1. Introduzione
This manual provides comprehensive instructions for the installation, operation, and maintenance of the Danfoss 25T65 Thermostat, model 077B6476. This thermostat is specifically designed for precise temperature regulation in two-part cold cabinets and various other refrigeration appliances. Adherence to these instructions ensures optimal performance and longevity of the product.
2. Informazioni sulla sicurezza
Please read and understand all safety warnings before attempting installation or operation. Failure to follow these instructions may result in property damage, personal injury, or death.
- Scollegare l'alimentazione: Always ensure the main power supply to the appliance is disconnected before beginning any installation, maintenance, or repair work.
- Installazione professionale: Installation should only be performed by a qualified technician familiar with refrigeration systems and electrical wiring.
- Evitare l'umidità: Non esporre il termostato all'acqua o a umidità eccessiva.
- Gestione corretta: Handle the capillary tube with care to avoid kinking or damage, which can affect thermostat accuracy.
- Collegamenti elettrici: Assicurarsi che tutti i collegamenti elettrici siano sicuri e conformi alle normative elettriche locali.
3. Prodotto finitoview
The Danfoss 25T65 Thermostat is a robust and reliable component engineered for accurate temperature control. It features a durable housing, a capillary tube for temperature sensing, and multiple electrical terminals for integration into refrigeration circuits.

Figura 1: Superiore view of the Danfoss 25T65 Thermostat, highlighting the central control shaft and the arrangement of electrical terminals on the side.

Figura 2: Lato view of the thermostat, illustrating the capillary tube entry point and the structural design for mounting within an appliance.

Figura 3: Un dettagliato view of the thermostat's underside or back, displaying important electrical ratings and specific connection information.

Figura 4: A close-up image of the electrical terminals, showing their size and configuration for wiring connections.
4. Specifiche
Key technical specifications for the Danfoss 25T65 Thermostat (Model 077B6476):
| Caratteristica | Specificazione |
|---|---|
| Numero di modello | Numero di modello: 077B6476 |
| Lunghezza del tubo capillare | 2,000 millimetri |
| Terminali di collegamento | 6.3 millimetri / 4.8 millimetri |
| Intervallo di temperatura (freddo) | -27 °C |
| Temperature Range (Warm) | -11 °C constant +3.5 °C |
| Dimensioni dell'alloggiamento (circa) | Dimensioni: 60 x 30 x 25 mm |
| Resistenza di isolamento | > 50 mOhm |
| Materiale esterno | Plastica |
| Applicazione | Two-part cold cabinets, various refrigeration appliances |
5. Configurazione e installazione
Installation of the Danfoss 25T65 Thermostat requires careful attention to detail and electrical safety. It is strongly recommended that installation be performed by a qualified service technician.
- Scollegare l'alimentazione: Before starting, ensure the refrigeration appliance is completely disconnected from the main power supply.
- Access Old Thermostat: Locate and carefully remove the existing thermostat from the appliance. Note the wiring configuration and capillary tube routing. Taking photos can be helpful.
- Montare il nuovo termostato: Securely mount the new Danfoss 25T65 Thermostat in the same location as the old unit.
- Collegare il cablaggio: Connect the electrical wires to the appropriate terminals on the new thermostat (6.3 mm/4.8 mm). Refer to the appliance's wiring diagram if available. Ensure connections are tight and secure.
- Route Capillary Tube: Carefully route the 2,000 mm capillary tube to the temperature sensing area within the refrigeration compartment. Avoid sharp bends or kinks in the tube. The end of the capillary tube must be positioned correctly to accurately sense the internal temperature.
- Componenti sicuri: Ensure all components are properly secured and no wires are pinched or exposed.
- Ripristina alimentazione: Una volta completata e verificata l'installazione, ripristinare l'alimentazione dell'apparecchio.
- Operazione di prova: Monitor the appliance's temperature to ensure the thermostat is functioning correctly and maintaining the desired temperature range.
6. Istruzioni per l'uso
The Danfoss 25T65 Thermostat automatically regulates the temperature within your refrigeration appliance. Once installed, its primary function is to switch the compressor on and off to maintain the set temperature range.
- Regolazione automatica: The thermostat continuously monitors the temperature via its capillary tube. When the temperature rises above the set point, it activates the cooling system. When the temperature drops to the lower set point, it deactivates the cooling system.
- Regolazione della temperatura: If your appliance has an external temperature control knob connected to this thermostat, rotate it to adjust the desired temperature setting. Turning the knob towards a colder setting will lower the average temperature, while turning it towards a warmer setting will raise it.
- Monitoraggio: Periodically check the internal temperature of your appliance with a separate thermometer to ensure it is operating within the desired range.
7. Manutenzione
The Danfoss 25T65 Thermostat is designed for long-term reliability with minimal maintenance. However, periodic checks can help ensure its continued optimal performance.
- Ispezione visiva: Annually inspect the thermostat and its connections for any signs of wear, corrosion, or damage.
- Pulizia: Ensure the area around the thermostat and the capillary tube is free from dust, debris, or ice buildup, which could impede accurate temperature sensing.
- Capillary Tube Integrity: Verify that the capillary tube is not kinked, pinched, or damaged. Any damage to the tube can compromise the thermostat's accuracy.
- Collegamenti elettrici: With power disconnected, periodically check that all electrical connections remain tight and secure.
8. Risoluzione Dei Problemi
If your refrigeration appliance is not functioning as expected, consider the following common issues before seeking professional service.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| L'apparecchio non raffredda | No power to thermostat; faulty thermostat; capillary tube damage; incorrect wiring. | Check power supply; verify wiring connections; inspect capillary tube for damage. If issues persist, professional diagnosis is required. |
| Appliance overcooling | Thermostat set too low; faulty thermostat; capillary tube improperly positioned. | Adjust temperature setting; ensure capillary tube is correctly placed to sense ambient temperature; if problem continues, thermostat may need replacement. |
| Appliance cycles too frequently | Thermostat differential too narrow; poor insulation; frequent door opening. | Check door seals; minimize door openings; if thermostat is suspected, professional evaluation is recommended. |
For problems not listed here or if troubleshooting steps do not resolve the issue, contact a qualified refrigeration technician.
9. Garanzia e supporto
For warranty information, technical support, or replacement parts, please refer to the documentation provided with your original refrigeration appliance or contact the manufacturer, Danfoss, directly. Ensure you have your product model number (077B6476) and purchase details available when contacting support.







