Loom Solar Fusion

Manuale utente dell'inverter solare Loom Solar Fusion 3kW On-Grid

Marca: Loom Solar | Modello: Fusion 3kW, 1Phase

1. Introduzione

This user manual provides essential information for the safe and efficient operation, installation, and maintenance of your Loom Solar Fusion 3kW, 1Phase On-Grid Solar Inverter. Please read this manual thoroughly before installation and operation, and keep it for future reference.

Loom Solar Fusion 3kW On-Grid Solar Inverter

Figure 1: Loom Solar Fusion 3kW On-Grid Solar Inverter, front view.

2. Informazioni sulla sicurezza

Safety is paramount when dealing with electrical equipment. Adhere to all local and national electrical codes. Only qualified personnel should perform installation and maintenance.

  • Intelligent AFCI (Arc-fault Circuit Interrupter) Protection: The inverter is equipped with AFCI protection that cuts off DC arcs within 0.5 seconds to prevent potential fire hazards.
  • Protezione contro le sovratensioni CA/CC: Integrated lightning protection safeguards the inverter and connected systems from electrical surges.
  • Protezione IP65: The inverter's robust design ensures it is dustproof, waterproof, and anti-salt fog, providing durability in various environmental conditions.
  • Always disconnect all power sources (DC and AC) before performing any service or maintenance.
  • Non tentare di aprire o riparare l'inverter da soli. Rivolgersi a personale qualificato.
Safety Shield Icon

Sicurezza superiore

Icona del fulmine

Protezione contro le sovratensioni

3. Caratteristiche del prodotto

The Loom Solar Fusion 3kW On-Grid Solar Inverter is designed with advanced technology to provide reliable and efficient solar power conversion for residential applications.

  • Alta efficienza: Achieves an industry-leading conversion efficiency of 98% through advanced power electronics technologies.
  • Monitoraggio remoto: Supports remote monitoring via GPRS/Wifi Kit, WLAN, and Ethernet, allowing you to track performance from anywhere.
  • Wide MPPT Voltage Gamma: Features an extra-wide Maximum Power Point Tracking (MPPT) voltage range for optimized energy harvesting.
  • Design robusto: Built to withstand extreme weather conditions including high temperatures, snow, sandstorms, and rain.
  • Design intelligente: Easy to install with an intuitive LED display for local monitoring.
On-Grid Solar Inverter features: Max 98.1% Efficiency, AC/DC Lightening Protection, Reliable Heat Dissipation, Various Complex Grid Adaptable

Figure 2: Key features of the Loom Solar On-Grid Solar Inverter.

4. Configurazione e installazione

Installation of the Loom Solar Fusion inverter should only be performed by certified and qualified solar professionals. Improper installation can lead to equipment damage, personal injury, or voiding of warranty.

  • Selezione del sito: Choose a well-ventilated area, protected from direct sunlight and excessive moisture. Ensure adequate clearance around the inverter for heat dissipation.
  • Montaggio: Securely mount the inverter to a sturdy wall or frame using appropriate hardware.
  • Collegamenti elettrici: Connect the DC input from the solar panels and the AC output to the grid according to the wiring diagram provided in the full installation guide (not included in this manual). Ensure all connections are tight and correctly polarized.
  • Messa a terra: Properly ground the inverter as per local electrical codes.

5. Istruzioni per l'uso

Once installed and connected, the Loom Solar Fusion inverter operates largely automatically. It will convert DC power from your solar panels into AC power for your home and the grid.

  • Avvio iniziale: After all connections are verified, switch on the DC isolator and then the AC breaker. The inverter will perform self-tests and begin operation.
  • Display a LED: The front panel features an LED display that provides real-time operational status, power output, and error codes. Refer to the full manual for a detailed explanation of display messages.
  • Monitoraggio remoto: For detailed performance tracking, connect the inverter to your network using the GPRS/Wifi Kit, WLAN, or Ethernet. Download the Loom Solar mobile application to monitor your system remotely.
Hand holding a smartphone displaying the Loom Solar monitoring app with an inverter in the background.

Figure 3: Remote monitoring via the Loom Solar mobile application.

6. Manutenzione

Una manutenzione regolare garantisce la longevità e le prestazioni ottimali del vostro inverter solare.

  • Pulizia: Periodically clean the inverter's exterior with a soft, dry cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Ispezione visiva: Controllare regolarmente eventuali danni visibili al casing, cables, or connections.
  • Monitoraggio delle prestazioni: Utilize the remote monitoring system to track the inverter's performance and identify any anomalies early.
  • Check-up professionale: It is recommended to have a qualified technician perform a comprehensive inspection and maintenance check annually.

7. Risoluzione Dei Problemi

This section provides general guidance for common issues. For complex problems, contact Loom Solar customer support.

ProblemaPossibile causaSoluzione
L'inverter non produce energiaNo sunlight, DC isolator off, AC breaker off, grid outage, error code displayed.Check sunlight conditions. Ensure DC isolator and AC breaker are ON. Verify grid status. Check inverter display for error codes and consult the full manual.
Bassa potenza in uscitaPartial shading on panels, dirty panels, suboptimal weather, system fault.Clear any shading. Clean solar panels. Monitor weather conditions. If issue persists, contact support.
Messaggio di errore sul displayInternal fault, grid issue, connection problem.Note down the error code. Refer to the detailed error code section in the comprehensive manual or contact Loom Solar support.

8. Specifiche

Detailed technical specifications for the Loom Solar Fusion 3kW On-Grid Solar Inverter.

Loom Solar Fusion 31 PV Grid-Tied Inverter Specifications Table

Figure 4: Detailed technical specifications for Fusion 31 inverter.

AttributoValore
ProduttoreTELAIO SOLARE PVT. LTD.
Numero modello articoloFusione
Dimensioni del prodotto (L x P x A)Dimensioni: 28 x 18.5 x 31 cm
Peso dell'articolo6 kg
Quantità netta1 Conteggio
Nome genericoInvertitore
MarcaLoom Solar
Usi consigliati per il prodottoCasa
Fonte di alimentazioneAlimentato ad energia solare
Cosatage3000 Watt
Nome del modelloFusione 31
Potenza massima in ingresso3000 W + 10%
Max. DC I/P (Vdc)550V
Max. MPPT Voltage Gamma70-550 V
Corrente di ingresso massima20A
Potenza CA nominale3000W
Frequenza nominale della rete50Hz (±5%)
Vol. griglia nominaletage230V
Corrente di uscita nominale14.3 Amp
Fattore di potenza0.8
Protezione di ingressoGrado di protezione IP65
Temperatura ambiente di esercizioTemperatura di esercizio -25°C ~ +65°C

9. Garanzia

The Loom Solar Fusion 3kW On-Grid Solar Inverter comes with a 5 anni di garanzia, garantendo tranquillità e prestazioni affidabili.

To log a complaint or register your warranty, please visit the official Loom Solar warranty registration portal:

Registra la tua garanzia qui

10. Supporto

For any technical assistance, queries, or support regarding your Loom Solar Fusion inverter, please contact us:

  • Contatto dell'assistenza clienti: 8447921124
  • E-mail: sales@loomsolar.com
  • Websito: www.loomsolar.com
  • Indirizzo del produttore: LOOM SOLAR PVT. LTD., Plot no. 14/8, Mathura Road, Sector - 27B, Faridabad - 121003

© 2024 Loom Solar. All rights reserved.

Ask a question about this manual