TAMBURO

DRUMMOND 1 HP Shallow Well Pump & Tank User Manual

Modello: 63407

1. Introduzione

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank system. This system is designed to provide a reliable and consistent water supply for various domestic applications, including kitchens, bathrooms, and outdoor use.

Key features of your pump system include:

  • Motore ad alte prestazioni: Delivers powerful performance with a flow rate of 950 GPH.
  • 5-Gallon Pressure Tank: Stores water to ensure consistent pressure and reduce pump cycling.
  • Pressostato automatico: Maintains optimal water pressure, activating at 30 PSI and deactivating at 50 PSI.
  • Costruzione in acciaio inossidabile: Ensures corrosion resistance and long-lasting durability.
  • Installazione semplice: Designed for straightforward setup and maintenance.

2. Informazioni sulla sicurezza

WARNING: Read and understand all safety instructions before operating this pump. Failure to follow these instructions may result in electric shock, fire, serious injury, or property damage.

  • Always disconnect power before servicing or performing maintenance on the pump.
  • Assicurarsi che la pompa sia correttamente collegata a terra per evitare scosse elettriche.
  • Non utilizzare la pompa con cavi o spine danneggiati.
  • Mantenere tutti i collegamenti elettrici asciutti e protetti dall'acqua.
  • Do not pump flammable or corrosive liquids. This pump is designed for water only.
  • Assicurare un'adeguata ventilazione attorno alla pompa per evitare il surriscaldamento.
  • Proteggere la pompa dalle temperature gelide per evitare danni.

3. Prodotto finitoview

The DRUMMOND Shallow Well Pump system consists of a 1 HP stainless steel pump head mounted on a 5-gallon steel pressure tank. It includes an integrated pressure control switch and a pressure gauge for monitoring system pressure.

Pompa e serbatoio per pozzi bassi in acciaio inossidabile da 1 HP DRUMMOND

Figure 1: DRUMMOND 1 HP Stainless Steel Shallow Well Pump and Tank system. This image shows the green-colored pressure tank, the stainless steel pump head, the electric motor, and the pressure control switch with an attached pressure gauge.

4. Configurazione e installazione

4.1. Selezione del sito

Choose a location that is dry, well-ventilated, and protected from freezing temperatures. The pump should be placed as close to the water source as possible to minimize suction lift. Ensure the surface is level and stable to support the pump's weight.

4.2. Collegamenti idraulici

  1. Linea di aspirazione: Connect a 1-inch intake pipe from your water source (well) to the pump's suction port. Ensure all connections are airtight to prevent air leaks, which can cause the pump to lose prime. Use thread sealant tape on all threaded connections.
  2. Linea di scarico: Connect a 1-inch discharge pipe from the pump's discharge port to your household plumbing system. Install a shut-off valve on the discharge line to isolate the pump for maintenance.
  3. Valvola di ritegno: It is recommended to install a check valve on the suction line just above the water level in the well to maintain prime.

4.3. Connessione elettrica

CAUTION: Electrical work should be performed by a qualified electrician in accordance with all local and national electrical codes.

  • La pompa richiede un'alimentazione a 120 V CA.
  • Ensure the circuit is protected by a properly sized circuit breaker or fuse (10A minimum).
  • Connect the pump to a dedicated, grounded electrical outlet.

4.4. Adescamento della pompa

Prima della messa in funzione iniziale, la pompa deve essere adescata:

  1. Remove the priming plug located on top of the pump housing.
  2. Fill the pump housing completely with clean water using a funnel until water overflows.
  3. Riposizionare saldamente il tappo di adescamento.
  4. Open a faucet in your house to allow air to escape the system during startup.

5. Istruzioni per l'uso

5.1. Avvio iniziale

After priming and ensuring all connections are secure:

  1. Accendere l'alimentazione alla pompa.
  2. The pump will start and begin to draw water.
  3. Allow the pump to run until a steady stream of water flows from the open faucet and the pressure gauge reaches 50 PSI, at which point the pump will automatically shut off.
  4. Chiudere il rubinetto. Il sistema è ora pronto per l'uso.

5.2. Funzionamento automatico

The integrated pressure control switch manages the pump's operation. When water is drawn from the system and the pressure drops to 30 PSI, the pump will automatically turn on. When the pressure reaches 50 PSI, the pump will turn off. This ensures a consistent water supply without manual intervention.

6. Manutenzione

6.1. Controlli regolari

  • Periodically check for leaks around plumbing connections.
  • Monitor the pressure gauge to ensure the pump is cycling correctly within the 30-50 PSI range.
  • Ispezionare il cavo di alimentazione per eventuali segni di danneggiamento.

6.2. Pressure Tank Air Charge

The pressure tank contains an air bladder that helps maintain system pressure. Over time, the air charge may decrease. Check the air pressure in the tank annually (with the pump off and system drained) using a tire gauge. The pre-charge pressure should typically be 2 PSI below the pump's cut-in pressure (e.g., 28 PSI for a 30 PSI cut-in).

6.3. Preparazione per l'inverno

If the pump is installed in an area subject to freezing temperatures, it must be winterized to prevent damage:

  1. Togliere l'alimentazione alla pompa.
  2. Drain all water from the pump housing and plumbing lines by opening drain plugs and faucets.
  3. Store the pump in a warm, dry location if possible, or ensure all water is completely removed from the system.

7. Risoluzione Dei Problemi

ProblemaPossibile causaSoluzione
La pompa non si avviaNo power; tripped circuit breaker; faulty pressure switch; seized motor.Check power supply; reset breaker; inspect/replace pressure switch; consult technician.
La pompa funziona ma non c'è acquaPump not primed; air leak in suction line; low water level in well; clogged intake.Re-prime pump; check all suction connections for leaks; verify well water level; clear intake.
Bassa pressione dell'acquaPartially clogged lines; low air charge in tank; worn pump components.Inspect/clear lines; check/adjust tank air pressure; consult technician for pump repair.
La pompa va in ciclo troppo frequentementeLow air charge in tank; waterlogged tank; small leak in system.Check/adjust tank air pressure; inspect tank bladder; check plumbing for leaks.

8. Specifiche

CaratteristicaDettaglio
Potenza1 CV
Portata950 GPH (15.83 galloni al minuto)
Sollevamento massimo della testa115.5 piedi
Sollevamento di aspirazione26 piedi
Impostazioni del pressostato30 PSI On / 50 PSI Off
Capacità del serbatoio5 galloni
Dimensione ingresso / uscita1 pollici
Fonte di alimentazione120V AC, Corded Electric
Amprabbia10A
MaterialeStainless Steel (Pump), Steel (Tank)
Peso dell'articolo35.65 libbre
Numero di modello63407
CertificazioniETL, UL

9. Garanzia e supporto

Specific warranty terms and customer support contact information are not provided within this manual. Please refer to the product packaging, original purchase documentation, or the manufacturer's official website for detailed warranty information and technical support contacts.

For general inquiries or assistance, you may also contact the retailer from whom you purchased this product.

© 2024 DRUMMOND. All rights reserved.

Questo manuale è soggetto a modifiche senza preavviso.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.