Introduzione
This manual provides essential information for the proper installation, operation, and maintenance of your DELLA 27K BTU Dual Zone Mini Split Air Conditioner & Heat Pump. Please read this manual thoroughly before installation and use to ensure optimal performance and safety. This unit is designed to provide efficient cooling and heating for multiple rooms, covering up to 2000 Sq. Ft. with its 18,000 BTU + 18,000 BTU indoor units.

Figure 1: DELLA 27K BTU Dual Zone Mini Split Air Conditioner and Heat Pump components.
Informazioni sulla sicurezza
Always adhere to local electrical codes and regulations. Professional installation is highly recommended for this system. Failure to follow these instructions may result in property damage, personal injury, or death.
- Sicurezza elettrica: Ensure the power supply matches the unit's requirements (208-230V). Use a dedicated circuit with appropriate overcurrent protection. All wiring must be securely connected and grounded.
- Gestione del refrigerante: This unit contains refrigerant. Only qualified personnel should handle refrigerant and perform vacuuming procedures. Improper handling can lead to leaks and system damage.
- Luogo di installazione: Choose a sturdy wall capable of supporting the indoor unit's weight without vibration. Ensure proper clearances around both indoor and outdoor units for optimal airflow and performance.
- Avvertenza sulla Proposta 65: Questo prodotto può esporti a sostanze chimiche, tra cui il piombo, che è noto allo Stato della California come causa di cancro e difetti alla nascita o altri danni riproduttivi. Per maggiori informazioni, vai a www.P65Warnings.ca.gov.
Prodotto finitoview
The DELLA 27K BTU Dual Zone Mini Split system offers advanced climate control with high energy efficiency. It features two indoor air handlers and one outdoor condenser, allowing for individual temperature control in separate rooms.
- Efficienza energetica: Valutazione SEER2 19 con tecnologia DC Inverter per un risparmio energetico fino al 30%.
- Comfort multizona: Two 18,000 BTU indoor units provide cooling and heating for up to 2000 Sq. Ft. total.
- Intelligenti Caratteristiche: WiFi enabled, compatible with Alexa, I Feel mode, 24-hour timer, sleep mode, ECO energy saving mode, multiple fan speeds, turbo function, heating, cooling, and dry modes.
- Funzionamento silenzioso: Funziona a soli 50 dBa, in modo estremamente silenzioso.

Figure 2: Key components of the DELLA Mini Split system.
Configurazione e installazione
Proper installation is crucial for the longevity and efficiency of your mini split system. This section outlines key considerations and steps.
Considerazioni sulla posizione di installazione
- Unità interna: Must be at least 6 inches below the ceiling for proper airflow. Ensure the wall is sturdy enough to support the unit's weight without vibration. Keep the inlet and outlet clear of obstructions. Install at least 10 feet (3 meters) away from TVs or radio appliances to prevent interference.
- Unità esterna: Must be spaced away from the wall. Ensure no plants or objects are within 3 feet of the appliance to allow for proper air circulation.
Refer to the user manual's "Installation Preview Section" for specific clearances for your model.
Handling Refrigerant Pipes
Handle refrigerant pipes with care. It is highly recommended to use a bending tool. If bending by hand, do so very slowly to prevent kinking or damage. Damaged pipes can lead to refrigerant leaks and system malfunction.
Bundling the Line Set
After installing the indoor unit, ensure the line set is angled downward and the drain pipe is pointed straight down. This allows proper liquid flow and prevents leaks.
Vacuum Pumping the Refrigerant Circuit
Vacuuming the lines is a critical step to remove air and moisture for maximum efficiency. You will need a vacuum pump, line set, gauge, and valve core removal tool.
- Vacuum for at least 15 minutes per line set, depending on your pump's strength.
- For multi-zone systems, vacuum each line set separately.
- Use a micron gauge to reach 500 microns. If using a manifold gauge, aim for -30 PSI.
- Add refrigerant if your line set exceeds 25 feet.
Connessione elettrica
Ensure a safe electrical connection. Verify your home's voltage (110V or 220V) and select the appropriate breaker size and UL-listed wire for the mini split system.
Video di installazione
Video 1: 5 Urgent Steps Need to Know Before Installing Della Mini Split. This video provides crucial pre-installation tips to ensure a smooth setup process.
Video 2: Install Your DELLA Mini Split Unit. A detailed guide on the installation process for your DELLA Mini Split.
Video 3: How to wire your Della mini split unit. This video demonstrates the correct wiring procedures for your unit.
Istruzioni per l'uso
Your DELLA Mini Split system can be controlled via the included remote control or the Della+ app for smart functionalities.
Funzioni del telecomando
The remote control allows you to access various modes and settings for your comfort.

Figure 3: DELLA Mini Split Remote Control Overview.
- Modalità: Switch between Cool, Heat, Dry, Fan Only, and Auto modes.
- Velocità della ventola: Adjust fan speed for desired airflow.
- Swing: Control vertical and horizontal airflow direction.
- Timer: Set a 24-hour timer for automatic on/off.
- Modalità risparmio: Ottimizza la temperatura e la velocità della ventola per un sonno confortevole.
- Modalità ecologica: Funzionamento a risparmio energetico.
- Funzione Turbo: Fornisce un rapido raffreddamento o riscaldamento.
Della+ App and Smart Features
Control your unit remotely and access advanced features using the Della+ app, compatible with Alexa and Google Assistant.

Figure 4: Della+ App Interface.
- Telecomando: Regola le impostazioni ovunque tu sia tramite il tuo smartphone.
- Geolocalizzazione intelligente: Automatically turns the AC unit on or off based on your location.
- Controllo vocale: Seamlessly integrates with Alexa and Google Assistant for hands-free operation.
- Pianificazione: Plan your week in advance by setting schedules for turning the unit on/off and customizing modes.
Video 4: Della Mini split app 3.0. Explore the features and functionality of the Della+ mobile application.
Video 5: Geo Location Function. Learn how to utilize the smart geo-location feature for automated climate control.
Video 6: DELLA Mini Split Air Conditioner. A general overview of the DELLA Mini Split Air Conditioner's features and benefits.
Manutenzione
Regular maintenance ensures the efficiency and longevity of your DELLA Mini Split system.
- Pulizia del filtro: Pulire regolarmente i filtri dell'aria (ogni 2-4 settimane, a seconda dell'utilizzo) per mantenere il flusso d'aria e l'efficienza. Consultare il manuale utente completo per istruzioni dettagliate sulla rimozione e la pulizia dei filtri.
- Pulizia dell'unità esterna: Keep the outdoor unit clear of debris, leaves, and other obstructions. Periodically clean the coils with a soft brush or vacuum.
- Controllo del drenaggio: Ensure the drain pipe is free of blockages to prevent water overflow from the indoor unit.
- Ispezione professionale: It is recommended to have a qualified HVAC technician inspect and service your unit annually to ensure proper operation and address any potential issues.
Risoluzione dei problemi
If you encounter issues with your DELLA Mini Split, refer to the following common troubleshooting tips. For complex problems or error codes, contact customer support.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'unità non si accende | Nessuna corrente, interruttore automatico scattato, batterie del telecomando scariche. | Controllare l'alimentazione, ripristinare l'interruttore, sostituire le batterie del telecomando. |
| Raffreddamento/riscaldamento insufficiente | Filtri dell'aria sporchi, unità esterna bloccata, impostazione della modalità errata, refrigerante basso. | Pulire i filtri, rimuovere le ostruzioni dall'unità esterna, selezionare la modalità corretta, contattare un tecnico per il controllo del refrigerante. |
| Perdita d'acqua dall'unità interna | Tubo di scarico intasato, angolo di installazione non corretto. | Clear drain pipe, ensure proper downward angle of line set. |
| Rumori o vibrazioni insolite | Loose parts, unit not level, foreign objects in fan. | Check for loose components, ensure unit is level, inspect for obstructions. |
| Error Codes (e.g., E9, E4) | System malfunction, sensor issue, refrigerant pressure issue. | Note the error code and contact DELLA customer support for diagnosis and resolution. |
Specifiche
| Caratteristica | Dettaglio |
|---|---|
| Marca | Della |
| Numero di modello | 27K+D1818 |
| Capacità di raffreddamento/riscaldamento | 27,000 BTU (Dual Zone 18,000 BTU + 18,000 BTU) |
| Valutazione SEER2 | 19 |
| Voltage | 208-230 V |
| Cosatage | 5240 Watt |
| Livello di rumore | 50 dB |
| Area di copertura | Up to 2000 Sq. Ft. (1000 Sq. Ft. per indoor unit) |
| Caratteristiche speciali | Telecomando, Alexa e Wi-Fi abilitati, raffreddamento e riscaldamento rapidi, deumidificatore |
| Peso dell'articolo | 178.7 libbre |
| Dimensioni del prodotto | 39.76 x 12.4 x 8.66 pollici |
Garanzia e supporto
DELLA offers unmatched support and a limited lifetime warranty to give you peace of mind.
- Garanzia a vita limitata: Provides comprehensive coverage for your product.
- Assistenza clienti: For any questions, technical assistance, or warranty claims, please contact DELLA directly.
- Informazioni sui contatti: Refer to your product packaging or the official DELLA website for the most current contact details (phone support M-F PST, LiveChat 24/7).