Informazioni importanti sulla sicurezza

Read and understand all instructions before installing, operating, or servicing this unit heater. Failure to follow these instructions could result in property damage, personal injury, or death.

  • Sicurezza del gas: This unit uses LP (Liquid Propane) gas. Ensure all gas connections are properly sealed and tested for leaks. Installation must comply with local codes and national standards.
  • Sicurezza elettrica: Ensure the unit is properly grounded and connected to the correct power supply as specified. Disconnect power before servicing.
  • Ventilazione: Proper venting is crucial to prevent carbon monoxide poisoning. Ensure the exhaust system is correctly installed and maintained.
  • Installazione: Only qualified personnel should install and service this appliance. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, injury, or death.
  • Avvertenza sulla Proposta 65: Questo prodotto può esporti a sostanze chimiche, tra cui il piombo, che è noto allo Stato della California come causa di cancro e difetti alla nascita o altri danni riproduttivi. Per maggiori informazioni, vai a www.P65Warnings.ca.gov.

Prodotto finitoview

The Reznor UDXC-150 is a 150,000 BTU LP Gas Unit Heater designed for commercial and industrial applications such as garages, workshops, warehouses, and factories. It features a forced-air design with a low static propeller fan for efficient heat distribution.

Reznor UDXC-150 LP Gas Unit Heater

Immagine: Frontale view of the Reznor UDXC-150 LP Gas Unit Heater.

Caratteristiche principali:

  • Propane Compatibility: Designed for LP gas, suitable for various indoor commercial or industrial settings.
  • Alte prestazioni: 150,000 BTU output with two heating levels (low fire 87,150 BTU / high fire 124,500 BTU) and 83% thermal efficiency.
  • Versatilità di montaggio: Threaded-nut retainers at four suspension points allow for ceiling or wall mounting (mounting hardware sold separately).
  • Costruzione durevole: Features a TCORE2 titanium-stabilized aluminized steel heat exchanger.
  • Controlli avanzati: Patented single-burner combustion, integrated circuit board with display, built-in disconnect, and current status LED for diagnostics.

Specifiche tecniche

CaratteristicaSpecificazione
MarcaReznor (1HVAC)
Numero di modelloUDXC-150 | 1043187R
Potenza termica150,000 unità termiche britanniche (BTU)
Tipo di carburanteLiquid Propane (LP Gas) - Convertible from Natural Gas
Efficienza termica83%
Numero di velocità2 (Low Fire: 87,150 BTU / High Fire: 124,500 BTU)
Amprabbia11 Amps
Dimensioni del prodotto48.88"P x 41"L x 34.13"A
Tipo di montaggioCeiling Mount / Wall Mount (Mounting hardware sold separately)
Uso interno/esternoAl chiuso
Caratteristica specialeRiscaldamento rapido
Scambiatore di caloreTCORE2 Titanium-Stabilized Aluminized Steel
Reznor UDXC-150 Unit Heater Dimensions

Image: Diagram showing the dimensions of the Reznor UDXC-150 unit heater.

Configurazione e installazione

Proper installation is critical for the safe and efficient operation of your Reznor UDXC-150 unit heater. Consult a qualified HVAC professional for installation to ensure compliance with all local and national codes.

Controlli pre-installazione:

  • Verify that the unit's BTU output is appropriate for the space to be heated.
  • Ensure adequate clearance from combustible materials as specified in the installation manual.
  • Confirm that the gas supply (LP) and electrical supply meet the unit's requirements.
  • If converting from natural gas to LP, ensure the provided LP conversion kit is correctly installed by a qualified technician.

Montaggio:

The UDXC-150 can be ceiling-mounted or wall-mounted using appropriate brackets (sold separately). The unit includes threaded-nut retainers at four suspension points for secure attachment.

Reznor UDXC-150 Unit Heater Ceiling Mounted

Image: Reznor UDXC-150 unit heater installed and suspended from a ceiling, highlighting its mounting options.

Collegamenti gas ed elettrici:

  • Connect the LP gas supply line to the unit, ensuring all connections are tight and leak-free.
  • Wire the unit to the electrical supply according to the wiring diagram in the full installation manual. This includes connections for the fan, combustion blower, and integrated circuit board.

Sfiato:

The unit is compatible with Category I double-wall B-vent pipe for vertical or horizontal venting. Ensure the vent pipe is properly sized, installed, and sealed to safely exhaust combustion byproducts.

Istruzioni per l'uso

Once installed and all connections are verified, follow these steps to operate your Reznor UDXC-150 unit heater:

  1. Accensione: Ensure the main electrical supply to the unit is switched on.
  2. Fornitura di gas: Open the manual gas shut-off valve to allow LP gas to flow to the unit.
  3. Impostazione del termostato: Set the thermostat to your desired temperature. The unit will automatically cycle on and off to maintain this temperature.
  4. Heat Output Selection: The UDXC-150 offers two heat output levels. Refer to the full manual for instructions on how to select between low fire (87,150 BTU) for milder conditions and high fire (124,500 BTU) for colder periods.
  5. Avvio iniziale: Upon initial startup or after a prolonged shutdown, it may take a few minutes for the gas lines to purge air, and the unit may attempt ignition multiple times before successfully lighting.
  6. Fermare: To turn off the unit, lower the thermostat setting below the ambient temperature or switch off the main electrical supply. For extended shutdowns, close the manual gas shut-off valve.
Reznor UDXC-150 Heating Flexibility

Image: Graphic illustrating the heating flexibility of the Reznor UDXC-150 with its dual BTU output for varying temperatures.

Manutenzione

Regular maintenance ensures the longevity and efficient operation of your unit heater. Perform the following checks periodically:

  • Ispezione annuale: Have a qualified service technician inspect the unit annually, preferably before the heating season.
  • Pulizia: Keep the area around the heater clear of debris and obstructions. Ensure the air intake and discharge grilles are clean.
  • Controllo del sistema di ventilazione: Inspect the vent pipe for any signs of corrosion, leaks, or blockages.
  • Ispezione dei componenti: Check electrical connections for tightness and signs of wear. Inspect the fan and motor for proper operation and lubrication if required.

Risoluzione dei problemi

If your Reznor UDXC-150 unit heater is not operating correctly, refer to the following common issues before contacting a service technician:

  • Nessun riscaldamento/Unità non avviata:
    • Check if the electrical power supply is on.
    • Assicurarsi che la valvola di alimentazione del gas sia aperta.
    • Verify the thermostat is set above the ambient temperature.
    • Check the unit's integrated circuit board display and status LED for diagnostic codes. Refer to the full manual for code interpretations.
  • Calore insufficiente:
    • Confirm the unit is operating on the high fire setting if maximum heat is desired.
    • Ensure no obstructions are blocking the air intake or discharge.
    • Check for proper ventilation and insulation of the heated space.
  • Rumori o odori insoliti:
    • Immediately shut off the gas supply and electrical power.
    • Do not attempt to operate the unit. Contact a qualified service technician.

For detailed troubleshooting steps and error code explanations, consult the complete installation and operation manual provided with your unit.

Garanzia e supporto

This Reznor UDXC-150 unit heater is backed by a manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty card included with your product or contact Reznor customer support.

If you require technical assistance, parts, or service, please contact the authorized dealer or service center where you purchased the unit. Ensure you have your model number (UDXC-150) and serial number available when contacting support.

For general inquiries or to locate an authorized service provider, visit the official Reznor website or contact 1HVAC, the brand associated with this product.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.