Introduzione

The OFFNOVA 2-in-1 Resin Heating Mat & Leveling Table is designed to enhance your resin crafting experience by combining efficient resin curing with precise leveling capabilities. This device helps achieve professional, flawless results by preventing uneven curing and speeding up the process, making it ideal for various resin projects, including silicone molds.

Informazioni sulla sicurezza

AVVERTIMENTO:

  • Always place the device on a stable, heat-resistant surface.
  • Ensure proper ventilation when working with resin.
  • Non immergere il dispositivo in acqua o altri liquidi.
  • Tenere fuori dalla portata dei bambini e degli animali domestici.
  • Scollegare il dispositivo quando non è in uso o prima di pulirlo.
  • Avoid placing flammable materials directly on or near the heating surface.

Cosa c'è nella scatola

  • OFFNOVA Resin Heating & Leveling Table x 1
  • Controllore x 1
  • Manuale x 1

Caratteristiche del prodotto

2-in-1 Curing & Leveling

This device combines fast resin curing with a leveling table. It features adjustable feet and a built-in bubble level to ensure an even surface, preventing uneven curing. The heating function efficiently cures resin, typically within 2-3 hours, for professional results.

OFFNOVA 2-in-1 Resin Heating Mat and Leveling Table showing adjustable height, level, time, and heat settings.

Image: The OFFNOVA 2-in-1 Resin Heating Mat and Leveling Table highlighting its adjustable height, built-in level, and control panel for time and heat settings.

Durable & Reliable Design

The resin curing board is constructed with a tempered glass panel, advanced carbon fiber heating elements, and a sturdy aluminum alloy base for enhanced durability. Non-slip pads and elevated feet protect your workspace from heat damage and ensure stability during use.

Sezione trasversale view of the OFFNOVA heating mat showing tempered glass, alloy heating elements, and aluminum alloy base.

Immagine: Un esploso view illustrating the durable construction of the OFFNOVA heating mat, including the tempered glass top, internal alloy heating elements, and robust aluminum alloy base.

Customizable Heating Modes

The device offers three temperature settings (122°F, 140°F, 158°F) and an adjustable 6-hour timer. This allows users to customize heat and curing time based on resin mold thickness and ambient conditions, ensuring consistent and flawless results.

Smart Timer & Alerts

When a curing time is selected, the remote control's countdown indicator updates hourly. The resin curing machine signals completion with three beeps, providing precise and user-friendly operation.

Perfect for Silicone Molds

This resin curing table not only improves efficiency but also guarantees flawless results for all resin projects. Its leveling design ensures even curing for intricate resin art and large epoxy projects, eliminating uneven or imperfect surfaces.

Impostare

  1. Disimballare il dispositivo: Carefully remove the heating mat and controller from the packaging.
  2. Posizionare su una superficie stabile: Position the OFFNOVA heating mat on a flat, stable, and heat-resistant surface.
  3. Collegare il controller: Plug the controller cable into the designated port on the heating mat.
  4. Livellare la superficie:

    Use the built-in bubble level to ensure the surface is perfectly horizontal. Rotate the adjustable foot pads (left and right) to raise or lower each corner until the bubble is centered within the level indicator.

    Three steps showing how to adjust the leveling feet of the OFFNOVA resin heating mat to center the bubble level.

    Image: A visual guide demonstrating the process of adjusting the leveling feet to achieve a perfectly horizontal surface, indicated by the centered bubble in the built-in level.

  5. Collegare all'alimentazione: Connect the power adapter to a suitable electrical outlet.

Video dimostrativo di installazione

Video: A demonstration of setting up the OFFNOVA 2-in-1 Resin Heating Table, including adjusting the leveling feet and preparing for use.

Istruzioni per l'uso

  1. Accensione: Press the power button on the remote controller to turn on the device.
  2. Seleziona la temperatura: Use the "HEAT" button on the remote to cycle through the three temperature settings: 122°F, 140°F, and 158°F. Choose the appropriate temperature for your resin type and mold thickness.
  3. Imposta timer: Use the "TIMER" button to select the desired curing time (up to 6 hours). The remote's indicator lights will show the selected duration.
  4. Place Molds: Carefully place your resin molds on the leveled heating surface. Ensure they are stable and do not obstruct the bubble level.
  5. Monitorare la polimerizzazione: The timer lights on the remote will update hourly. Once the curing cycle is complete, the machine will signal with three beeps.
  6. Spegni: After curing, press the power button to turn off the device and unplug it from the power source.

Controllore finitoview

Dettagliato view of the OFFNOVA remote controller showing power indicator, 6-hour timer settings, 4 temperature levels, timer adjustment button, heating adjustment button, and power button.

Image: A comprehensive diagram of the OFFNOVA remote controller, detailing all buttons and indicators for temperature and timer settings.

Time Tracking and Alerts

OFFNOVA heating mat with remote control showing timer settings and a bell icon indicating alerts.

Image: The OFFNOVA heating mat in use, with the remote control displaying active timer settings and a visual representation of the alert system.

Curing Efficiency Comparison

Comparison showing resin cured on the OFFNOVA heating board in 2 hours versus natural curing taking 12 hours, highlighting complete curing and leveling.

Image: A visual comparison demonstrating the significantly faster and more complete curing achieved with the OFFNOVA Resin Heating Leveling Board (2 hours) compared to natural curing (12 hours).

Manutenzione

  • Pulizia: Ensure the device is unplugged and completely cool before cleaning. Wipe the tempered glass surface with a soft, damp panno. Non usare detergenti abrasivi o solventi.
  • Magazzinaggio: Conservare il dispositivo in un luogo fresco e asciutto, lontano dalla luce solare diretta e dall'umidità quando non viene utilizzato.
  • Ispezione: Periodically check the power cord and controller for any signs of damage. If damage is found, discontinue use and contact customer support.

Risoluzione dei problemi

ProblemaPossibile causaSoluzione
Il dispositivo non si accende.Not plugged in; power outlet issue; controller not connected properly.Ensure power cord is securely plugged into a working outlet. Check controller connection.
La funzione di riscaldamento non funziona.Temperature not selected; timer not set; internal malfunction.Verify temperature setting on the controller. Ensure a timer duration is selected. If problem persists, contact support.
Resin is not curing evenly.Surface not level; incorrect temperature/time settings for resin type.Re-level the device using the adjustable feet and bubble level. Adjust temperature and time settings as per resin manufacturer's recommendations.
Timer alerts not sounding.Volume setting too low (if applicable); malfunction.Ensure the environment is quiet enough to hear the beeps. If no sound, contact support.

Specifiche

  • Modello: C1216
  • Dimensioni (L x P x A): 15.7 x 11.8 x 1 pollici
  • Peso: 4.97 libbre
  • Materiale: Vetro temperato, alluminio
  • Colore: Blizzard
  • Impostazioni della temperatura: 122°F, 140°F, 158°F (approx. 50°C, 60°C, 70°C)
  • Impostazioni timer: Fino a 6 ore
  • Fonte di energia: Presa elettrica standard
  • Produttore: OFFNOVA
  • Paese di origine: Cina
OFFNOVA heating mat with dimensions 15.7 inches by 11.8 inches and a thickness of 0.39 inches for the tempered glass.

Image: The OFFNOVA heating mat displaying its overall dimensions and the thickness of its high-strength tempered glass surface.

Garanzia e supporto

OFFNOVA products are designed for quality and reliability. For any questions, technical support, or warranty claims, please contact OFFNOVA customer service through the retailer where you purchased the product or visit the official OFFNOVA websito per le informazioni di contatto.

Si prega di conservare la prova d'acquisto ai fini della garanzia.

Visit the OFFNOVA Store on Amazon

© 2024 OFFNOVA. Tutti i diritti riservati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.