1. Prodotto finitoview
The OWON XDM1241 is a high-accuracy bench-type digital multimeter designed for precise electrical measurements. It features a 3.5-inch 480x320 TFT LCD screen with backlight, offering a clear dual-line display. With 55,000 counts and DC voltage accuracy up to 0.05%, it provides reliable readings for various applications. The device includes a built-in rechargeable lithium battery for portability and supports True RMS AC voltage/current measurement.
Key features include data recording (manual and auto, up to 1,000 points), trend analysis in chart mode, and SCPI support for computer communication. It also offers multi-function testing capabilities such as diode testing, continuity, and temperature measurement. The design incorporates an anti-burn replaceable fuse for enhanced safety.
2. Informazioni sulla sicurezza
Before operating the OWON XDM1241 Digital Multimeter, please read and understand all safety instructions. Failure to follow these instructions may result in electric shock, fire, or damage to the device.
- Sicurezza generale: Always use the multimeter according to its specifications and intended use. Do not operate the device if it appears damaged or is not functioning correctly.
- Rischio di scossa elettrica: Avoid contact with live circuits. Ensure test leads are properly connected before applying power. Do not measure voltage on circuits exceeding the maximum rated input of 1000V.
- Protezione del fusibile: The multimeter is equipped with internal fuses for protection. Only replace fuses with the specified type and rating to maintain safety. Refer to the maintenance section for fuse replacement instructions.
- Ambiente: Use the multimeter in a dry environment. Avoid exposure to moisture, extreme temperatures, or explosive atmospheres.
- Probes and Accessories: Use only test leads and accessories supplied or recommended by OWON. Ensure test leads are in good condition, free from cracks or damaged insulation.
3. Componenti e layout del prodotto
3.1 Pannello frontale
The front panel of the XDM1241 features the display, control buttons, and input terminals.

Immagine: Front panel of the OWON XDM1241 Digital Multimeter, showing the display, menu selection keys, measure function keys, power button, range/arrow keys, operate keys, and signal input terminals.
- Display: 3.5-inch TFT LCD screen for showing measurement readings and menu options.
- Menu Selection Keys: Buttons adjacent to the display for navigating menus and selecting options.
- Measure Function Keys: Buttons for selecting specific measurement functions (e.g., voltage, current, frequency, temperature).
- Pulsante di accensione: Accende o spegne il dispositivo.
- Range/Arrow Keys: Used to adjust measurement ranges or navigate through menu options.
- Operate Keys: General operation buttons for various functions.
- Ingresso segnale: Terminals for connecting test leads for different measurements (10A, mA/uA, COM, V/Ohm/Hz/Temp).
3.2 Pannello posteriore
The rear panel provides power input and communication ports.

Immagine: Rear panel of the OWON XDM1241 Digital Multimeter, highlighting the USB Type-C 5V DC power input and the USB device communication port.
- USB Type-C 5V DC Power Input: Used for charging the internal battery and powering the device. Note: This port does not support data transfer.
- Porta di comunicazione del dispositivo USB: Used for connecting the multimeter to a computer for data transfer and remote control via SCPI.
4. Impostazione
4.1 Disimballaggio e ispezione
Upon receiving your OWON XDM1241, carefully unpack all components and inspect for any signs of damage. If any damage is found, contact your supplier immediately.

Immagine: The OWON XDM1241 Digital Multimeter displayed with its standard accessories, including test leads, USB cable, and power adapter.
Il pacchetto dovrebbe includere:
- OWON XDM1241 Digital Multimeter
- Test Leads (red and black)
- Cavo USB
- Adattatore di alimentazione
- Manuale dell'utente (questo documento)
4.2 Alimentazione del dispositivo
The XDM1241 comes with a built-in rechargeable lithium battery. For initial use or if the battery is low, connect the provided power adapter to the USB Type-C port on the rear panel and plug it into a power outlet. The device can be operated while charging.
4.3 Collegamento dei puntali di prova
Always ensure the multimeter is off before connecting test leads. Connect the black test lead to the 'COM' (Common) input terminal. Connect the red test lead to the appropriate input terminal based on the measurement you intend to perform:
- VΩHz°C: Per volumetage misure di resistenza, frequenza e temperatura.
- mAμA: Per milliampere e microampmisurazioni attuali.
- 10A: For high current (up to 10 Amperes) measurements.
5. Istruzioni per l'uso
5.1 Misurazioni di base
Per eseguire una misurazione:
- Premere il tasto Energia button to turn on the multimeter.
- Connect the test leads to the appropriate input terminals for your desired measurement type.
- Select the desired measurement function using the Measure Function Keys (e.g., V for voltage, A for current, Ω for resistance).
- Collegare le sonde di prova al circuito o al componente in prova.
- Leggere il valore della misurazione sul display.
5.2 Data Record Function
The XDM1241 supports both manual and automatic data recording. Up to 1,000 data points can be stored in the internal memory. The auto recording time interval can be set from 15 ms to 9999 s.

Immagine: The multimeter's display illustrating the Data Record function setup, Math functions (MAX/MIN/Average), and the Dual Display mode showing AC voltage and frequency simultaneously.
To use the data record function:
- Premere il tasto Documentazione pulsante.
- Use the menu selection keys to choose between manual or auto record mode.
- Configure the recording interval if using auto record.
- Avvia la registrazione.
- Recorded data can be exported to a computer via the USB device communication port for further analysis.
5.3 Funzioni matematiche
The multimeter can perform various mathematical calculations on measurements, including relative, maximum, minimum, average, and dBm. This feature helps in analyzing data directly on the device.
- Premere il tasto Matematica button to access these functions.
- Select the desired calculation from the menu.
5.4 Display a doppia linea
The XDM1241 supports a dual-line display, allowing you to view two different measurement parameters simultaneously, such as AC voltage and its frequency.
- Premere il tasto Doppio pulsante per attivare o disattivare questa modalità.
5.5 Computer Communication (SCPI)
The multimeter supports SCPI commands for remote control and data transfer when connected to a computer via the USB device communication port.

Immagine: The OWON XDM1241 Digital Multimeter connected to a laptop, demonstrating its capability to communicate with a computer via the USB port for reading measurements, remote control, and data logging.
Fare riferimento all'OWON website for specific software and SCPI command documentation.
6. Manutenzione
6.1 Pulizia
Per pulire il multimetro, utilizzare un panno morbido dampened with mild detergent. Do not use abrasive cleaners or solvents. Ensure the device is powered off and disconnected from all circuits before cleaning.
6.2 Sostituzione del fusibile
The XDM1241 features an anti-burn design with replaceable fuses. The line fuse is located in a plastic fuse box below the power line input on the rear panel. A spare fuse is included for convenience.

Immagine: Interno view of the OWON XDM1241 circuit board, highlighting the locations of the 10A and mA/uA fuses, indicating a high safety rating.
Per sostituire un fusibile:
- Ensure the multimeter is powered off and disconnected from all power sources and test circuits.
- Locate the fuse compartment on the rear panel or by carefully opening the device as per service instructions (if applicable and safe to do so).
- Rimuovere con cautela il vecchio fusibile.
- Insert a new fuse of the exact same type and rating. Using an incorrect fuse can compromise safety and damage the device.
- Chiudere saldamente il vano fusibili.
6.3 Cura della batteria
To prolong the life of the rechargeable lithium battery:
- Evitare di scaricare completamente la batteria frequentemente.
- Caricare la batteria regolarmente, anche se il dispositivo non viene utilizzato per periodi prolungati.
- Conservare il dispositivo in un luogo fresco e asciutto quando non viene utilizzato.
7. Risoluzione Dei Problemi
This section provides solutions to common issues you might encounter with your XDM1241 multimeter.
| Problema | Possibile causa | Soluzione |
|---|---|---|
| Il dispositivo non si accende. | Batteria scarica o assenza di collegamento elettrico. | Connect the power adapter to the USB Type-C port and charge the battery. Ensure the power adapter is plugged into a live outlet. |
| Nessuna lettura o 'OL' (sovraccarico) visualizzato. | Funzione selezionata non corretta, circuito aperto o misurazione fuori portata. | Verify the correct function is selected. Check for continuity in the circuit. Select a higher range if available or ensure the measurement is within the device's limits. |
| Letture imprecise. | Poor test lead connection, environmental interference, or device malfunction. | Ensure test leads are securely connected. Move away from strong electromagnetic fields. If the problem persists, contact support. |
| Fuse blown during current measurement. | Current exceeded fuse rating. | Replace the fuse with one of the correct type and rating. Refer to Section 6.2. Ensure future measurements are within the device's current limits. |
| Impossibile connettersi al computer. | Incorrect USB port used, driver issue, or software problem. | Ensure you are using the USB device communication port (not the Type-C power port). Install necessary drivers. Check computer software settings. |
8. Specifiche
Below are the key specifications for the OWON XDM1241 Bench-Type Digital Multimeter.
| Parametro | Valore |
|---|---|
| Modello | XDM1241 |
| Display | 3.5-inch 480x320 TFT LCD |
| Conteggi | 55,000 |
| Volume DCtage Precisione | Fino al 0.05% |
| Vero RMS | Volume ACtage / Current Measurement |
| Data Record Points | 1,000 (manual/auto) |
| Fonte di alimentazione | Alimentato a batteria (batteria al litio ricaricabile) |
| Interfaccia di comunicazione | USB (supporto SCPI) |
| Conformità alla sicurezza | Certificazione CE, RoHS, UL |
| Componenti inclusi | Device, Test Leads, USB Cable, Power Adapter |
| Dimensioni (circa) | Dimensioni: 200 mm x 64 mm x 86.5 mm |
| Peso (circa) | 0.45 kg |
9. Garanzia e supporto
9.1 Informazioni sulla garanzia
For detailed warranty information regarding your OWON XDM1241 Digital Multimeter, please refer to the official OWON websito o contattare il punto vendita. I termini di garanzia coprono in genere i difetti di fabbricazione per un periodo di tempo specificato a partire dalla data di acquisto.
9.2 Supporto tecnico
If you encounter any issues or have questions not covered in this manual, please contact OWON technical support. Support resources, including FAQs, software downloads, and contact information, can be found on the official OWON websito:
When contacting support, please have your product model (XDM1241) and serial number ready.