1. Introduzione

This manual provides essential information for the installation, operation, and maintenance of your Astral Pool E-Next 21 Salt Electrolyzer. Designed for simplicity and efficiency, the E-Next 21 is suitable for disinfecting swimming pools up to 90 m³. Please read this manual thoroughly before installation and use to ensure safe and optimal performance of your device.

2. Istruzioni di sicurezza

Per evitare lesioni e danni all'apparecchiatura, osservare sempre le seguenti precauzioni di sicurezza:

  • Ensure that the power supply is disconnected before performing any installation, maintenance, or repair work.
  • The installation must be carried out by a qualified professional in accordance with local electrical and plumbing regulations.
  • Never operate the electrolyzer without proper water flow. The integrated flow detector will automatically shut down the unit if there is insufficient flow.
  • Maintain the recommended salt levels in the pool water (4-6 g/L) for optimal operation and to prevent damage to the cell.
  • Tenere il dispositivo lontano dalla portata dei bambini e del personale non autorizzato.
  • Do not modify the equipment in any way. Use only genuine Astral Pool spare parts.
  • Ensure adequate ventilation around the control unit.

3. Prodotto finitoview

The Astral Pool E-Next 21 Salt Electrolyzer consists of a control unit and a self-cleaning titanium cell. It automatically disinfects your pool water by converting salt into chlorine.

3.1 Caratteristiche principali

  • Automatic disinfection for pools up to 90 m³.
  • Self-cleaning cell with automatic polarity inversion.
  • Long-life Titanium electrodes (8,000 hours).
  • Adjustable production levels (0%, 50%, 75%, 100%).
  • Connection terminal for automatic pool cover integration (reduces production to 10% when cover is closed).
  • Integrated flow detector for automatic shutdown in case of insufficient flow.
  • Salt level alarm.
  • Compact design for easy integration into most technical rooms.

3.2 Componenti

Astral Pool E-Next 21 Salt Electrolyzer control unit and cell

Figura 1: The Astral Pool E-Next 21 Salt Electrolyzer, showing both the control unit (left) and the transparent electrolytic cell (right) with its internal electrodes. This image provides a complete view dei componenti principali del prodotto.

Astral Pool E-Next 21 Control Unit

Figura 2: Avvicinamento view of the Astral Pool E-Next 21 control unit. This unit houses the electronic controls and indicators for the electrolyzer's operation, including production level LEDs and a salt indicator.

Astral Pool E-Next 21 Electrolytic Cell

Figura 3: Dettagliato view of the transparent electrolytic cell of the Astral Pool E-Next 21. This component contains the titanium electrodes responsible for converting salt into chlorine, and it is designed for easy integration into the pool's filtration system.

4. Configurazione e installazione

The E-Next 21 electrolyzer is designed for straightforward integration into your pool's filtration system. Its compact design allows for installation in most technical rooms, whether for new construction or renovation projects.

4.1 Controlli pre-installazione

  • Ensure the pool water has the correct salt concentration (4-6 g/L).
  • Verify that the filtration system is clean and functioning correctly.
  • Choose a suitable location for the control unit, protected from direct sunlight and excessive humidity.

4.2 Connecting to the Filtration System

  1. Install the electrolytic cell in the return line of the pool's filtration system, after the filter and heater (if present), and before any chemical injection points.
  2. Ensure the cell is installed horizontally or vertically according to the arrows indicating water flow.
  3. Connect the cell to the control unit using the provided cables.
  4. Connect the integrated flow detector to the designated port on the control unit. This ensures the electrolyzer only operates when water is flowing.

4.3 Collegamento elettrico

  • Connect the control unit to a dedicated electrical circuit (230 V - 50/60 Hz) protected by a residual current device (RCD).
  • If using the pool cover integration feature, connect the pool cover's auxiliary contact to the designated terminal on the electrolyzer control unit. This will automatically reduce chlorine production to 10% when the cover is closed.

5. Istruzioni per l'uso

The E-Next 21 is designed for user-friendly operation, with automatic functions linked to your pool's filtration cycles.

5.1 Starting the Electrolyzer

  • Once installed and connected, ensure the pool's filtration pump is running.
  • The electrolyzer will automatically start producing chlorine when water flow is detected.
  • The production will automatically stop when the filtration pump stops or if insufficient flow is detected.

5.2 Adjusting Production Levels

The E-Next 21 offers four adjustable production levels to match your pool's needs and size:

  • 0%: No chlorine production.
  • 50%: Reduced chlorine production.
  • 75%: Moderate chlorine production.
  • 100%: Maximum chlorine production.

Use the control buttons on the unit to select the desired production level. The current level is indicated by LEDs.

5.3 Pool Cover Integration

If connected to a pool cover, the electrolyzer will automatically reduce its chlorine production to 10% when the cover is closed. This feature helps prevent over-chlorination and prolongs equipment life.

6. Manutenzione

Regular maintenance ensures the longevity and efficiency of your E-Next 21 electrolyzer.

6.1 Self-Cleaning Cell

The E-Next 21 features a self-cleaning cell through automatic polarity inversion (every 2-3 hours). This process minimizes scale buildup on the electrodes, reducing the need for manual cleaning.

6.2 Durata degli elettrodi

The titanium electrodes are designed for a long operational life of approximately 8,000 hours under normal operating conditions and proper water chemistry.

6.3 Salt Level Monitoring

The unit includes a salt level alarm. If the salt level drops below the recommended range (4-6 g/L), the alarm will activate. Add salt to the pool water as needed to restore optimal levels.

6.4 Pulizia generale

  • Periodically inspect the electrolytic cell for any visible scale buildup. If manual cleaning is required, consult a professional or refer to specific cleaning instructions for salt cells.
  • Mantenere l'unità di controllo pulita e libera da polvere e detriti.

7. Risoluzione Dei Problemi

This section addresses common issues you might encounter with your E-Next 21 electrolyzer.

ProblemaPossibile causaSoluzione
Electrolyzer not producing chlorine (no LEDs lit or low production)
  • No water flow detected.
  • Insufficient salt level.
  • Problema di alimentazione.
  • Cell electrodes are scaled or worn.
  • Check if the filtration pump is running and water is flowing through the cell.
  • Check salt level and add salt if necessary.
  • Verificare il collegamento elettrico e l'interruttore automatico.
  • Inspect cell for scale; clean if needed. If electrodes are worn, consider cell replacement.
Salt alarm activated
  • Salt concentration too low.
  • Malfunzionamento del sensore.
  • Test pool water salt level and add salt as required.
  • If salt level is correct, contact technical support.
Electrolyzer shuts down unexpectedly
  • Lack of water flow (flow detector activated).
  • Electrical overload or fault.
  • Check filtration pump operation and ensure no blockages in the plumbing.
  • Check fuse (2A) and circuit breaker. Contact a qualified electrician if issues persist.

8. Specifiche tecniche

ParametroValore
Volume massimo della piscina90 metri cubi
Produzione di cloro21 g/ora
Recommended Salt Rate4 - 6 g/L
Polarity Inversion (Self-cleaning)Yes (every 2 - 3 hours)
Production Adjustment4 livelli: 0%, 50%, 75%, 100%
Alimentazione elettrica230 V - 50/60 Hz
Amprabbia0.4 A
Fusibile2 A
Intervallo di temperatura dell'acqua15°C - 40°C
Integrated Flow Detector
Salt Level Alarm
Riferimento produttore74083
OrigineProdotto in Europa

9. Garanzia e supporto

The Astral Pool E-Next 21 Salt Electrolyzer comes with a Garanzia di 2 anno dalla data di acquisto. La presente garanzia copre i difetti di fabbricazione in normali condizioni di utilizzo e manutenzione.

For warranty claims, technical support, or spare parts inquiries, please contact your authorized Astral Pool dealer or customer service. Ensure you have your proof of purchase and the product model number (E-Next 21, Model 74083) available.

Please note that the availability of spare parts information is not provided in the product details. For specific spare parts, please consult your dealer.

© 2023 Astral Pool. All rights reserved. Information in this manual is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.