MDWXDOFP AHD12

MDWXDOFP AHD12 Series Variable Frequency Drive

Instruction Manual for 380V 3-Phase Models

Informazioni importanti sulla sicurezza

AVVERTIMENTO: Read this user manual thoroughly before operation. Failure to follow instructions may result in serious injury or equipment damage.

RISCHIO DI SCOSSA ELETTRICA: Always wait at least 10 minutes after removing power before servicing the unit to allow capacitors to discharge.

Davanti view of two MDWXDOFP AHD12 VFD units, showing the control panel and a warning label.

Immagine: Frontale view of two AHD12 VFDs, highlighting the control panel and safety warning.

1. Prodotto finitoview

The MDWXDOFP AHD12 series Variable Frequency Drive (VFD) is an economical inverter designed for controlling the speed of 3-phase AC motors. It converts fixed-frequency, fixed-voltage potenza CA in frequenza variabile, volume variabiletage AC power, enabling precise motor speed regulation and energy savings.

Caratteristiche principali:

  • Ingresso volumetage: 380 V trifase
  • Volume di uscitatage: 380 V trifase
  • Economical and reliable design
  • Integrated control panel for easy operation
  • Suitable for various industrial applications requiring motor speed control
Davanti e di lato view of the MDWXDOFP AHD12 VFD, showing the ventilation grilles and compact design.

Immagine: frontale e laterale view of the AHD12 VFD, illustrating its compact form factor.

2. Configurazione e installazione

2.1 Montaggio

Mount the VFD vertically on a flat, non-flammable surface in an environment free from excessive dust, moisture, corrosive gases, and direct sunlight. Ensure adequate ventilation space around the unit (at least 10 cm on all sides) for proper heat dissipation.

2.2 Cablaggio

Tutti i cablaggi devono essere eseguiti da personale qualificato in conformità con le normative elettriche locali e nazionali. Assicurarsi che l'alimentazione sia scollegata prima di effettuare qualsiasi collegamento.

  • Potenza assorbita (R, S, T): Connect the 380V 3-phase AC power supply to the R, S, T terminals.
  • Uscita motore (U, V, W): Connect the 3-phase motor to the U, V, W terminals.
  • Messa a terra (PE): Connect the ground terminal (PE) to a reliable earth ground.
  • Terminali di controllo: Refer to the detailed wiring diagram in the full manual for control signal connections (e.g., start/stop, speed reference, fault output).
Lato view of the MDWXDOFP AHD12 VFD with the terminal cover removed, showing input (RST), output (UVW), and control terminals.

Immagine: Lato view of the AHD12 VFD with the terminal block exposed, indicating connection points for power input, motor output, and control signals.

Posteriore view of the MDWXDOFP AHD12 VFD, showing cooling fins and additional connection points.

Immagine: Posteriore view of the AHD12 VFD, illustrating the cooling fins and potential additional connection points.

3. Istruzioni per l'uso

3.1 Pannello di controllo Sopraview

The VFD features an intuitive control panel with a digital display and various buttons for operation and parameter setting.

  • RUN/STOP/RESET: Buttons for starting, stopping, and resetting the VFD.
  • PRG (Programma): Entra/esce dalla modalità di impostazione dei parametri.
  • MF (Multifunzione): Utilizzato per varie funzioni a seconda della modalità.
  • Frecce su/giù: Navigare tra i parametri o regolare i valori.
  • ACCEDERE: Conferma le selezioni o le modifiche dei parametri.
  • Potentiometer Knob: Typically used for analog speed reference adjustment.

3.2 Funzionamento di base

  1. Accensione: Apply 380V 3-phase power to the VFD. The display will illuminate.
  2. Avviamento del motore: Premere il tasto CORRERE pulsante. Il motore accelererà fino alla frequenza impostata.
  3. Regola la velocità: Use the potentiometer knob or the Up/Down arrow buttons (depending on parameter settings) to adjust the output frequency and motor speed.
  4. Arresto motore: Premere il tasto ARRESTO/RIPRISTINO pulsante. Il motore decelera e si ferma.

3.3 Impostazioni dei parametri

The AHD12 VFD has numerous parameters to customize its operation. Refer to the complete user manual for a detailed list and explanation of all parameters. Common parameters include:

  • Domanda 0.01: Frequenza di uscita massima
  • Domanda 0.02: Frequenza di base
  • Domanda 0.03: Tempo di accelerazione
  • Domanda 0.04: Tempo di decelerazione
  • Domanda 0.05: Corrente nominale del motore

To enter parameter setting mode, press the PRG button. Use the Up/Down arrows to navigate parameters and ENTRARE to select and confirm values.

4. Manutenzione

Una manutenzione regolare garantisce prestazioni ottimali e prolunga la durata del tuo VFD.

  • Pulizia: Periodically clean the VFD's exterior and ventilation grilles to prevent dust accumulation, which can hinder cooling. Use a soft, dry cloth. Do not use liquid cleaners.
  • Ispezione: Regularly inspect wiring connections for tightness and signs of damage. Check for any unusual noises or odors during operation.
  • Condizioni ambientali: Assicurarsi che l'ambiente operativo rimanga entro gli intervalli di temperatura e umidità specificati.
  • Controllo della ventola: Verificare che la ventola di raffreddamento funzioni liberamente e non sia ostruita.

Always disconnect power and wait 10 minutes before performing any maintenance or inspection.

5. Risoluzione Dei Problemi

This section covers common issues and their potential solutions. For complex problems, contact technical support.

ProblemaPossibile causaSoluzione
Il VFD non si accendeNessuna alimentazione in ingresso; fusibile bruciatoCheck power supply; Replace fuse
Il motore non funzionaIncorrect wiring; Motor parameters not set; Emergency stop activeVerify wiring; Set motor parameters (P0.05); Check emergency stop circuit
Guasto da sovracorrente (OC)Sovraccarico del motore; Cortocircuito; Rapida accelerazioneReduce load; Check motor/cables; Increase acceleration time (P0.03)
Sovravoltagguasto e (OV)Alto volume di ingressotage; Rapid decelerationControllare l'input voltage; Increase deceleration time (P0.04)

6. Specifiche

The MDWXDOFP AHD12 series offers various power ratings. Below are the general specifications for 380V 3-phase input models.

ModelloPotenza (KW)Corrente di uscita (A)
D12-T3-0R7G0.753
D12-T3-1R5G1.54
D12-T3-2R2G2.25

Ingresso volumetage: 380V 3 fasi

Volume di uscitatage: 380V 3 fasi

Peso dell'articolo: Approximately 50 Grams (for 1.5KW model)

Produttore: MDWXDOFP

Image showing multiple MDWXDOFP AHD12 VFD units and a table detailing model numbers, power ratings in KW, and corresponding output currents in Amperes for both 380V 3-phase and 220V single-phase input models.

Image: Model specification table for AHD12 series, including power and output current ratings.

7. Garanzia e supporto

This product comes with a standard manufacturer's warranty. For warranty details, technical support, or service inquiries, please refer to the contact information provided with your purchase or visit the official MDWXDOFP websito.

© 2023 MDWXDOFP. All rights reserved.