OWON SDS1102

OWON SDS1102 Digital Oscilloscope User Manual

Model: SDS1102 | Brand: OWON

1. Introduzione

The OWON SDS1102 is a 2-channel digital storage oscilloscope designed for a wide range of electronic measurement and analysis tasks. It features a 100 MHz bandwidth, a 1 GSa/s real-time sampling rate, and a clear 7-inch TFT-LCD display. This manual provides essential information for setting up, operating, maintaining, and troubleshooting your device, ensuring optimal performance and longevity.

OWON SDS1102 Digital Oscilloscope front view with screen displaying waveforms and control panel.

Figure 1: OWON SDS1102 Digital Oscilloscope

2. Informazioni sulla sicurezza

Please read and understand all safety instructions before operating the device. Failure to comply with these instructions may result in electric shock, fire, or damage to the product.

  • Utilizzare esclusivamente il cavo di alimentazione fornito con il dispositivo.
  • Assicurarsi che il dispositivo sia correttamente collegato a terra per evitare scosse elettriche.
  • Non utilizzare il dispositivo in ambienti bagnati o damp condizioni.
  • Evitare di esporre il dispositivo alla luce solare diretta o a temperature elevate.
  • Non aprire il dispositivo casing; affidare ogni intervento di manutenzione a personale qualificato.
  • Verify probe attenuation settings match the oscilloscope's input settings.

3. Contenuto della confezione

Verifica che tutti gli articoli elencati di seguito siano inclusi nel tuo pacchetto:

  • OWON SDS1102 Digital Oscilloscope
  • Cavo di alimentazione
  • CD-ROM (contenente software e documentazione)
  • Cavo USB
  • Sonde per oscilloscopio (2 unità)
  • Strumento di regolazione della sonda (cacciavite)
  • Manuale dell'utente (questo documento)

4. Prodotto finitoview

The SDS1102 is designed for efficiency and accuracy in various applications, from electronic circuit debugging to automotive maintenance.

Caratteristiche principali:

  • Schermo LCD HD: A 7-inch color TFT-LCD with 65535 colors and 800 x 480 pixel resolution provides clear and concise waveform readings. It supports four automatic cursor modes for precise voltage misurazioni della differenza di tempo.
  • Alta Samptasso di ling: Equipped with a 1 GSa/s sampling rate, the device allows for detailed waveform capture and analysis. It includes single waveform recording and playback, and supports plug-and-play USB storage devices.
  • Powerful System: Features an auto-range function and supports horizontal, vertical, single/multi-waveform tracking. Probe attenuation settings include 1x, 10x, 100x, and 1000x. It offers 30 types of automatic measurement functions and supports LABVIEW communication for secondary development.
  • Portabilità: With ultra-thin body design (301 x 152 x 70 mm) and a weight of 1.1 kg, the oscilloscope is highly portable, saving desktop space and operating quietly.
OWON SDS1102 Oscilloscope highlighting 1GS/s Sample rate, 2-Channel, 10K Record Length, 100 MHz Bandwidth, and 7 inch high resolution LCD.

Figure 2: Key features of the SDS1102 Oscilloscope

Diagram showing the dimensions (301x152x70mm) and weight (1.1 kg) of the ultra-thin OWON SDS1102 Oscilloscope.

Figure 3: Compact design and dimensions for portability

Four images depicting various applications of the oscilloscope: circuit testing, design and manufacture, education and training, and automobile maintenance.

Figure 4: Diverse applications of the SDS1102 Oscilloscope

5. Impostazione

5.1 Accensione iniziale

  1. Connect the power cord to the oscilloscope and a suitable power outlet.
  2. Premere il pulsante di accensione per accendere il dispositivo.
  3. The 7-inch TFT-LCD display will illuminate, showing the OWON logo and then the main waveform interface.

5.2 Calibrazione della sonda

Before taking measurements, it is crucial to calibrate the oscilloscope probes for accurate readings. This process compensates for any slight variations in the probes as supplied.

  1. Connect a probe to one of the BNC input connectors (e.g., CH1).
  2. Ensure the probe's attenuation switch (usually on the probe body) is set to 10x.
  3. Connect the probe tip to the test point, which is a small metal loop located on the bottom right of the oscilloscope's front panel.
  4. Attach the black grounding alligator clip of the probe to the lower metal loop, which serves as the ground test point.
  5. Premere il tasto Impostazione automatica button on the oscilloscope. The device will automatically adjust settings to display the test signal. The test point outputs a 1 kHz, 5V square wave.
  6. Observe the waveform on the screen. If it does not appear as a perfect square wave (e.g., rounded corners or overshoot), use the supplied probe adjustment tool (small screwdriver).
  7. Carefully insert the screwdriver into the compensation screw on the BNC connector of the probe and adjust it until the displayed square wave is clean and flat on top and bottom, with sharp corners. A slight turn (approximately 1/8th) may be sufficient.
  8. Repeat this process for all probes you intend to use.
A hand using an oscilloscope probe to test a circuit board, with the OWON SDS1102 Oscilloscope in the background.

Figure 5: Oscilloscope probe connected to a circuit for testing

6. Istruzioni per l'uso

6.1 Visualizzazione della forma d'onda di base

  • Collegare la sonda al circuito in prova.
  • Regolare il Vertical Scale (VOLTS/DIV) E Horizontal Scale (SEC/DIV) knobs to get a stable and viewable waveform on the screen.
  • Utilizzare il Posizione manopole per spostare la forma d'onda verticalmente o orizzontalmente.
  • Premere il tasto Impostazione automatica pulsante per l'ottimizzazione automatica della forma d'onda.
Oscilloscope screen demonstrating the auto-range function, adjusting the display to fit the input signal.

Figure 6: Auto-range function in action

6.2 Misurazioni del cursore

The SDS1102 supports four automatic cursor modes for precise measurements.

  1. Premere il tasto Cursore pulsante.
  2. Selezionare il tipo di cursore desiderato (ad esempio, Voltage, Time) using the menu options.
  3. Adjust the cursor positions using the multipurpose knob to measure specific points on the waveform.
  4. The measured values (e.g., ◊V, ◊T) will be displayed on the screen.
Oscilloscope screen displaying a waveform with cursor measurements for voltage e differenze di fuso orario.

Figure 7: Performing cursor measurements

6.3 Misurazioni automatiche

The oscilloscope offers 30 types of automatic measurements for quick analysis.

  1. Premere il tasto Misura pulsante.
  2. Navigate through the menu to select the desired automatic measurements (e.g., Frequency, Peak-to-Peak Voltage, RMS).
  3. The selected measurements will be displayed on the screen, updating in real-time.
Oscilloscope screen displaying a comprehensive list of automatic measurements for a waveform, including Min, Max, Peak-to-Peak, Frequency, Period, and more.

Figure 8: Automatic measurement display

6.4 Waveform Recording and Playback

The device allows for recording and replaying single waveforms.

  1. Premere il tasto Salva/Richiama button (or similar function).
  2. Select the option to record a waveform.
  3. To replay, select the playback option and choose the desired stored waveform.
Oscilloscope screen showing a menu for saving and recalling waveforms, demonstrating the waveform recording and playback function.

Figure 9: Waveform save and recall menu

6.5 USB Connectivity and PC Control

The SDS1102 supports plug-and-play USB storage devices for saving data and configurations. It also allows for remote communication and control via a computer using the USB interface, with support for LABVIEW and SCPI commands.

OWON SDS1102 Oscilloscope connected via USB cable to a laptop, demonstrating SCPI and LabVIEW support for remote control.

Figure 10: USB connection for PC communication and data transfer

7. Manutenzione

The OWON SDS1102 is designed for continuous, maintenance-free use under normal operating conditions. However, proper care ensures its longevity and performance.

  • Pulizia: Utilizzare un panno morbido e asciutto per pulire l'esterno dell'oscilloscopio. Per lo sporco ostinato, utilizzare un panno leggermenteamp È possibile utilizzare un panno imbevuto di detergente delicato, assicurandosi che non penetri liquido nel dispositivo. Non utilizzare detergenti abrasivi o solventi.
  • Magazzinaggio: When not in use, store the oscilloscope in a clean, dry environment, away from extreme temperatures and humidity.
  • Cura della sonda: Maneggiare le sonde con cura. Evitare di piegare o sollecitare i cavi. Mantenere pulite le punte delle sonde.
  • Manutenzione interna: The device does not require user-performed internal maintenance. Do not attempt to open the casing, poiché ciò potrebbe invalidare la garanzia ed esporvi a rischi elettrici.

8. Risoluzione Dei Problemi

If you encounter issues with your OWON SDS1102, refer to the following common troubleshooting steps:

Problema Possibile causa Soluzione
Il dispositivo non si accende. Power cord not connected; power outlet faulty; device fault. Check power cord connection. Test power outlet with another device. If problem persists, contact support.
Nessuna forma d'onda visualizzata. Probe not connected; probe faulty; input signal too small/large; incorrect vertical/horizontal settings. Ensure probes are securely connected. Check probe functionality. Adjust VOLTS/DIV and SEC/DIV. Use Autoset.
Waveform is distorted or noisy. Uncalibrated probe; poor grounding; external interference. Perform probe calibration (Section 5.2). Ensure proper grounding. Minimize external electromagnetic interference.
USB storage not recognized. USB device format incompatible; faulty USB device/port. Ensure USB device is formatted correctly (e.g., FAT32). Try a different USB device or port.

For issues not covered here, please refer to the full manual on the provided CD-ROM or contact OWON customer support.

9. Specifiche

Caratteristica Specificazione
Produttore Ovunque
Numero di modello OWON-SDS1102
Dimensioni (L x P x A) Dimensioni: 30.1 x 15.2 x 7 cm
Peso 1.67 kg
Display 7-inch Color TFT-LCD, 800 x 480 pixels
Canali 2
Larghezza di banda 100 MHz
Sampla tariffa 1 GSa/s
Lunghezza del record 10K punti
Ora di alzarsi ≤1.7 ns
Attenuazione della sonda 1x, 10x, 100x, 1000x
Misurazioni automatiche 30 tipi
Connettività USB (for storage, PC communication)
Supporto software LABORATORIOVIEW, SCPI
Batterie incluse NO
Data prima disponibilità 23 giugno 2022
Banner displaying key specifications: 100MHz, 7 inch LCD, 2-Channel, 1GS/s, Record length 10K, less than or equal to 1.7ns Rise time.

Figure 11: Summary of key technical specifications

10. Garanzia e supporto

OWON products are designed for reliability and performance. For warranty information, please refer to the documentation included on the CD-ROM or visit the official OWON website. Information regarding the availability of spare parts is currently unavailable.

For technical support, product inquiries, or service requests, please contact OWON customer service through their official channels. Keep your purchase receipt and product model number (OWON-SDS1102) handy when contacting support.

Ask a question about this manual