OurLeeme 01

OurLeeme 12V 1100 GPH Automatic Bilge Pump Instruction Manual

Modello: 01

1. Introduzione

This manual provides essential information for the safe and efficient operation of your OurLeeme 12V 1100 GPH Automatic Bilge Pump. Please read these instructions carefully before installation and use, and retain them for future reference.

Caratteristiche del prodotto:

  • Basso consumo energetico: Highly efficient with very low energy usage and high capacity.
  • Dimensioni compatte: Small, lightweight design, space-saving, quiet operation, and low vibration.
  • Alta portata: Provides a large water output for rapid water evacuation.
  • Funzionamento completamente automatico: Equipped with an integrated electronic Reed sensor system for easy, fully automatic control.
  • Design impermeabile: Fully submersible and fire-resistant with anti-airlock design and moisture-tight seals.
  • Costruzione durevole: Stainless steel shaft, impact-resistant plastic housing with anti-rust and corrosion-resistant properties.
  • Protezione contro il funzionamento a secco: Designed not to burn out when running dry.
  • Utilizzo versatile: Compatible with both fresh and saltwater.
OurLeeme 12V 1100 GPH Automatic Bilge Pump

Figura 1: OurLeeme 12V 1100 GPH Automatic Bilge Pump. This image shows the compact design of the bilge pump with its white and blue casing and integrated wiring.

2. Informazioni sulla sicurezza

Please observe the following safety warnings to prevent injury or damage to the product.

Warning label with choking hazard information and CE, UKCA marks

Figure 2: Product Warning Label. This label indicates a choking hazard due to small parts, making it unsuitable for children under 3 years old. It also displays CE and UKCA compliance marks.

  • Rischio di soffocamento: Contains small parts. Keep away from children under 3 years of age.
  • Ensure all electrical connections are properly insulated and protected from water ingress.
  • Do not operate the pump if the wiring is damaged.
  • Scollegare sempre l'alimentazione prima di effettuare qualsiasi operazione di manutenzione o installazione.
  • This pump is designed for pumping water only. Do not use it for flammable liquids, chemicals, or other hazardous materials.

3. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

  • 1 x ourLeeme 12V 1100 GPH Automatic Bilge Pump

4. Specifiche

CaratteristicaSpecificazione
TipoAutomatic Bilge Water Pump
Temperatura massima43 °C (109.4 °F)
Diametro di uscita0.75 pollici (19 mm) - Note: Some packaging or reviews may incorrectly state 29mm. The actual diameter is 19mm.
Voltage12 Volt
Corrente massima3 A
Portata1100 GPH (4160 Liters per hour)
Dimensioni (L x P x A)14.5 x 7.8 x 10 cm (5.7 x 3.1 x 3.9 pollici)
Lunghezza del cavo1 metro
Peso500 grammi
MaterialeAcciaio inossidabile, plastica
Dimensioni dell'OurLeeme 12V 1100 GPH Automatic Bilge Pump

Figure 3: Product Dimensions. This image illustrates the length (14.5 cm / 5.7"), width (7.8 cm / 3.1"), and height (10 cm / 3.9") of the bilge pump.

5. Installazione e configurazione

Un'installazione corretta è fondamentale per le prestazioni e la longevità della pompa.

Montaggio:

  • Position the pump in the lowest part of the bilge or desired water collection area.
  • Ensure the pump is securely mounted to prevent movement during operation.
  • The pump is fully submersible.

Giunzione di tubi:

  • Connect a 0.75-inch (19mm) discharge hose to the pump's outlet.
  • Fissare il tubo con un tubo clamp per evitare perdite.
  • Route the discharge hose upwards and overboard, ensuring a continuous downward slope to prevent backflow.
Bilge pump installed in a boat

Figure 4: Typical Bilge Pump Installation. This image shows the bilge pump positioned within a boat's bilge, ready for operation.

6. Istruzioni per il cablaggio

Correct wiring is essential for safe and automatic operation. Always disconnect the power source before wiring.

Identificazione del filo:

  • Filo nero: Connect to the negative (-) terminal of the 12V power source.
  • Filo rosso: Connect to the positive (+) terminal for Modalità manuale operazione.
  • Filo blu: Connect to the positive (+) terminal for Modalità automatica operazione.
Close-up of bilge pump wiring connections

Figure 5: Wiring Details. This close-up shows the black (negative), red (manual positive), and blue (automatic positive) wires emerging from the pump.

Schema elettrico:

Before wiring, open the filter and remove the foam block located under the float mechanism.

Wiring diagram for automatic and manual modes

Figure 6: Wiring Diagram. This diagram illustrates connections for both Automatic Mode (Black to Battery -, Blue to Battery +) and Manual Mode (Black to Battery -, Red to Battery +). Note: The diagram shows a "Brown" wire for manual mode, but the product description and other images indicate "Red" for manual positive connection. Please follow the Red wire for manual positive connection as per the product description and Figure 5.

  • Modalità automatica: Collegare il Nero wire to the battery's negative terminal. Connect the Blu wire to the battery's positive terminal. The pump will activate automatically when the water level rises.
  • Modalità manuale: Collegare il Nero wire to the battery's negative terminal. Connect the Rosso wire to the battery's positive terminal. The pump will operate continuously as long as power is supplied.
  • It is recommended to install a fuse (not included) in the positive line for circuit protection.

7. Istruzioni per l'uso

L'OurLeeme Bilge Pump offers both automatic and manual operation modes.

Funzionamento automatico:

  • When wired for Automatic Mode (Blue wire to positive), the pump's internal float switch will detect rising water levels.
  • The pump will automatically activate when the water reaches a critical level.
  • Once the water level drops below the sensor, the pump will automatically shut off.
Sequence showing automatic bilge pump operation

Figure 7: Automatic Operation Cycle. This sequence illustrates how the pump activates when water reaches a critical level and deactivates once the water is pumped out and the level drops.

Funzionamento manuale:

  • When wired for Manual Mode (Red wire to positive), the pump will run continuously as long as power is supplied.
  • This mode is suitable for situations requiring continuous pumping or for testing the pump.
  • Always monitor the pump during manual operation to prevent dry running for extended periods, although the pump is designed not to burn out when dry.

8. Manutenzione

Regular maintenance ensures optimal performance and extends the lifespan of your bilge pump.

  • Ispezionare regolarmente: Periodically check the pump for debris, such as leaves, hair, or other foreign objects that may obstruct the intake or impeller.
  • Pulisci lo schermo di aspirazione: The pump features a removable filter/intake screen. Clean it regularly to ensure unrestricted water flow.
  • Controllare il cablaggio: Inspect all wiring connections for corrosion, fraying, or loose terminals. Ensure connections are secure and waterproof.
  • Operazione di prova: Regularly test the pump's automatic and manual functions to confirm it is operating correctly. For automatic mode, introduce water into the bilge to trigger the float switch.
  • winterization: In freezing conditions, ensure the pump is drained and protected from ice formation, or remove it for storage.

9. Risoluzione Dei Problemi

If you encounter issues with your bilge pump, refer to the following common problems and solutions:

ProblemaPossibile causaSoluzione
Pump does not turn on (Automatic Mode)
  • Nessuna alimentazione alla pompa.
  • Interruttore a galleggiante ostruito o difettoso.
  • Cablaggio errato.
  • Controllare i collegamenti della batteria e il fusibile.
  • Clear any debris around the float switch.
  • Verify Blue wire is connected to positive.
Pump does not turn on (Manual Mode)
  • Nessuna alimentazione alla pompa.
  • Cablaggio errato.
  • Controllare i collegamenti della batteria e il fusibile.
  • Verify Red wire is connected to positive.
La pompa funziona ma non viene scaricata acqua
  • Intake clogged.
  • Tubo di scarico piegato o bloccato.
  • Air lock in the pump.
  • Pulire la griglia di aspirazione.
  • Controllare e pulire il tubo di scarico.
  • Ensure the pump is fully submerged and free of air pockets.
La pompa funziona continuamente
  • Float switch stuck in the "on" position.
  • Water level not dropping below sensor.
  • Check float switch for debris or obstruction.
  • Ensure the pump is positioned correctly to fully evacuate water.

10. Garanzia e supporto

Specific warranty information is not provided in the product details. For warranty claims or technical support, please contact your retailer or the manufacturer, OurLeeme, directly. Keep your purchase receipt as proof of purchase.

© 2025 OurLeeme. All rights reserved.