1. Prodotto finitoview
The Rinnai REP199iN Smart-Circ Non-Condensing Natural Gas Tankless Water Heater is designed for indoor installation, providing on-demand hot water with a built-in recirculation pump. This model features Smart-Circ technology, which learns your household's hot water usage patterns to optimize recirculation, reducing wait times and conserving energy. Its compact design allows for installation in various spaces, offering a continuous supply of hot water for residential use.

Figura 1: Fronte view of the Rinnai REP199iN Tankless Water Heater.
2. Informazioni sulla sicurezza
AVVERTENZA: installazione, regolazione, alterazione, assistenza o manutenzione non corrette possono causare danni materiali, lesioni o morte. Leggere attentamente le istruzioni di installazione, funzionamento e manutenzione prima di installare o sottoporre a manutenzione questa apparecchiatura.
- Questo apparecchio deve essere installato da un professionista qualificato in conformità con tutti i codici e le normative locali.
- Ensure adequate ventilation as specified in the installation manual.
- Non conservare o utilizzare benzina o altri vapori e liquidi infiammabili nelle vicinanze di questo o di altri apparecchi.
- Verify that the gas supply type (Natural Gas) matches the appliance requirements.
- Keep the area around the water heater clear of combustible materials.
3. Configurazione e installazione
Professional installation is strongly recommended for the Rinnai REP199iN water heater. Refer to the comprehensive installation manual provided with the unit for detailed instructions and diagrams. Key considerations include:
- Posizione: This model is designed for indoor installation. Ensure the chosen location meets clearance requirements and has proper ventilation. The compact size (14.05"W x 27.24"H) allows for flexible placement.
- Montaggio: The unit is wall-mounted. Ensure the mounting surface is structurally sound to support the unit's weight (approximately 24.04 kg).
- Collegamenti gas e acqua: Proper sizing and connection of natural gas and water lines are critical. Use appropriate fittings and ensure all connections are leak-free.
- Ventilazione/Scarico: An appropriate exhaust pipe system is required. Rinnai-specific exhaust components are recommended for optimal performance and safety. Plan for exhaust pipe installation before mounting the unit.
- Collegamento elettrico: L'unità richiede un'alimentazione elettrica da 120 Volt.

Figura 2: Esample of an indoor Rinnai tankless water heater installation.

Figura 3: Posteriore view of the Rinnai REP199iN unit, highlighting connection points.

Figura 4: lato view of the Rinnai REP199iN showing the digital display and controls.
4. Istruzioni per l'uso
The Rinnai REP199iN operates on an on-demand principle, heating water only when a hot water tap is opened. This ensures an endless supply of hot water without the need for a storage tank.
- Ricircolo intelligente Smart-Circ: The built-in recirculation pump, combined with Smart-Circ technology, learns your hot water usage patterns. It anticipates demand and circulates hot water proactively, reducing wait times at the tap.
- Controllo della temperatura: The unit's digital display allows for precise temperature setting, up to a maximum of 140 degrees Fahrenheit.
- Portata: This model provides up to 7.9 Gallons Per Minute (GPM), capable of supplying hot water to multiple fixtures simultaneously (e.g., up to 6 fixtures at once).
- WiFi Connectivity (Optional): The unit can be made smarter with a Rinnai Controlr module (not included) for WiFi control and remote monitoring.

Figure 5: Tankless water heater operation, heating water as it flows through the unit.

Figure 6: Illustration of the recirculation technology, ensuring hot water is readily available.
5. Manutenzione
Regular maintenance is essential to ensure the longevity and efficient operation of your Rinnai tankless water heater. Annual maintenance is recommended.
- Decalcificazione: Annually descale the unit to remove mineral buildup, especially in areas with hard water. This process typically involves circulating a descaling solution through the heat exchanger. Consult the full manual for detailed descaling procedures or contact a qualified technician.
- Ispezione della ventilazione: Periodically inspect the air intake and exhaust vents for any obstructions. Ensure they are clear of debris, insects, or other blockages.
- Pulizia del filtro dell'acqua: If your system includes an inline water filter, clean or replace it as recommended by the manufacturer to prevent sediment from entering the unit.
- Controlli delle perdite: Regularly inspect all water and gas connections for any signs of leaks. Address any leaks immediately.
6. Risoluzione Dei Problemi
If you encounter issues with your Rinnai REP199iN water heater, refer to the following general troubleshooting steps. For complex problems or error codes, contact a qualified service technician.
- Niente acqua calda: Check if the unit has power and if the gas supply valve is open. Ensure no error codes are displayed.
- Acqua calda insufficiente: Verify that the temperature setting is appropriate. Check for adequate water flow to the unit. Multiple simultaneous hot water demands might temporarily reduce temperature if the unit is undersized for peak usage.
- Codici di errore: If an error code appears on the digital display (e.g., Code 63), consult the detailed troubleshooting section in the full owner's manual for specific remedies. Many codes indicate issues that require professional attention.
- Bassa pressione dell'acqua: Check for closed shut-off valves, kinks in water lines, or clogged filters.
If troubleshooting steps do not resolve the issue, contact Rinnai customer support or a certified Rinnai technician.
7. Specifiche
| Caratteristica | Specificazione |
|---|---|
| Marca | Rinnai |
| Numero di modello | REU-VEP2737FFD-US-N |
| Fonte di alimentazione | Gas naturale |
| Potenza termica | 199,000 unità termiche britanniche (BTU) |
| Portata | 7.9 galloni al minuto (GPM) |
| Temperatura massima | 140 gradi Fahrenheit |
| Dimensioni del prodotto (L x A) | 14.05"L x 27.24"A |
| Peso dell'articolo | 24.04 chilogrammi |
| Voltage | 120 Volt |
| Tipo di materiale | Acciaio inossidabile |
| Tipo di montaggio | Parete |
| Efficienza | Alta efficienza |
| Componenti inclusi | Scaldabagno senza serbatoio |
8. Informazioni sulla garanzia
The Rinnai REP199iN Tankless Water Heater comes with a residential guarantee:
- Scambiatore di calore: Garanzia di 15 anno
- Parti: Garanzia di 5 anno
- Lavoro: Garanzia di 1 anno
Please refer to the official Rinnai warranty documentation for complete terms and conditions, including any exclusions or requirements for maintaining warranty coverage.
9. Supporto e risorse
For additional support, product guides, manuals, energy information, or to locate a qualified technician:
- Visita il sito ufficiale Rinnai websito.
- Utilize the "Find a Rinnai PRO" tool on the Rinnai website to locate a certified installer or service professional in your area.
- Contact Rinnai customer support directly for assistance with product inquiries or technical issues.
Video del prodotto
Caratteristiche e vantaggi
Questo video fornisce un overview of the key features and benefits of Rinnai tankless water heaters, including energy efficiency and continuous hot water supply.
Rinnai RE/REP 360 Tankless Video
Un breve giro a 360 gradi view of the Rinnai RE/REP series tankless water heater, showcasing its design and compact form factor.