OWON SDS210

Owon SDS210 Digital Oscilloscope User Manual

Modello: SDS210

1. Introduzione

The Owon SDS210 is a high-performance 100 MHz, 2-channel digital oscilloscope designed for accurate signal analysis. With a real-time sampling rate of 1 GS/s and a 20M record length, it provides comprehensive waveform capture and analysis capabilities. This manual provides essential information for setting up, operating, and maintaining your SDS210 oscilloscope.

  • Larghezza di banda 100 MHz: Capable of analyzing signals up to 100 MHz.
  • 2 canali: Allows simultaneous analysis of two signals.
  • 1 GS/s Real-time Samptasso di ling: Ensures detailed capture of transient events.
  • 20M Record Length: Provides extensive waveform storage for in-depth analysis.
  • Display LCD TFT da 7 pollici: Clear visualization of waveforms and measurement data.
  • 30 Automatic Measurements: For quick and precise waveform parameter analysis.
  • Analisi dello spettro FFT: Advanced signal analysis in the frequency domain.
  • Connettività USB: Supports USB Host and USB Device interfaces for data transfer and PC control.

2. Informazioni sulla sicurezza

Si prega di leggere attentamente tutte le istruzioni di sicurezza prima di utilizzare il dispositivo. La mancata osservanza di queste istruzioni può causare lesioni personali o danni allo strumento.

  • Utilizzare solo l'adattatore di alimentazione fornito con lo strumento.
  • Do not operate the oscilloscope in wet or damp condizioni.
  • Garantire una ventilazione adeguata per evitare il surriscaldamento.
  • Non tentare di riparare o modificare lo strumento autonomamente. Per qualsiasi intervento di assistenza, rivolgersi a personale qualificato.
  • Always connect the probe ground lead to earth ground before connecting the probe tip to the circuit under test.
  • Osserva tutti i voltage ratings and input limits specified for the oscilloscope and probes.

3. Prodotto finitoview

3.1 Pannello frontale

The front panel features the main display, control buttons, and input connectors.

Owon SDS210 Oscilloscope Front and Rear Panel with Labeled Components

Figure 3.1: Front and Rear Panel Layout with Key Components. This image shows the Power Switch, Function Keys, Button and Knob Control Area, Oscilloscope Signal Input Ports (CH1, CH2), Probe Compensation Output, USB Host Interface, Foldable Handle, Ventilation Holes, Power Socket, and USB Device Interface.

  • Interruttore di alimentazione: Turns the oscilloscope on or off.
  • Tasti funzione: Access various menus and settings.
  • Button and Knob Control Area: Includes controls for vertical, horizontal, trigger, and menu navigation.
  • Oscilloscope Signal Input Port (CH1, CH2): BNC connectors for connecting probes to input signals.
  • Probe Compensation Output: 5V/1kHz signal output for probe calibration.
  • Interfaccia host USB: For connecting USB storage devices to save or retrieve data.

3.2 Pannello posteriore

The rear panel includes the power input and additional connectivity options.

  • Manico pieghevole: Per una facile trasportabilità.
  • Fori di ventilazione: Essenziale per la dissipazione del calore.
  • Presa di alimentazione: Si collega all'alimentazione CA.
  • Interfaccia dispositivo USB: Used to connect the oscilloscope to a PC for data transmission and remote control.

4. Impostazione

4.1 Disimballaggio

Carefully remove the oscilloscope and all accessories from the packaging. Verify that all components listed in the packing list are present and undamaged. Keep the original packaging for future transport or storage.

4.2 Collegamento di alimentazione

  1. Connect the provided power cord to the power socket on the rear panel of the oscilloscope.
  2. Collegare l'altra estremità del cavo di alimentazione a una presa di corrente CA dotata di messa a terra.

4.3 Collegamento della sonda

Connect the oscilloscope probes to the CH1 and CH2 BNC input ports on the front panel. Ensure the connectors are securely twisted into place.

4.4 Compensazione sonda

Before taking measurements, it is crucial to compensate your probes to ensure accurate readings. This process matches the probe's capacitance to the oscilloscope's input capacitance.

  1. Set the probe attenuation to 10X.
  2. Connect the probe tip to the Probe Compensation Output terminal (5V/1kHz) on the front panel.
  3. Connect the probe's ground clip to the ground terminal next to the compensation output.
  4. Press the AUTO button to automatically adjust the waveform.
  5. Observe the square wave displayed on the screen. Adjust the trimmer capacitor on the probe until the square wave corners are flat, without overshoot or undershoot.

4.5 PC Connection (USB Device Interface)

To connect the oscilloscope to a computer for remote control or data transfer:

  1. Use a standard USB cable to connect the USB Device Interface port on the rear panel of the oscilloscope to a USB port on your computer.
  2. Install the necessary drivers and software provided by OWON for your specific operating system.

5. Funzionamento di base

5.1 Accensione/Spegnimento

Press the Power Switch on the front panel to turn the oscilloscope on. Press it again to turn it off.

5.2 Fine displayview

The SDS210 features a 7-inch TFT LCD display that provides a clear view of waveforms, measurement results, and instrument settings.

Owon SDS210 Oscilloscope 7-inch TFT LCD Display showing zoomed waveform

Figure 5.2: 7-inch TFT LCD Display. All signals and screen information can be clearly viewed. It has a same-screen display function, which can zoom in and observe signal details.

5.3 Visualizzazione della forma d'onda di base

After connecting a signal to an input channel, press the AUTO button. The oscilloscope will automatically adjust the vertical, horizontal, and trigger settings to display a stable waveform.

5.4 controlli verticali

The vertical controls adjust the amplitude and position of the waveform.

  • Vertical Position Knob: Moves the waveform up or down on the screen.
  • Vertical Scale Knob (V/div): Adjusts the vertical sensitivity (volts per division).
  • Pulsanti CH1/CH2: Selects the active channel for adjustments or turns channels on/off.

5.5 controlli orizzontali

The horizontal controls adjust the time base and position of the waveform.

  • Horizontal Position Knob: Moves the waveform left or right on the screen.
  • Horizontal Scale Knob (s/div): Adjusts the time base (seconds per division).

5.6 controlli di attivazione

The trigger controls stabilize repetitive waveforms and capture single-shot events.

  • Trigger Level Knob: Imposta il volumetagil livello in cui si verifica l'innesco.
  • Trigger Menu Button: Accesses trigger settings such as edge, pulse, video, and slope.
  • Force Button: Forces a trigger event.

6. Funzionalità avanzate

Owon SDS210 Oscilloscope showing various advanced measurement and analysis modes

Figure 6.0: Advanced Measurement and Analysis Modes. This image illustrates the 6-digit High-precision Frequency counter, FFT Spectrum Analysis, Cursor Measurements, 30 Automatic Waveform Measurements, Save/Recall functions, and X-Y mode.

6.1 Misurazioni automatiche

The SDS210 offers 30 types of automatic waveform measurements for quick and accurate analysis of signal parameters. Press the MEASURE button to access the automatic measurement menu.

  • Common measurements include Period, Frequency, Mean, Peak-PK, RMS, Max, Min, Top, Base, Amplitude, Overshoot, Preshoot, Rise Time, Fall Time, Pulse Width, Delay, Duty Cycle, and more.

6.2 FFT Spectrum Analysis

Perform Fast Fourier Transform (FFT) to analyze signals in the frequency domain. This is useful for identifying harmonics, distortion, and noise components.

  1. Press the MATH button.
  2. Select 'FFT' from the Math menu.
  3. Adjust the FFT settings such as source, window type, and display format.

6.3 Misurazioni del cursore

Use cursors to manually measure specific points on a waveform. Press the CURSOR button to activate and control the cursors.

  • Voltage Cursors: Misura volumetage differences (ΔV).
  • Time Cursors: Measure time differences (ΔT).

6.4 Save/Recall Waveforms

The oscilloscope allows you to save and recall waveform data and instrument settings to internal memory or a connected USB drive.

  1. Press the SAVE button to access saving options.
  2. Select the desired save type (waveform, setup, image) and destination (internal, USB).

6.5 X-Y Mode

X-Y mode is used to display the relationship between two signals, often for phase comparison or Lissajous figures.

  1. Ensure signals are connected to CH1 and CH2.
  2. Access the Display menu and select X-Y mode.

6.6 Controllo remoto e software

The SDS210 supports remote control and secondary development via its USB Device Interface, utilizing SCPI (Standard Commands for Programmable Instruments) and LabVIEW functions. Free computer software and programming development demos are available to facilitate remote instrument control.

Owon SDS210 Oscilloscope connected to a laptop for remote control and software development

Figure 6.6: Remote Control and Secondary Development. Communicate with a PC via the USB Device interface, supporting SCPI and LabVIEW functions. Free computer software and programming development demos are provided for remote control and secondary development.

7. Manutenzione

7.1 Pulizia

Per pulire lo strumento, utilizzare un panno morbido dampened with a mild detergent. Do not use abrasive cleaners or solvents that could damage the casing or display. Ensure the instrument is powered off and disconnected from the power source before cleaning.

7.2 Conservazione

When not in use for extended periods, store the oscilloscope in a dry, dust-free environment. Use the original packaging for protection during storage or transport.

7.3 Ventilazione

The oscilloscope is equipped with ventilation holes on the rear panel to prevent overheating. Ensure these holes are not obstructed during operation to allow for proper airflow.

8. Risoluzione Dei Problemi

Questa sezione fornisce soluzioni ai problemi più comuni che potresti riscontrare.

  • Nessun potere: Check the power cord connection and the power outlet. Ensure the power switch is in the 'ON' position.
  • Nessuna visualizzazione della forma d'onda: Verify that a signal is connected to the input channel. Check probe connections and ensure the channel is enabled. Press the AUTO button to automatically adjust settings.
  • Forma d'onda instabile: Adjust the trigger level and trigger settings (e.g., edge, slope). Ensure the trigger source is correctly selected.
  • Misurazioni imprecise: Perform probe compensation as described in Section 4.4. Check the probe attenuation setting on both the probe and the oscilloscope.
  • Problemi di connessione USB: Ensure the correct drivers are installed on your PC. Try a different USB cable or port.

If the problem persists, contact OWON customer support or your local distributor for assistance.

9. Specifiche

The following table details the technical specifications for the Owon SDS210 Digital Oscilloscope.

Owon SDS210 Series Oscilloscope Specifications Table

Figure 9.0: Owon SDS210 Series Oscilloscope Specifications. This table provides detailed specifications including Bandwidth, Sample Rate, Acquisition Mode, Input Coupling, Input Impedance, Probe Attenuation Factor, Record Length, Horizontal Scale, Vertical Sensitivity, Automatic Measurement types, Waveform Math functions, Waveform Storage, Lissajous Figures, Trigger Type, Communication Interface, Frequency Counter, and Waveform Generator Specifications (for SDS210S, SDS215S, SDS220S models).

CaratteristicaSpecification (SDS210)
ProduttoreOvunque
Numero di modelloSDS210-OW
Larghezza di banda100 MHz
Canali2 canale
Sampla tariffa1 GS/s
Lunghezza del record20 milioni
Modalità di acquisizioneNormal, Peak detect, Averaging
Ingresso AccoppiamentoCC, CA, Terra
Impedenza di ingresso1MΩ±2%, in parallel with 20 pF±5 pF
Fattore di attenuazione della sonda1X, 10X, 100X, 1000X
Horizontal Scale (s/div)2 ns/div-1000 s/div, step by 1-2-5
Sensibilità verticale2 mV/div-10 V/div
Misurazione automaticaPeriodo, Frequenza, Media, PK-PK, RMS, Max, Min, Superiore, Base, Amplitude, Overshoot, Preshoot, Rise Time, Fall Time, +PulseWidth, -PulseWidth, +Duty Cycle, -Duty Cycle, Delay A→B↑, Delay A→B↓, Cycle RMS, Cursor RMS, Screen Duty, Phase, +PulseCount, -PulseCount, RiseEdgeCnt, FallEdgeCnt, Area, and Cycle Area.
Matematica delle forme d'onda+, -, ×, ÷, FFT
Memorizzazione delle forme d'onda16 forme d'onda
Lissajous's Bandwidthfull bandwidth
Lissajous's Figure Phase Difference±3 gradi
Tipo di triggerBordo, Video
Interfaccia di comunicazioneHost e dispositivo USB
Contatore di frequenzadisponibile
Dimensioni del prodotto (L x P x A)29.97 x 7.01 x 15.24 cm (11.8 x 2.76 x 6 pollici)
Peso del prodotto1.1 chilogrammi (38.8 once)

10. Garanzia e supporto

10.1 Informazioni sulla garanzia

For detailed warranty information, please refer to the warranty card included with your product or contact your authorized OWON dealer or the manufacturer directly. Warranty terms and conditions may vary by region and retailer.

10.2 Assistenza clienti

If you require technical assistance, have questions about your product, or need to report an issue, please contact OWON customer support. Contact information can typically be found on the manufacturer's official websito o tramite la documentazione del prodotto.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.