IBO S-150 Central Heating Pump Controller User Manual

1. Prodotto finitoview

The IBO S-150 is an electronic control unit designed for managing the circulation pump in a central heating system. Its primary function is to activate the pump when the water temperature exceeds a preset value and deactivate it when the temperature falls below that value. This intelligent control helps to optimize energy consumption and extend the operational lifespan of the pump.

Caratteristiche principali:

  • Integrated Thermostat Function: Allows setting specific temperature thresholds for pump activation and deactivation.
  • Funzione antigelo: Automatically activates the pump if the ambient temperature drops below 5 °C (41 °F) to prevent freezing within the system.
  • Risparmio energetico: Prevents unnecessary pump operation, leading to reduced energy consumption.
  • Extended Pump Lifespan: Reduces wear and tear on the pump by operating it only when required.
  • Indicatori LED: Two LED displays show current temperature and set stop temperature.
  • Interfaccia intuitiva: Simple button controls for setting parameters.

2. Informazioni sulla sicurezza

Leggere attentamente tutte le istruzioni di sicurezza prima dell'installazione e dell'uso. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o lesioni gravi.

  • Sicurezza elettrica: Installation and maintenance should only be performed by qualified personnel in accordance with local electrical codes and regulations.
  • Disconnessione dell'alimentazione: Always disconnect the power supply to the central heating system and the controller before performing any installation, wiring, or maintenance.
  • Acqua e umidità: Do not expose the controller to water, excessive moisture, or extreme temperatures. Ensure the installation location is dry and protected.
  • Messa a terra corretta: Assicurarsi che il dispositivo sia correttamente collegato a terra per evitare rischi elettrici.
  • Integrità del cavo: Regularly inspect all cables for damage. Do not use the device if any cables are frayed or damaged.
  • Uso previsto: Use the controller only for its intended purpose as a central heating pump controller.

3. Specifiche tecniche

ParametroValore
Temperature Setting Range (Set Temperature)da 0 °C a 99 °C (da 32 °F a 210 °F)
Temperature Setting Range (Stop Temperature)da 0 °C a 99 °C (da 32 °F a 210 °F)
Temperatura ambienteda -10 °C a 40 °C (da 14 °F a 104 °F)
Tipo di sensore di temperaturaOhmico
Volume di alimentazionetage230 V, 50 Hz, ±10%
Power Consumption (Controller Only)<5W
Lunghezza del cavo del sensoreCirca 1 m (3.3 piedi)
Lunghezza del cavo di alimentazioneCirca 1 m (3.3 piedi)
Pump Power Cable LengthCirca 1 m (3.3 piedi)
Produzione230 V / Hz 50
Maximum Load (Pump)6 A (Resistive Load)
Precisione di misurazioneTemperatura ~0.1 °C
Dimensioni del prodotto (L x P x A)14 x 14 x 5 cm (5.5 x 5.5 x 2 pollici)
Peso370 grammi (0.82 libbre)

4. Installazione e configurazione

Before proceeding with installation, ensure the main power supply to your central heating system is turned off at the circuit breaker.

4.1. Montaggio del controller

Select a suitable, dry location for mounting the controller, away from direct heat sources or excessive moisture. The controller can be mounted on a wall using appropriate fasteners (not included). Ensure sufficient space for cable connections.

4.2. Collegamento dei cavi

The IBO S-150 controller comes with three main connections:

  1. Cavo di alimentazione: This cable supplies power to the controller. Plug it into a standard 230V, 50Hz electrical outlet.
  2. Pump Power Cable: This cable connects the controller to your central heating circulation pump. Ensure the pump is compatible with the controller's specifications (Max load: 6A).
  3. Temperature Sensor Cable: The ohmic temperature sensor should be placed in a location where it can accurately measure the water temperature of the central heating system. Typically, this is on the return pipe or a designated sensor pocket. Ensure good thermal contact for accurate readings.
IBO S-150 Central Heating Pump Controller with all cables connected

Figura 1: Oltreview of the IBO S-150 controller with its connected power, pump, and sensor cables.

Metter il fondo a view of IBO S-150 controller showing power and pump sockets

Figura 2: In basso view of the controller, illustrating the connection points for the power and pump cables.

After all connections are securely made, restore power to the central heating system.

5. Funzionamento

The IBO S-150 controller features a simple interface with two LED displays and three control buttons.

Front panel of IBO S-150 controller with LED displays and control buttons

Figure 3: Front panel of the IBO S-150 controller, showing the LED displays and control buttons.

5.1. Accensione iniziale

Upon initial power-on, the upper LED display will show the current temperature measured by the sensor. The lower LED display will show the currently set 'stop temperature'.

5.2. Pulsanti di controllo

  • Pulsante MENU: Used to cycle through and select different settings (stop temperature, start temperature, anti-freeze function). Pressing this button allows you to enter the setting mode for each parameter.
  • UP Arrow Button (▲): Used to increase the value of a selected parameter.
  • DOWN Arrow Button (▼): Used to decrease the value of a selected parameter.

5.3. Impostazione dei parametri di temperatura

  1. Premere il tasto MENU button to enter the setting mode. The lower display will start flashing, indicating you can adjust the 'stop temperature'.
  2. Utilizzare il SU (▲) E GI (▼) arrow buttons to set the desired temperature at which the pump should stop.
  3. Premere il tasto MENU button again to confirm the 'stop temperature' and move to the 'start temperature' setting. The lower display will flash again.
  4. Utilizzare il SU (▲) E GI (▼) arrow buttons to set the desired temperature at which the pump should start. This is typically a few degrees higher than the stop temperature to prevent rapid cycling.
  5. Premere il tasto MENU button a third time to confirm the 'start temperature' and exit the setting mode. The controller will return to displaying the current and stop temperatures.

5.4. Funzione antigelo

The anti-freeze function is automatically engaged. If the temperature measured by the sensor drops below 5 °C (41 °F), the pump will activate regardless of other settings to circulate water and prevent freezing. This function cannot be manually disabled.

6. Manutenzione

The IBO S-150 controller requires minimal maintenance to ensure optimal performance and longevity.

  • Pulizia: Periodically wipe the exterior of the controller with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.
  • Ispezione dei cavi: Regularly check all connected cables (power, pump, sensor) for any signs of wear, damage, or loose connections. Replace damaged cables immediately.
  • Posizionamento del sensore: Ensure the temperature sensor remains securely in its intended position and maintains good thermal contact with the heating system pipe.
  • Condizioni ambientali: Verify that the controller's operating environment remains within the specified ambient temperature and humidity ranges.

7. Risoluzione Dei Problemi

If you encounter issues with your IBO S-150 controller, refer to the following troubleshooting guide:

ProblemaPossibile causaSoluzione
Il controller non si accende.Nessuna alimentazione; cavo di alimentazione allentato; presa difettosa.Check power outlet; ensure power cable is securely plugged in; check circuit breaker.
Pump does not turn on when temperature is high.Incorrect 'start temperature' setting; faulty pump connection; pump malfunction.Verify 'start temperature' setting; check pump power cable connection; test pump independently if possible.
Pump does not turn off when temperature is low.Incorrect 'stop temperature' setting; sensor malfunction.Verify 'stop temperature' setting; check sensor connection and placement.
La lettura della temperatura non è accurata.Sensor improperly placed; faulty sensor.Ensure sensor has good thermal contact and is correctly positioned; replace sensor if necessary.
Anti-freeze function activates unexpectedly.Ambient temperature near or below 5 °C; sensor reading error.This is normal operation if ambient temperature is low. Check sensor reading for accuracy.

If the problem persists after attempting these solutions, please contact a qualified technician or the product support.

8. Garanzia e supporto

Per informazioni sulla garanzia e assistenza tecnica, consultare la documentazione fornita con l'acquisto o contattare il rivenditore. Conservare la prova d'acquisto per eventuali reclami in garanzia.

Produttore: IBO

Numero di modello: S-150