OLTEANP UPS-TK2000W

OLTEANP 2000W Sump Pump Battery Backup System Instruction Manual

Model: UPS-TK2000W | Brand: OLTEANP

1. Introduzione

This manual provides comprehensive instructions for the safe installation, efficient operation, and proper maintenance of your OLTEANP 2000W Sump Pump Battery Backup System. This system is designed to provide uninterrupted power to your sump pump during electrical outages, ensuring your basement remains dry. Please read this manual thoroughly before installation and operation to ensure optimal performance and safety.

2. Informazioni sulla sicurezza

  • Always disconnect the system from all power sources before performing any maintenance or installation.
  • Garantire un'adeguata ventilazione intorno all'unità per evitare il surriscaldamento.
  • Non esporre l'unità ad acqua, pioggia o umidità eccessiva.
  • Use appropriate personal protective equipment (PPE) during installation, especially when handling batteries.
  • Connect the system only to compatible battery types as specified in this manual.
  • Ensure all wiring connections are secure and correctly polarized to prevent electrical hazards.
  • Keep children and unauthorized personnel away from the system.

3. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

  • OLTEANP 2000W Sump Pump Battery Backup System (Main Unit)
  • Cavi della batteria (rosso e nero)
  • Manuale dell'utente (questo documento)
  • Telecomando con schermo LCD
  • Accessori di montaggio (viti, tasselli)
  • Cavo di alimentazione
  • Small Wrench (for terminals)
OLTEANP 2000W Sump Pump Battery Backup System and included accessories

Figure 3.1: The OLTEANP 2000W Sump Pump Battery Backup System with its remote control, battery cables, power cable, and small wrench.

4. Prodotto finitoview

The OLTEANP 2000W Sump Pump Battery Backup System integrates a pure sine wave inverter, a 25A battery charger, and an automatic transfer switch into one unit. It features multiple output ports and a remote LCD controller for monitoring.

4.1 Caratteristiche del pannello frontale

  • 3 prese CA: For connecting your sump pump and other AC devices.
  • Porta USB (5 V/3.1 A): Per caricare piccoli dispositivi elettronici.
  • Porta di tipo C (30 W): Per una ricarica più rapida dei dispositivi compatibili.
  • Ingresso carica CA: Connects to grid power for charging the battery and powering loads.
  • Battery Type Selection Switches (DIP Switches): Allows selection of battery chemistry (GEL, AGM/SLA, Flooded/Wet, LiFePO4).
  • Interruttore ON/OFF: Interruttore di alimentazione principale per l'inverter.
  • Fault LED (Red): Indica un guasto del sistema.
  • LED di alimentazione (verde): Indicates the system is powered on.
  • Charge Full LED (Green): Indica che la batteria è completamente carica.
  • Remote Connection Port: For connecting the LCD remote controller.
  • Fuse: Protezione da sovracorrente.
Dettagliato view of the AC side and DC side ports and controls on the OLTEANP 2000W Sump Pump Battery Backup System

Figure 4.1: Front and rear panel connections and indicators.

4.2 Remote Controller with LCD Screen

The remote controller provides real-time monitoring of the system's status, including battery voltage, uscita AC voltage, power consumption, and fault indicators. This allows for convenient monitoring without direct access to the main unit.

LCD remote controller displaying battery status, DC input voltage, uscita AC voltage, e cosatage

Figure 4.2: The remote controller's LCD screen displaying operational parameters.

5. Configurazione e installazione

The OLTEANP Sump Pump Battery Backup System is designed for easy installation with minimal wiring. Follow these steps carefully.

5.1 Montaggio dell'unità

The unit can be placed flat on a stable surface or wall-mounted using the fixed holes on the side. Ensure the mounting location is dry, well-ventilated, and away from flammable materials. Use appropriate screws and anchors for your wall type.

5.2 Collegamento della batteria

  1. Ensure the main unit is OFF before connecting batteries.
  2. Collegare il rosso cavo della batteria al positivo (+) terminal of the battery and the positivo (+) terminale sull'inverter.
  3. Collegare il nero cavo della batteria al negativo (-) terminal of the battery and the negativo (-) terminale sull'inverter.
  4. Tighten all connections securely using the provided wrench.
  5. Importante: The system requires a 12V deep-cycle battery (Lithium, AGM, Flooded/Wet). Do not use non-deep-cycle batteries.

5.3 Selezione del tipo di batteria

Before turning on the inverter, set the DIP switches on the unit to match your battery type. Refer to the table below:

Table showing DIP switch settings for different battery types: GEL, AGM/SLA, Flooded/Wet, LiFePO4

Figure 5.1: DIP switch settings for various battery chemistries.

5.4 Collegamenti di ingresso e uscita CA

  1. Plug the provided power cable into the AC Charge Input port on the inverter.
  2. Collegare l'altra estremità del cavo di alimentazione a una presa a muro standard da 120 V CA.
  3. Plug your sump pump and other desired AC devices into the 3 AC Outlets on the inverter.
  4. For permanent installations, the L, N, PE terminals can be used for direct wiring to a breaker panel by a qualified electrician.
Diagram illustrating the two modes of operation: charging the battery from AC input and powering devices from the inverter

Figure 5.2: System diagram showing AC input, battery charging, and inverter output to a sump pump.

Illustration of the 2000W Sump Pump Battery Backup System powering multiple sump pumps

Figure 5.3: The 2000W system can power multiple sump pumps with a combined wattage under 2000W.

5.5 Video di installazione

Video 5.1: Official OLTEANP video demonstrating the Sump Pump Battery Backup System installation and operation.

6. Istruzioni per l'uso

Once installed, the system operates largely automatically. Here's how to use and monitor it.

6.1 Accensione/Spegnimento

  • To power on the system, press the ON/OFF switch on the main unit. The green Power LED will illuminate.
  • Per spegnere, premere nuovamente l'interruttore ON/OFF.

6.2 Automatic Switching (UPS Function)

When grid power is available, the system charges the connected battery and passes AC power directly to your connected devices. In the event of a power outage, the system automatically switches to battery power within 12 milliseconds, ensuring continuous operation of your sump pump. When grid power is restored, it automatically switches back to grid power and resumes charging the battery.

6.3 Monitoring with Remote Controller

The remote LCD controller provides essential information:

  • Livello della batteria: Displays the current charge level of the connected battery.
  • Ingresso CC Voltage: Mostra il volume della batteriatage.
  • Volume di uscita CAtage: Visualizza il volume di uscitatage supplied to your devices.
  • Cosatage: Indica il consumo energetico attuale dei dispositivi collegati.
  • Allarmi di guasto: The screen will flash and display relevant fault codes if an issue occurs.

6.4 Modalità operative

  • Modalità di ricarica: When grid power is present, the internal 25A charger replenishes the battery.
  • Modalità inverter: Durante un'interruzione di correntetage, the system converts DC battery power to AC power for your devices.

Video 6.1: Official OLTEANP video demonstrating the Pure Sine Wave Power Inverter with Charger in operation.

7. Manutenzione

Regular maintenance ensures the longevity and reliable operation of your system.

  • Pulizia: Periodically clean the exterior of the unit with a dry cloth. Ensure ventilation openings are free from dust and debris.
  • Ispezione della batteria: Regularly check battery terminals for corrosion and ensure connections are tight. For lead-acid batteries, check electrolyte levels if applicable.
  • Prova: Periodically test the system by temporarily disconnecting grid power to ensure the automatic switching function operates correctly.
  • Magazzinaggio: If storing the unit for an extended period, ensure the battery is fully charged and disconnect it from the inverter. Store in a cool, dry place.

8. Risoluzione Dei Problemi

In caso di problemi, fare riferimento ai seguenti problemi comuni e alle relative soluzioni:

ProblemaPossibile causaSoluzione
No power output from AC outlets.Unit is off, low battery, overload, fault condition.Ensure unit is ON. Check battery charge. Reduce load. Check remote controller for fault codes.
Batteria non in carica.AC input disconnected, incorrect battery type setting, faulty battery.Verify AC input connection. Check DIP switch settings for battery type. Test battery.
Remote controller not displaying.Loose connection, unit is off.Ensure remote cable is securely connected. Verify main unit is powered on.
Il sistema si spegne inaspettatamente.Sovraccarico, surriscaldamento, basso livello di carica della batteriatage, cortocircuito.Reduce connected load. Ensure adequate ventilation. Recharge battery. Check for short circuits in wiring.

For persistent issues not covered here, please contact OLTEANP customer support.

9. Specifiche

CaratteristicaDettaglio
Numero di modelloUPS-TK2000W
Cosatage2000 Watt
Ingresso volumetage (CC)12 Volt
Uscita CAPure Sine Wave, 120V AC
Caricabatterie25A (DC-AC Quick Charge)
MaterialeAcciaio inossidabile
Peso dell'articolo15.47 libbre
Dimensioni del pacco20.2 x 12.9 x 6.6 pollici
Stile di visualizzazioneLCD (Remote Controller)
Componenti inclusi2000W Sump Pump Battery Backup System, Battery Cables, User Manual, Remote Controller
Batterie incluseNO
Batterie richieste

10. Garanzia e supporto

For warranty information and customer support, please refer to the documentation included with your purchase or visit the official OLTEANP webluogo. Conserva la ricevuta di acquisto per eventuali richieste di garanzia.

© 2026 OLTEANP. Tutti i diritti riservati.

Documenti correlati - UPS-TK2000W

Preview Manuale utente inverter di potenza OLTEANP
Questo manuale utente fornisce istruzioni complete e linee guida di sicurezza per l'utilizzo degli inverter di potenza a onda sinusoidale pura OLTEANP. Scopri di più su installazione, caratteristiche, risoluzione dei problemi e specifiche per modelli come i modelli da 3000 W, 2000 W e 1500 W.
Preview Manuale utente e specifiche tecniche dell'inverter di potenza per pompa di sentina VEVOR serie SGPC
Manuale utente completo e specifiche tecniche per gli inverter di potenza per pompe di sentina VEVOR, modelli SGPC-1500W, SGPC-2000W, SGPC-2500W e SGPC-3000W. Include informazioni su installazione, sicurezza, funzionamento, risoluzione dei problemi e componenti.
Preview Manuale del prodotto inverter/UPS a onda sinusoidale pura VOLT POLSKA sinusPRO W
Manuale completo del prodotto per l'inverter/UPS a onda sinusoidale pura VOLT POLSKA serie sinusPRO W, che illustra caratteristiche, precauzioni di sicurezza, funzionamento, installazione e specifiche tecniche. Include informazioni sulla garanzia e linee guida per il corretto smaltimento.
Preview Manuale del prodotto Volt Polska sinusPRO W Pure Sine Wave Inverter/UPS
Manuale completo del prodotto per la serie Volt Polska sinusPRO W di inverter/UPS a onda sinusoidale pura, che comprende caratteristiche, precauzioni di sicurezza, descrizioni operative, parametri tecnici e linee guida per l'installazione.
Preview Battle Born 2000W Inverter/Charger: Product Manual & Installation Guide
Comprehensive product manual and installation guide for the Battle Born 2000W Inverter and Inverter/Charger. Learn about features, installation, operation, configuration, and troubleshooting for reliable power solutions.
Preview HOULI Power Inverter 12V na 230V: UPS s čistou sinusovkou - Návod a specifikace
Kompletní návod k použití a technické specifikace pro HOULI Power Inverter s funkcí UPS a čistou sinusovkou. Zjistěte více o instalaci, bezpečnosti a vlastnostech tohoto měniče napětí.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.