13.5 once

7. Garanzia e supporto

7.1 Informazioni sulla garanzia

Please refer to the manufacturer's official warranty policy for details regarding coverage, terms, and conditions. Typically, electronic devices come with a limited warranty against manufacturing defects.

7.2 Assistenza clienti

For technical assistance, troubleshooting, or warranty claims, please contact Walfront customer support. You can find more information and contact details by visiting the official Walfront store page:

Visit the Walfront Store on Amazon

© 2024 Walfront. All rights reserved. This manual is for informational purposes only.