OLTEANP UPS-TK1500W

Manuale utente del sistema di backup della batteria della pompa di sentina OLTEANP da 1500 W

Model: UPS-TK1500W

Marca: OLTEANP

1. Introduzione

The OLTEANP 1500W Sump Pump Battery Backup System is designed to provide continuous power to your sump pump during power outages, protecting your basement from flooding. This pure sine wave power inverter with a built-in charger automatically switches between grid power and battery power, ensuring reliable operation. It features an LCD screen remote controller for easy monitoring and multiple safety protections.

2. Informazioni sulla sicurezza

Leggere attentamente tutte le istruzioni di sicurezza prima dell'installazione e dell'uso. La mancata osservanza di queste istruzioni può causare scosse elettriche, incendi o lesioni gravi.

  • Garantire un'adeguata ventilazione intorno all'unità per evitare il surriscaldamento.
  • Do not expose the unit to water, rain, snow, or spray.
  • Connect the unit only to a 12V battery system.
  • Assicurarsi che tutti i collegamenti siano ben saldi e sicuri per evitare la formazione di archi elettrici.
  • Non smontare l'unità. Per qualsiasi intervento di manutenzione, rivolgersi a personale qualificato.
  • Keep away from flammable materials and gases.
  • Always wear appropriate personal protective equipment (PPE) when handling batteries and electrical connections.

3. Contenuto della confezione

Verificare che tutti gli articoli siano presenti nel pacco:

  • 1500W Sump Pump Battery Backup System (Main Unit)
  • Cavi della batteria (rosso e nero)
  • Manuale dell'utente (questo documento)
  • Telecomando con schermo LCD
  • Cavo di alimentazione
  • Accessories (e.g., wrench, earth wire)
OLTEANP 1500W Sump Pump Battery Backup System and included accessories

Image: The main unit of the OLTEANP 1500W Sump Pump Battery Backup System along with its remote controller, battery cables, and power cable.

4. Prodotto finitoview

The OLTEANP 1500W system integrates an inverter, charger, and automatic transfer switch into one compact unit. Key features include:

  • Uscita onda sinusoidale pura: Fornisce un'alimentazione pulita e stabile, adatta ai dispositivi elettronici sensibili.
  • Built-in 25A Battery Charger: Supports fast charging for various deep-cycle battery types (Lithium, AGM, Flooded/Wet).
  • Commutazione automatica: Seamlessly transitions from grid power to battery power (and vice-versa) within 12ms during outages.
  • Uscite multiple: Features 3 AC outlets, a 36W Type-C port, and a 5V/3.1A USB port.
  • LCD Remote Controller: Displays real-time battery status, AC output, and fault indicators.
  • Protezione di sicurezza multifunzionale: Includes overheat, short circuit, low voltage, overcharge, high voltage, overload, and earth wire protection.
Remote controller with LCD screen displaying battery and power status

Image: Close-up of the remote controller's LCD screen, showing battery charge, DC input voltage, uscita AC voltage, e cosatage. Fault indicators for overheat, overload, and short circuit are also visible.

Diagram of multi-functional safety protections

Image: Icons representing the multi-functional safety protections: High-Voltage Protection, Overload Protection, High-Temperature Protection, Smart IC, Low Voltage Protection, and Short-Circuit Protection.

Dettagliato view of the inverter's AC and DC side ports and features

Image: A detailed diagram labeling the various ports and features on the inverter, including USB Port, Fault LED, Power LED, Fully Charged Indicator, Battery Type Selection Button, ON/OFF switch, L, N, PE terminals, Earth wire, Remote Connection port, Negative Terminal, Cooling Fan, Positive Terminal, 120V AC Outputs (x3), Type-C Port, AC Fuse, and AC Charge Input.

5. Impostazione

The OLTEANP sump pump battery backup system is designed for easy installation with minimal wiring required.

5.1 Scelta di una posizione

  • Select a dry, well-ventilated area, away from direct sunlight, heat sources, and flammable materials.
  • Ensure sufficient space around the unit for proper airflow and cooling.
  • The unit can be placed flat or wall-mounted using the fixed holes on the side.

5.2 Collegamento della batteria

A 12V deep-cycle battery (not included) is required for operation. Ensure the battery is compatible with the system (Lithium, AGM, Flooded/Wet).

  1. Connect the red battery cable to the positive (+) terminal of the battery and the positive (+) terminal on the inverter.
  2. Connect the black battery cable to the negative (-) terminal of the battery and the negative (-) terminal on the inverter.
  3. Assicurarsi che tutti i collegamenti siano ben saldi e sicuri.

5.3 Collegamenti di ingresso e uscita CA

  1. Plug the provided AC power cable into the "AC Charge Input" port on the inverter and then into a standard wall outlet.
  2. Connect your sump pump(s) and other desired appliances (within the 1500W limit) to the 3 AC output sockets on the inverter.
  3. For additional charging, use the USB and Type-C ports as needed.
Diagram showing the inverter connected to a battery and a sump pump system

Image: A schematic illustrating the connection of the OLTEANP inverter to a 12V battery and a sump pump. It shows the AC charge input, 3 AC outlets, USB port, and Type-C port, with power flow indicated for charging the battery and powering the sump pump.

5.4 Collegamento del telecomando

  • Connect the remote controller cable to the "Remote Connection" port on the inverter. This allows for convenient monitoring and control from a distance.

5.5 Selezione del tipo di batteria

Before turning on the inverter, select the correct battery type using the switches on the unit. Refer to the table below for settings:

Table for selectable battery types and corresponding switch settings

Image: A table showing the switch settings (1 and 2, ON/OFF) for different battery types (GEL, AGM/SLA, Flooded/Wet, LiFePO4) along with their Bulk/Absorption and Float voltage impostazioni.

Battery Type Selection Settings
Cambia 1Cambia 2Tipo di batteriaVolume di massa/assorbimentotageVolume galleggiantetage
SPENTOSPENTOGEL14.2V13.6V
SPENTOONAGM/SLA14.4V13.6V
ONSPENTOFlooded/Wet14.7V13.6V
ONONLiFePO414.6V14.6V

6. Istruzioni per l'uso

6.1 Accensione iniziale

  1. After all connections are made and the battery type is selected, turn on the main power switch on the inverter.
  2. The Power LED (Green) should illuminate.
  3. The LCD remote controller will display current battery voltage, uscita CA e wattage.

6.2 Normal Operation (Grid Power Available)

When grid power is available, the system operates in charging mode:

  • The connected sump pump(s) and other devices will be powered directly by the grid.
  • The built-in 25A charger will automatically charge the connected 12V battery. The "Fully Charged Indicator" will show the charging status.
  • The LCD remote controller will show the charging status and battery voltage.

6.3 Potenza in uscitatage Operation (Battery Backup)

In caso di mancanza di correntetage, the system automatically switches to battery power:

  • The system will detect the loss of grid power and instantly switch to inverter mode within 12ms.
  • The sump pump(s) and other connected devices will continue to operate, powered by the battery through the inverter.
  • The LCD remote controller will display the battery voltage and the power being drawn by the connected loads.
  • When grid power is restored, the system will automatically switch back to grid power and resume charging the battery.
Image showing the inverter powering multiple sump pumps

Image: A visual representation of the OLTEANP 1500W system connected to and powering three sump pumps simultaneously, demonstrating its capacity to handle multiple loads up to 1500 watts.

6.4 Utilizzo delle porte USB e Type-C

The USB (5V/3.1A) and Type-C (36W) ports can be used to charge compatible electronic devices during both grid and battery operation.

7. Manutenzione

Regular maintenance ensures the longevity and optimal performance of your OLTEANP Sump Pump Battery Backup System.

  • Pulizia: Mantenere l'unità pulita e libera da polvere e detriti. Utilizzare un panno asciutto e morbido per la pulizia. Non utilizzare detergenti liquidi.
  • Ventilazione: Ensure the cooling fans and vents are not obstructed. Periodically check for dust buildup and clean if necessary.
  • Stato della batteria: Regularly check the battery terminals for corrosion and ensure connections are tight. For flooded batteries, check electrolyte levels as per battery manufacturer's instructions.
  • Prova di funzionalità: Periodically test the system by simulating a power outage (e.g., by unplugging the AC input) to ensure it switches to battery power correctly.
  • Magazzinaggio: If storing the unit for an extended period, ensure the battery is fully charged and disconnect it from the inverter. Store in a cool, dry place.

8. Risoluzione Dei Problemi

This section addresses common issues you might encounter with your OLTEANP Sump Pump Battery Backup System.

ProblemaPossibile causaSoluzione
No power output from AC outlets.
  • Inverter is OFF.
  • La batteria è scarica o non è collegata.
  • Protezione da sovraccarico attivata.
  • Il LED di errore è acceso.
  • AC input power is off.
  • Assicurarsi che l'interruttore ON/OFF sia in posizione ON.
  • Controllare i collegamenti della batteria e il livello di carica.
  • Ridurre il carico collegato all'inverter.
  • Check the LCD remote controller for specific fault codes and refer to the manual for resolution.
  • Verify grid power is available and AC input cable is securely plugged in.
Batteria non in carica.
  • AC input power is off or cable loose.
  • Incorrect battery type selected.
  • Battery cables loose or corroded.
  • La batteria è difettosa.
  • Check AC input power and cable connection.
  • Verify the battery type selection switches are set correctly for your battery.
  • Inspect and tighten battery cable connections. Clean any corrosion.
  • Test the battery with a battery tester. Replace if faulty.
L'inverter si spegne frequentemente.
  • Sovraccarico.
  • Surriscaldamento.
  • Basso volume della batteriatage.
  • Ridurre il peso totaletage dei dispositivi collegati.
  • Ensure proper ventilation; clean cooling fans if necessary.
  • Charge the battery. Ensure battery capacity is sufficient for the load.
Inverter does not turn on automatically after full battery discharge and AC power returns.
  • This is a known operational characteristic after a complete battery drain.
  • After the battery has recharged, manually turn the inverter ON using the main power switch or the remote controller.

9. Specifiche

CaratteristicaDettaglio
ModelloUPS-TK1500W
Potenza continua1500W
Potenza di picco3000W
Ingresso volumetage12V CC
Volume di uscitatage120 V CA
Forma d'onda di uscitaOnda sinusoidale pura
Corrente del caricabatteria25A
Tempo di trasferimento12 millisecondo
Uscite CA3 x 120V AC Outlets
Porta USB5V/3.1A
Porta di tipo C36W
Dimensioni (L x P x A)14.48 x 7.91 x 4.49 pollici (368 x 201 x 114 mm)
Peso dell'articolo11.75 libbre
MaterialeMetallo
ColoreBlu
Dimensions and included accessories of the OLTEANP 1500W Sump Pump Battery Backup System

Image: A diagram illustrating the dimensions of the main inverter unit and showing all included accessories: power cable, remote control, battery cables (red and black), and additional accessories like a wrench.

10. Garanzia e supporto

The OLTEANP Sump Pump Battery Backup System comes with a Garanzia di 12 mesi dalla data di acquisto.

For technical support, warranty claims, or any questions regarding your product, please contact OLTEANP customer service through the retailer's platform or the official OLTEANP website. Please have your model number (UPS-TK1500W) and purchase date available when contacting support.

Per maggiori informazioni, potete visitare il sito Negozio OLTEANP su Amazon.

© 2025 OLTEANP. Tutti i diritti riservati.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.