Tenmars TM-902

Tenmars TM-902 LAN Cable Tester User Manual

Modello: TM-902

1. Introduzione

The Tenmars TM-902 is a portable, professional test device designed for verifying and troubleshooting twisted-pair LAN cables. It provides comprehensive analysis of cable connections, identifying various faults quickly and efficiently.

This manual provides detailed instructions for the proper use and maintenance of your TM-902 LAN Cable Tester.

2. Contenuto della confezione

Prima di utilizzare il dispositivo, controllare il contenuto della confezione per assicurarsi che siano presenti tutti gli elementi:

  • 1 x TM-902 Main Unit
  • 1 x CAT5 STP Cable
  • 1 x Remote ID Unit
  • 6 batterie AAA da 1.5 V
  • 1 x Custodia per il trasporto
  • 1 x Manuale utente in inglese
Tenmars TM-902 LAN Cable Tester package contents including main unit, remote ID, cables, batteries, and carrying case.

Figure 2.1: Complete package contents of the Tenmars TM-902 LAN Cable Tester.

3. Impostazione

3.1 Installazione della batteria

  1. Locate the battery compartment on the back of the TM-902 main unit.
  2. Aprire il coperchio del vano batterie.
  3. Inserire 6 batterie AAA da 1.5 V, assicurandosi della corretta polarità (+/-).
  4. Chiudere saldamente il coperchio del vano batterie.

3.2 Collegamento dei cavi per i test

The TM-902 supports testing of UTP and STP LAN cables with RJ-45 connectors. It also includes a remote ID unit for testing installed cables.

Avvicinamento view of the RJ-45 and F-type coaxial ports on the Tenmars TM-902 LAN Cable Tester.

Figure 3.1: RJ-45 and F-type coaxial ports on the main unit.

  1. Connect one end of the LAN cable to be tested into the RJ-45 port on the main TM-902 unit.
  2. For remote testing, connect the other end of the LAN cable to the Remote ID unit. The device supports up to 8 different remote ID identifiers, though one remote ID unit is included.
  3. For direct testing of shorter cables, both ends can be connected to the main unit if applicable (though typically one end goes to the main unit and the other to the remote unit or a loopback).
Various cables and two remote ID locators for the Tenmars TM-902 LAN Cable Tester.

Figure 3.2: Included cables and remote ID locators.

4. Istruzioni per l'uso

The TM-902 features a backlit LCD screen that simultaneously displays wire-map, open circuits, short circuits, miswires, split pairs, and remote end ID numbers graphically.

The Tenmars TM-902 LAN Cable Tester main unit with its LCD screen and control buttons.

Figure 4.1: Tenmars TM-902 main unit with LCD display.

4.1 Esecuzione di un test del cavo

  1. Ensure the batteries are installed and the cable is properly connected to the main unit and remote ID (if applicable).
  2. Press the "TEST" button to initiate the cable test.
  3. Observe the backlit LCD screen for test results. The screen will graphically display the wire-map and any detected faults.
  4. The remote ID number, if connected, will also be shown on the LCD screen.

4.2 Comprensione dei risultati dei test

  • Open Circuit (Open): An open circuit indicates that a wire pair is not connected at both ends. One or more conductors in the cable do not complete the circuit, preventing the signal from reaching its destination. The TM-902 clearly shows which pins are open on the graphic display, helping to identify the problematic wire pair.
  • Short Circuit (Short): A short circuit occurs when two wires that should not be in contact directly touch each other. This can hinder data transmission and potentially damage connected devices. The TM-902 immediately identifies shorted pins and provides an alert on the screen.
  • Cablaggio errato: A miswire is a wiring error where the wire ends are connected in the wrong sequence. For example, if pin 3 connects to pin 5 instead of pin 6 at the far end, it's a miswire. Even if a physical connection exists, signals do not reach the correct line, degrading network performance. The TM-902 graphically displays mismatched connections by comparing each pin number.
  • Split Pair: A split pair is a wiring error where wire ends are connected to the correct pins but are grouped into incorrect pairs. Even if electrical continuity is maintained, this error causes interference (crosstalk) in data transmission and leads to network connection issues. The TM-902 can detect split pair errors in cables of at least 5 meters and notifies the user with a "SPLIT" warning. This type of error often results from incorrect pairing of wires during cable assembly and is not visible externally.

Nota: A minimum cable length of 5 meters is required for split pair detection.

5. Manutenzione

To ensure the longevity and accurate performance of your Tenmars TM-902 LAN Cable Tester, follow these maintenance guidelines:

  • Pulizia: Utilizzare un panno morbido e asciutto per pulire il dispositivo. Non utilizzare detergenti abrasivi o solventi.
  • Magazzinaggio: When not in use, store the device in its carrying case in a cool, dry place, away from direct sunlight and extreme temperatures.
  • Sostituzione della batteria: Replace batteries promptly when the low battery indicator appears on the screen to ensure accurate readings and prevent battery leakage. Remove batteries if the device will not be used for an extended period.
  • Maneggiare con cura: Evitare di far cadere il dispositivo o di sottoporlo a forti urti, che potrebbero danneggiare i componenti interni.
Tenmars TM-902 LAN Cable Tester with its carrying case, shown on a table.

Figure 5.1: Tenmars TM-902 with its protective carrying case.

6. Risoluzione Dei Problemi

This section provides guidance for common issues encountered during the use of the TM-902 LAN Cable Tester.

  • Il dispositivo non si accende:
    • Controllare che le batterie siano installate correttamente, con la giusta polarità.
    • Sostituisci le batterie vecchie o esaurite con nuove batterie AAA da 1.5 V.
  • Inaccurate test results or no display:
    • Ensure cable connectors (RJ-45) are fully inserted into the ports on both the main unit and the remote ID unit.
    • Verify that the cable itself is not visibly damaged.
    • Clean the RJ-45 ports if there is any visible dust or debris.
  • "SPLIT" error on short cables:
    • The TM-902 requires a minimum cable length of 5 meters to accurately detect split pair errors. Test longer cables for this specific fault.
  • Remote ID not detected:
    • Ensure the remote ID unit is properly connected to the far end of the cable.
    • Check if the remote ID unit itself is functioning (though it's a passive device, ensure its connector is clean).

7. Specifiche

Caratteristica Specificazione
Tested Cable Types UTP, STP
Wiremap Test Detects open circuit, short circuit, miswire, and split pairs.
Cable Category Types CAT5, CAT6
Test Connectors Shielded 8-pin modular jack (RJ-45)
Length Test Range Fino a 255 metri
Length Test Resolution 0.1 metro
Length Test Unit Metri
Precisione del test di lunghezza ± 10% + 1.0 meter
Display 58mm x 45mm, Backlit LCD
Temperatura e umidità di esercizio 5℃ to 40℃, below 80% RH
Temperatura e umidità di conservazione -10℃ to 60℃, below 70% RH
Fonte di alimentazione 6 batterie AAA da 1.5 V
Dimensioni Dimensioni: 156 x 73 x 35 mm
Peso 170 grammi

8. Informazioni sulla sicurezza

Prima di utilizzare il dispositivo, leggere e comprendere le seguenti precauzioni di sicurezza:

  • Non tentare di aprire o modificare il dispositivo. Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato.
  • Non esporre il dispositivo a umidità o temperature estreme.
  • Ensure correct battery polarity during installation. Remove batteries if the device is not used for extended periods to prevent leakage.
  • This device is designed for testing LAN cables. Do not connect it to live electrical circuits or power outlets.

© 2023 Tenmars. All rights reserved.