Philips 196074

Manuale di istruzioni per l'apparecchio LED per esterni Philips 196074 SF100-SCT-T-G2

Model: 196074 | Part Number: SF100-SCT-T-G2-10-PCB-BZ

1. Introduzione

Thank you for choosing the Philips 196074 SF100-SCT-T-G2 Outdoor Flood LED Fixture. This manual provides essential information for the safe installation, operation, and maintenance of your new LED floodlight. Please read these instructions thoroughly before installation and retain them for future reference.

This fixture is designed for outdoor use, providing powerful and efficient illumination with selectable lumen output and color temperature options. It features a durable construction and an integrated photocell for automatic operation.

2. Istruzioni di sicurezza

AVVERTIMENTO: Per ridurre il rischio di morte, lesioni personali o danni materiali causati da incendi, scosse elettriche, parti in caduta, tagli/abrasioni e altri pericoli, leggere tutte le avvertenze e le istruzioni incluse con e sulla scatola dell'apparecchiatura e tutte le etichette dell'apparecchiatura.

  • Installation must be performed by a qualified electrician in accordance with all applicable national and local electrical codes.
  • Prima dell'installazione o della manutenzione, scollegare l'alimentazione dal fusibile o dall'interruttore automatico.
  • Garantire la fornitura voltage is compatible with the fixture's requirements (120 to 347V AC).
  • Non maneggiare apparecchi sotto tensione con le mani bagnate o quando si è in piedi su superfici bagnate o bagnate.amp superfici.
  • Use only UL-approved wire for connections.
  • This fixture is rated IP65 for protection against dust and water jets. Do not submerge.
  • Non guardare direttamente la sorgente luminosa a LED in funzione.

3. Contenuto della confezione

Prima di procedere con l'installazione, verificare che tutti i componenti siano presenti e integri.

  • Philips 196074 SF100-SCT-T-G2 Outdoor Flood LED Fixture (1 unit)
  • Yoke/Trunnion Mount (pre-attached or separate)
  • Installation Hardware (screws, washers, nuts)
  • Manuale di istruzioni (questo documento)
Philips 196074 Flood LED Fixture and mounting hardware

Image 1: Philips 196074 Flood LED Fixture with included mounting hardware. The fixture is a rectangular bronze unit with an integrated LED panel and a U-shaped yoke mount.

4. Configurazione e installazione

This fixture is designed for ground, pole, or wall mounting using the provided yoke/trunnion mount.

4.1 Preinstallazione

  1. Spegnere l'alimentazione: Ensure power to the installation area is disconnected at the circuit breaker or fuse box.
  2. Select mounting location: Choose a sturdy surface capable of supporting the fixture's weight. Ensure adequate clearance for light distribution.
  3. Preparare il cablaggio: Run appropriate electrical wiring (120-347V AC) to the chosen mounting location.

4.2 Montaggio dell'apparecchiatura

  1. Position the yoke/trunnion mount against the desired surface. Mark the drilling points.
  2. Praticare i fori pilota come indicato.
  3. Secure the yoke/trunnion mount to the surface using the provided hardware. Ensure it is firmly attached.
  4. Adjust the angle of the fixture as needed and tighten the pivot bolts on the yoke to secure its position.

4.3 Collegamento elettrico

  1. Open the wiring compartment on the fixture (if applicable) or access the wiring leads.
  2. Connect the fixture's black wire to the supply's live/hot wire.
  3. Connect the fixture's white wire to the supply's neutral wire.
  4. Connect the fixture's green or bare copper wire to the supply's ground wire.
  5. Ensure all connections are secure using UL-approved wire connectors.
  6. Close and seal the wiring compartment to maintain the IP65 rating.

5. Istruzioni per l'uso

The Philips 196074 fixture features selectable lumen output and color temperature, along with an integrated photocell for automatic dusk-to-dawn operation.

5.1 Lumen and Color Temperature Selection

Before powering on the fixture, locate the selector switches on the side or back of the unit. These switches allow you to choose the desired lumen output and color temperature.

  • Lumen Output Options: 9,540 lm, 12,320 lm, 14,800 lm
  • Opzioni temperatura colore: 3000K (Warm White), 4000K (Cool White), 5000K (Daylight)

Set the switches to your preferred combination. Changes made while the fixture is powered may not take effect immediately or may require a power cycle.

5.2 Photocell Operation

The integrated photocell automatically turns the fixture ON at dusk and OFF at dawn. Ensure the photocell sensor is not obstructed by objects, dirt, or debris, as this can interfere with its operation.

Once power is restored to the fixture, it will operate according to the photocell's light detection. There is no manual override for the photocell unless specified in advanced models (not applicable to this model).

6. Manutenzione

The Philips 196074 LED Flood Fixture requires minimal maintenance. Regular cleaning and inspection will ensure optimal performance and longevity.

  • Pulizia: Pulire periodicamente la lente e l'alloggiamento con un panno morbido eamp cloth. Do not use abrasive cleaners or solvents, as these can damage the finish or lens. Ensure power is off before cleaning.
  • Ispezione: Annually inspect the fixture for any signs of damage, loose wiring, or corrosion. Ensure mounting hardware remains secure.
  • LED: The LED light source is integrated and not user-replaceable. Do not attempt to open the sealed LED compartment.

7. Risoluzione Dei Problemi

If you experience issues with your fixture, refer to the following troubleshooting guide:

ProblemaPossibile causaSoluzione
L'apparecchio non si accende.Nessuna alimentazione elettrica.
Collegamento elettrico difettoso.
Photocell detecting too much light.
Controllare l'interruttore automatico/il fusibile.
Verify all electrical connections are secure (power off first).
Ensure photocell is not obstructed and it is dark enough for activation.
L'apparecchio rimane acceso durante il giorno.Photocell obstructed or faulty.Clean photocell sensor. Ensure no external light source is shining directly on the photocell.
La potenza luminosa è inferiore alle aspettative.Lumen selection switch set to lower output.Verify the lumen selection switch is set to the desired output (power off first).
Temperatura del colore errata.Color temperature selection switch set incorrectly.Verify the color temperature selection switch is set to the desired setting (power off first).

If the problem persists after attempting these solutions, contact Philips customer support.

8. Specifiche

CaratteristicaDettaglio
Numero di modello196074
Numero di parteSF100-SCT-T-G2-10-PCB-BZ
MarcaPhilips
TipoOutdoor Flood LED Fixture
Flusso luminoso (selezionabile)9,540 lm, 12,320 lm, 14,800 lm
Apparecchio Wattage150 L
VoltageDa 120 a 347 V CA.
Light Distribution Shape110 gradi
Fixture Sensor TypeFotocellula
Posizione di montaggioGround, Pole, Wall
Tipo di montaggioYoke/Trunnion
Color Temperature (Selectable)3000K, 4000K, 5000K
Fixture Housing ColorBronzo
Fixture Lens MaterialPolicarbonato
Grado di protezione IPGrado di protezione IP65
Peso dell'articolo8 libbre
Codice UPC190096196074

9. Garanzia e supporto

Philips products are manufactured to the highest quality standards. For information regarding warranty coverage, please refer to the warranty card included with your product or visit the official Philips lighting websito.

For technical support, troubleshooting assistance, or to inquire about replacement parts, please contact Philips customer service:

Please have your model number (196074) and part number (SF100-SCT-T-G2-10-PCB-BZ) available when contacting support.

© 2024 Philips. Tutti i diritti riservati. Le informazioni sono soggette a modifiche senza preavviso.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.