1. Introduzione

Thank you for choosing the VIVAX ACP-12CH35AEMI R32 12000 BTU Inverter Air Conditioner. This unit is designed to provide efficient cooling, heating, and dehumidification for your home or office. Featuring inverter technology, an eco-friendly R32 refrigerant, and high energy efficiency ratings (A++ for cooling, A+ for heating), this air conditioner ensures optimal comfort with reduced energy consumption. This manual provides essential information for the safe installation, operation, and maintenance of your new air conditioner.

2. Informazioni sulla sicurezza

Please read all safety warnings and instructions carefully before installing and operating this appliance. Keep this manual for future reference.

  • Installazione professionale: Installation, maintenance, and repair of this unit must be performed by qualified and authorized personnel. Improper installation can lead to electric shock, fire, or water leakage.
  • Alimentazione elettrica: Assicurarsi che l'alimentatore corrisponda alle specifiche dell'unità. Non utilizzare prolunghe o adattatori per prese multiple.
  • Refrigerante: Questa unità utilizza il refrigerante R32. L'R32 è un refrigerante leggermente infiammabile. Non forare né bruciare. Si prega di notare che i refrigeranti potrebbero non avere alcun odore.
  • Ventilazione: Assicurare una ventilazione adeguata durante l'installazione e la manutenzione.
  • Bambini e animali domestici: Tenere bambini e animali domestici lontani dall'unità durante il funzionamento e la manutenzione.
  • Pulizia: Scollegare sempre l'alimentazione prima di effettuare operazioni di pulizia o manutenzione.
  • Ostruzioni: Non bloccare l'ingresso o l'uscita dell'aria dell'unità interna o esterna.

3. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

  • VIVAX ACP-12CH35AEMI Indoor Unit
  • VIVAX ACP-12CH35AEMI Outdoor Unit (External unit required)
  • Telecomando
  • Manuale dell'utente (questo documento)
  • Installation Kit (Piping, wiring, drainage hose - may vary by region/installer)

4. Configurazione e installazione

The VIVAX ACP-12CH35AEMI is a split-system air conditioner, requiring both an indoor and an outdoor unit. Professional installation by a certified technician is mandatory to ensure proper functioning, safety, and warranty validity.

4.1. Linee guida generali per l'installazione

  • Posizionamento dell'unità interna: Scegliere una posizione che consenta una distribuzione uniforme dell'aria in tutta la stanza, lontano dalla luce solare diretta o da fonti di calore. Assicurarsi che vi sia spazio sufficiente intorno all'unità per la manutenzione e il ricircolo dell'aria.
  • Posizionamento dell'unità esterna: Install the outdoor unit in a well-ventilated area, away from obstacles that might impede airflow. Ensure it is placed on a stable, level surface and protected from extreme weather conditions.
  • Tubazioni e cablaggi: The refrigerant pipes and electrical wiring connecting the indoor and outdoor units must be installed according to local regulations and manufacturer specifications.
  • Drenaggio: Ensure proper drainage for condensate water from the indoor unit to prevent leaks.
VIVAX ACP-12CH35AEMI Indoor Unit

Image: The VIVAX ACP-12CH35AEMI indoor unit, showcasinil suo design elegante.

5. Istruzioni per l'uso

Your VIVAX air conditioner can be controlled using the included remote control or, optionally, via a smartphone app if the Wi-Fi module is installed.

5.1. Controllo remoto finitoview

The remote control allows you to access all functions of your air conditioner. Ensure the remote control has fresh batteries installed.

VIVAX Air Conditioner Remote Control

Image: The VIVAX air conditioner remote control, showing various buttons and the display.

5.2. Modalità operative di base

  • Modalità di raffreddamento (FREDDO): Sets the unit to cool the room. Adjust the temperature using the Up/Down arrows.
  • Heating Mode (CALORE): Sets the unit to heat the room (Heat Pump function). Adjust the temperature using the Up/Down arrows.
  • Dehumidification Mode (ASCIUTTO): Riduce l'umidità nella stanza senza variazioni significative della temperatura.
  • Modalità ventola (FAN): Fa circolare l'aria senza raffreddare o riscaldare. La velocità della ventola è regolabile.
  • Modalità automatica (AUTO): The unit automatically selects the operating mode (cooling, heating, or fan) based on the ambient temperature and your set temperature.

5.3. Funzioni avanzate

  • Impostazione della temperatura: Utilizzare il UP E GIÙ pulsanti per regolare la temperatura desiderata.
  • Velocità della ventola: Premere il tasto FAN button to cycle through different fan speeds (Auto, Low, Medium, High).
  • Funzione oscillazione: Premere il tasto SWING pulsante per regolare la direzione del flusso d'aria verticale o abilitare l'oscillazione continua.
  • Funzione timer: Set the unit to turn ON or OFF automatically after a specified period. Refer to the remote control section of the full manual for detailed timer settings.
  • Modalità risparmio: Optimizes operation for comfortable sleep by gradually adjusting temperature and fan speed.
  • Modalità ecologica: Reduces energy consumption by optimizing compressor operation.
  • Controllo Wi-Fi (facoltativo): If the optional Wi-Fi module is installed, download the VIVAX app to control your air conditioner remotely via smartphone. Follow the app's instructions for pairing.

6. Manutenzione

Una manutenzione regolare garantisce prestazioni ottimali e prolunga la durata del condizionatore. Scollegare sempre l'alimentazione elettrica prima di eseguire qualsiasi intervento di manutenzione.

6.1. Pulizia del filtro dell'aria

The VIVAX ACP-12CH35AEMI is equipped with an antimicrobial air filter. Clean the air filters every two weeks or more frequently depending on usage and air quality.

  1. Aprire il pannello frontale dell'unità interna.
  2. Rimuovere con cautela i filtri dell'aria.
  3. Clean the filters using a vacuum cleaner or wash them with lukewarm water (below 40°C) and a mild detergent.
  4. Risciacquare abbondantemente e lasciare asciugare completamente in una zona ombreggiata prima di reinstallarli. Non esporre alla luce solare diretta.
  5. Reinstallare i filtri asciutti e chiudere il pannello frontale.
Air conditioner with open panel showing cleanable filters

Image: An open indoor air conditioner unit revealing the removable and cleanable air filters.

6.2. Pulizia generale

  • Wipe the indoor unit's exterior with a soft, dry cloth. For stubborn dirt, use a damp panno con un detergente delicato, quindi asciugare.
  • Non utilizzare prodotti chimici aggressivi, detergenti abrasivi o solventi, poiché potrebbero danneggiare la superficie.
  • Ensure the outdoor unit's coils are free from debris (leaves, dust). If heavily soiled, professional cleaning is recommended.

6.3. Seasonal Checks

  • Before the cooling/heating season, check for any unusual noises or odors.
  • Ensure the drainage hose is clear and not blocked.
  • Verify that the outdoor unit is free from obstructions.

7. Risoluzione Dei Problemi

Prima di contattare l'assistenza, verificare i seguenti problemi comuni e le relative soluzioni:

ProblemaPossibile causaSoluzione
L'unità non si avviaNo power; Remote control batteries low; Timer set to OFFControllare l'alimentazione; sostituire le batterie; annullare l'impostazione del timer
Raffreddamento/riscaldamento insufficienteAir filters dirty; Temperature setting incorrect; Doors/windows open; Obstruction at air inlet/outletClean air filters; Adjust temperature; Close doors/windows; Remove obstructions
Perdita d'acqua dall'unità internaDrainage hose blocked or bent; Unit not levelCheck and clear drainage hose; Ensure unit is level (professional adjustment may be needed)
Rumore insolitoLoose parts; Foreign objects; Unit not installed properlyCheck for loose parts; Remove foreign objects; Contact professional for inspection
Il telecomando non funzionaBatteries low or incorrectly inserted; Obstruction between remote and unitReplace batteries; Ensure clear line of sight to indoor unit's receiver

Se il problema persiste dopo aver provato queste soluzioni, contattare un tecnico qualificato.

8. Specifiche

Technical specifications for the VIVAX ACP-12CH35AEMI R32 12000 BTU Inverter Air Conditioner:

CaratteristicaSpecificazione
MarcaVIVAX
Numero di modelloACP-12CH35AEMI
Capacità di raffreddamentoPotenza nominale: 12000 BTU
Capacità di riscaldamentoFunzionalità della pompa di calore
Efficienza energetica (raffreddamento)Ottimo
Efficienza energetica (riscaldamento)A+
SEER (rapporto di efficienza energetica stagionale)6.1
RefrigeranteR-32
Tipo di compressoreInverter (Rotary Scroll)
Dimensioni del prodotto (P x L x A)19.4P x 80.5l x 28.5H cm
Peso dell'articolo35 chilogrammi
Voltage220 Volt
Energia elettrica3.6 kW
Livello di rumore63 decibel
Tipo di filtroFiltro dell'aria antimicrobico
Metodo di controlloRemote Control, App (Optional Wi-Fi)
Area di coperturaFino a 35 metri quadrati
ColoreBianco
Materiale principaleMetallo
Tipo di installazioneSistema diviso
External Unit Required
Paese di origineCina

9. Garanzia e supporto

9.1. Garanzia del prodotto

This VIVAX air conditioner comes with a product warranty of 24 mesi from the date of purchase. The warranty covers manufacturing defects and malfunctions under normal use. Please retain your proof of purchase for warranty claims. The warranty may be voided by improper installation, unauthorized repairs, or misuse.

9.2. Assistenza clienti

For technical assistance, warranty claims, or service requests, please contact your authorized VIVAX dealer or the customer support channel provided at the point of purchase. When contacting support, please have your model number (ACP-12CH35AEMI) and purchase date ready.